光谱学与光谱分析 |
|
|
|
|
|
Infrared Spectroscopy Application based on Trigger Sampling Method and Phase Correction |
LI Yan1, 2, GAO Min-guang1, XU Liang1*,LI Sheng1,LI Xiang-xian1,YE Shu-bin1, 2,LIU Jian-guo1 |
1. Key Laboratory of Environmental Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China2. University of Science and Technology of China, Hefei 230026, China |
|
|
Abstract Fourier transform infrared spectrometer can be realized in high temperature flue gas multicomponent measurement at the same time, has wide application prospects in the field. And one of the important factors to determine the success of application, lies in the measuring system of infrared interference figure sampling phase error control. This paper discusses the main reasons of the appearance of phase error in the system, through the analysis of Helium-neon laser interference signal zero uniformity, illustrates the produce phase error is the main reason of the laser signal and reference signal phase difference. At the meantime, the quantitative analysis of the phase error influence on instrument signal to noise ratio (SNR), also the Mertz phase correction method for the instrument improves the thousands of times of the original signal to noise ratio. And the related experiment, the experimental results show that the system based on the interference figure sampling method satisfy the needs of high temperature flue gas measurements.
|
Received: 2014-06-11
Accepted: 2014-10-15
|
|
Corresponding Authors:
XU Liang
E-mail: xuliang@aiofm.ac.cn
|
|
[1] Qian Weikang,Mei Junhui,Qian Jianqiu. Applied Mechanics and Materials, 2013,421: 468. [2] XIE Pin-hua, LIU Wen-qing, ZHENG Zhao-hui, et al(谢品华,刘文清,郑朝辉,等). Acta Photonica Sinica(光子学报),2000,29(3): 271. [3] CHEN Dai-sheng, ZHANG Li-jun, BAO Jian-guo(陈代胜,张莉君,鲍建国). Envitonmental Science and Technology(环境科学与技术),2007, 30(9): 50. [4] LIU Zhi-ming, GAO Min-guang, ZHANG Tian-shu, et al(刘志明,高闽光,张天舒,等). Infrared Technology(红外技术),2007, 29(4): 243. [5] Schutze C, Lau S, Reiche N, et al. Energy Procedia,2013, 37: 4276. [6] ZHANG Min-juan, ZHANG Ji-long, WANG Zhi-bin, et al(张敏娟,张记龙,王志斌,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2012, 32(5): 1203. [7] Peter R Griffiths, James A de Haseth. Fourier Transform Infrared Spectrometry, Second Edition. John Wiley & Sons, 2007. 56. [8] Lawrence Mertz. Correction of Phase Errors in Interferograms Applied Optics, 1963, 12(2): 1332. [9] XING Ting, WANG Mo-chang, GONG Hui-xing(刑 廷,王模昌,龚惠兴). Acta Optica Sinica(光学学报),1999,19(3): 355. [10] Robert Furstenberg, Jeffrey O. Vibrational Spectroscopy, 2006, 42: 226. [11] Michael L Forman. Spectroscopy Optical Sciety of America,1966, 56(1): 56. [12] Avishai Ben-David,Agustin Ifarraguerri. Optical Society of America,2002, 41(6): 1181. [13] LI Sheng, GAO Min-guang, ZHANG Yu-jun, et al(李 胜,高闽光,张玉钧,等). Journal of Atmospheric and Environmental Optica(大气与环境光学学报), 2011, 6(3): 224. [14] Griffiths P R. Science, 1983, 222(4621): 297. |
[1] |
LIU Yuan-yuan1, CHEN Jian-jun2, QIU Bo1*, FAN Xiao-dong1, WEI Shi-ya1, SONG Tao1, DUAN Fu-qing3*. A Processing Method for Low SNR Repetitive Observation Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2311-2314. |
[2] |
LI Xiao-nan1, LIU Guo-qiang1, 2, HU Li-li1. Research on Nuclear Magnetic Resonance High-Quality Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(05): 1358-1361. |
[3] |
WANG Xin*, HE Hao, FAN Xian-guang, TANG Ming. Signal Processing Method for Raman Spectra Based on Matching Pursuit[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(01): 93-98. |
[4] |
SUN Jian-zhong1,2, ZHANG Le2*, GAO Fei1, LI Jiu-sheng1. Quality Improvement and Noise Reduction of Terahertz Continuous Wave Imaging[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(11): 3343-3346. |
[5] |
RAO Zhi-min, HUA Deng-xin, HE Ting-yao*, WANG Qiang, LE Jing. Performance Analysis of Double Wavelength Fluorescence Lidar in Detecting Atmospheric Biological Aerosols[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2804-2808. |
[6] |
WANG Huan1,2, WANG Yong-zhi1, ZHAO Yu1, ZHU Li1, YIN Li-hui1*. Latest Methods of Fluorescence Suppression in Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2050-2056. |
[7] |
LIANG Zhen-jiang, LIU Hai-xia*, LIU Kai-ming, NIU Yan-xiong, YIN Yi-heng . The Analysis of Microcavity-Integrated Graphene Photodetector’s SNR Based on 1.06 μm [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(02): 356-360. |
[8] |
LI Shan, CHEN Yuan-yuan*, WANG Zhi-bin, ZHANG Min-juan, JING Ning . Photo-Elastic Modulation Fourier Transform Spectrum Phase Correction and DSP Implementation [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(02): 374-378. |
[9] |
WANG Yu-tian, YANG Zhe, HOU Pei-guo*, CHENG Peng-fei, CAO Li-fang . Research on Spectroscopy Spectrum De-Noising of Mineral Oil Based on Lifting Scheme Wavelet Transform [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2144-2147. |
[10] |
Lü Jin-guang1, LIANG Jing-qiu1, LIANG Zhong-zhu1*, TIAN Chao1, 2, QIN Yu-xin1. Analysis and Design of Interference Imaging System in Fourier Transform Imaging Spectrometer Based on Multi-Micro-Mirror[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1554-1559. |
[11] |
HE Xiang, LENG Chun-bo, ZHANG Yun-hong*. A Comparison of Heterogeneous Reaction Kinetics of Oleic Acid Thin Film and Oleic Acid Coated Flyash with Ozone Using Vacuum FTIR[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1576-1580. |
[12] |
LI Wen-chao2, MENG Xiao-yun1, PIAO Rui-qi1, ZHAO Jing-jing1, LI Zhi-quan1*, TONG Kai1, GU Er-dan1 . Brand-New Ge20Ga5Sb10S65 Prism Biosensor Based on Inverted SPR [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(02): 571-576. |
[13] |
XIU Lian-cun1, 2, 3, ZHENG Zhi-zhong1, 2, 3, YIN Liang1, 2, 3, CHEN Chun-xia1, 2, 3, YU Zheng-kui1, 2, 3, HUANG Bin1, 2, 3, ZHANG Qiu-ning1, 2, 3, XIU Xiao-xu4,GAO Yang1, 2, 3. Research on Assessment Methods of Spectrum Data Quality of Core Scan [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(08): 2352-2356. |
[14] |
WANG Xin1, LI Yan1, WEI Hao-yun1, REN Li-bing1, QI Yang2 . FTIR Noise Calibration in Quantitative Estimate of VOCs Concentration [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(05): 1199-1202. |
[15] |
WANG Shuang1, 2, XIANGLI Bin3, LI Li-bo1, 2, PI Hai-feng1, 2 . Research of Spectrum Signal-to-Noise Ratio of Large Aperture Static Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(03): 851-856. |
|
|
|
|