光谱学与光谱分析 |
|
|
|
|
|
Determination of Arsenic in Food Package Aluminum by Ultrasound Assisted Solid Phase Extraction/ICP-AES |
QIN Wen-xia, GONG Qi*, LI Min, DENG Li-xin, MO Li-shu, LI Yan-lin |
School of Chemistry and Chemical Engineering,Guangxi University,Nanning 530004,China |
|
|
Abstract Determination of arsenic in pure aluminum by inductively coupled plasma atomic emission spectrometry was interfered by aluminum matrix. The experiment showed that when the mass concentration of Al was greater than or equal to 5 000 times the As in the test solution, the measurement error was greater than 5%. In order to eliminate the interference, strong acid cation exchange fiber (SACEF) was used as solid phase extraction agent to adsorb Al3+. The extraction conditions included amount of SACEF, extraction time, temperature and pH were investigated. The optimal extraction conditions were that 0.900 0 g SACEF was used to extract the aluminum from the sample solution of pH 2.0 at 55 ℃ for 5 min with the ultrasonic assist, and in this case, the arsenic in the form of arsenic acid was not extracted and left in the solution for the determination. The results showed that after treating 10.00 mL test solution containing 1.00 μg arsenic and 20.0 mg aluminum, arsenic did not lose. The mass concentration of residual aluminum in the raffinate was about 2 000 times the As, which had not interfered the determination of arsenic. The detection limit (3 s) was 0.027 μg·mL-1 and quantification limit (10 s) was 0.091 μg·mL-1. The proposed method was successfully applied to the separation and determination of arsenic in the synthetic samples, the aluminum cans and the barbecue aluminum foil. Recovery was in the range of 98.3%~105% and RSD (n=3) was in the range of 0.1%~4.3%. The results showed that the content of arsenic in the aluminum cans and the aluminum barbecue foil was below the limited value of national standard (GB/T 3190—2008).
|
Received: 2014-03-31
Accepted: 2014-06-18
|
|
Corresponding Authors:
GONG Qi
E-mail: gongqi@gxu.edu.cn
|
|
[1] GB/T 3190—2008. Wrought Aluminum and Aluminum Alloy——Chemical Composition (变形铝及铝合金化学成分). Beijing:Standards Press of China(北京:中国标准出版社),2008. [2] Hassler J, Barth P, Richter S, et al. Journal of Analytical Atomic Spectrometry, 2011, 26(12): 2404. [3] CHENG Yong, YUAN Jin-hong, PENG Hui-xian(成 勇,袁金红,彭慧仙). Chinese Journal of Inorganic Analytical Chemistry(中国无机分析化学), 2013, 3(4): 52. [4] Palkendo J A, Kovach J, Betts T A. Journal of Chemical Education, 2014, 91(4): 579. [5] Wei Y H, Zhang J Y, Zhang, D W, et al. Food Chemistry, 2014, 159: 507. [6] Gong Q, Wei X L, Wu J N, et al. Journal of Analytical Atomic Spectrometry, 2012, 27(11): 1920. [7] ZHOU Xi-lin, ZHANG Hong, WANG Ya-sen, et al(周西林,张 宏,王亚森,等). Metallurgical Analysis(冶金分析), 2013, 33(4): 64. [8] Matsumiya H, Sakane Y, Hiraide M. Analytica Chimica Acta, 2009, 653(1): 86. [9] Cheng Y. Applied Mechanics and Materials, 2013, 271: 222. [10] HU Xuan, LI Yue-ping, SHI Lei(胡 璇,李跃平,石 磊). Metallurgical Analysis(冶金分析), 2014, 34(4): 17. [11] Wiltsche H, Günther D. Analytical and Bioanalytical Chemistry, 2011, 399(6): 2167. [12] Kovacs R, Schlosser S, Staub S P, et al. Journal of Analytical Atomic Spectrometry, 2009, 24(4): 476. [13] ZHANG Xiao-hong, HANG Wei, LI Qing-ping(张小红,杭 薇,李庆平). Liferatue and Information on Preventine Medicine(预防医学文献信息), 2004, 10(1): 68. [14] ZHI Hong-feng, SUN Ye, YANG Liu-hua(支红峰,孙 烨,杨柳桦). Chinese Journal of Health Laboratory Technology(中国卫生检验杂志), 2011, 21(9): 2172. [15] ZHANG Lin, LE Ai-shan, WANG Chang-zhao, et al(张 遴,乐爱山,王昌钊,等). Physical Testing and Chemical Analysis Part B: Chemical Analysis(理化检验-化学分册), 2009,45(10): 1197. |
[1] |
CHEN Ji-wen1, XU Tao2, LIU Wei2, FANG Zhe1, QU Hua-yang1*, LIANG Yuan1, HU Xue-qiang1, LIU Ming-bo1. On-Line Determination of Light-Rare Earth Distribution by Energy Dispersive-X-Ray Fluorescence[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2284-2289. |
[2] |
LIU Ming1, ZHAO Jing2*, WU Tai-xia4, ZHANG Li-fu4, TANG Hong-ying5, LU Xiao-zuo2, LI Gang3. Separation of Tongue Coat and Tongue Proper Based on Optical Spectrum Dissimilarity Index Using Double-Wavelength Ratio[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(06): 1798-1803. |
[3] |
LIU Jia, LIU Bing-bing, HAN Mei, JIA Na, ZHANG Chen-ling*. Methodology Research for Determination of Total Phosphorus in Water by Inductively Coupled Plasma-Atomic Emission Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(06): 1880-1883. |
[4] |
YANG Fen1, 2, 3, XIE Shao-wen 1, 2, 3, WEI Chao-yang1, 2*, LIU Jin-xin1, 2, 3. Effects of Methanol Addition on Arsenic Speciation Analysis with HPLC-ICP-MS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(06): 1884-1888. |
[5] |
CHEN Hua-zhou1, 2, XU Li-li3, CAI Ken4*, LIU Zhen-yao2, 5, CHEN An1, LIANG Yuan-yuan2. Performance Diagnosis of ICP-AES Combined with SVDV Technology for Quality Analysis of Drinking Water[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(05): 1558-1562. |
[6] |
DONG Xiang-cheng1, YUAN Ping2*. Calculating the Electron Temperature of Lightning Channel Based on the Continuous Radiation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(04): 1209-1212. |
[7] |
NAN Wei-gang1, 2, 3, Yoshihiro Deguchi2*, WANG Huan-ran1, LIU Ren-wei1, 2, Akihiro Ikutomo2, WANG Zhen-zhen1, 2. Reduction of CO2 Effect on Unburned Carbon Measurement in Fly Ash Using LIBS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(01): 258-262. |
[8] |
NIE Li-xing1, ZHANG Ye2, ZHU Li1, DAI Zhong1, MA Shuang-cheng1*. Fast and Nondestructive Analysis of Content of Mercury and Arsenic and Homogeneity of Niuhuang Qingxin Pills by Portable X-Ray Fluorescence Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3225-3228. |
[9] |
WANG Jin-lei1, 2, QIAN Jun-min2, LI Bo1, LUO Lin1*, SUN Bao-lian1, XU Wei-jun2, CUI Ning2. Chloroformylation-Separation of Matrix and Determination of Trace Impurities in High Purity Chromium by ICP-MS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2896-2899. |
[10] |
SHEN Ya-ting1, LI Ying-chun1, SUN Meng-he1,2, HE Yu-jun1,2, WANG Yan-fei1,2, LIN Ya-jie1,2. Studies on Characteristics on a Combined Wavelength and Energy Dispersion X-Ray Fluorescence Spectrometer and Determinations of Major, Minor and Trace Elements in Soils around a Mining Area[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2216-2224. |
[11] |
LI Yi-ke, FENG Ting, DENG Sui-min, WANG Xiang-feng, XIE Meng-xia*. Development of Magnetic and Fluorescent Immune Sensors for the Detection of Alpha Fetoprotein[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(06): 1667-1672. |
[12] |
ZHANG Wen-li1, 2, 3, LONG Ping1, 2, 3*, WU Jian1, 2, 3, CHEN Xiu-min1, 2, 3, XIONG Heng1, 2, 3, YANG Bin1, 2, 3. Determination of Sulfur in Solid and Solution of Phosphate Ore Pulp Flue Gas Desulfurization Agent with ICP-AES[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(05): 1535-1539. |
[13] |
TIAN Meng-jing1, MA Xiao-ling1, JIA Jia1, QIAO Yu1, WU Ting-yan1, LI He-xiang1, LIU Ying1,2*. Study of Residents’ Exposure to Arsenic Near the Yellow River Gan-Ning-Meng Reaches Using Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(05): 1628-1633. |
[14] |
MI Hai-peng1, ZHU Hong-ming1, LI Gen-rong1, YU Xiang1, MA Bing-bing2, ZHOU Xi-lin2, WANG Ya-sen2, SU Zhong-hua2, DENG Xiong2. Determination of Pb, Cr, Cd, and As in Aluminum-Plastic Packaging Materials via Inductively Coupled Plasma-Mass Spectrometry with Microwave Digestion[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(02): 646-650. |
[15] |
QI Li-jie, WANG Ying*, MENG Qing-zhu, ZHAO Zhen . Study on the Element Composition of Ancient Fossils and Meteorites [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(01): 247-249. |
|
|
|
|