光谱学与光谱分析 |
|
|
|
|
|
Study on the Advanced Schwarzschild Imaging Spectrometer with High Resolution in Broadband |
LIU Jian-fang |
Jilin University, Changchun 130031, China |
|
|
Abstract The Schwarzschild optical structure was studied for the application of imaging spectrometer. The perfect astigmatism-corrected condition was obtained based on the analysis of the astigmatism of the Schwarzschild structure. The structure was advanced in the paper. The Schwarzschild imaging spectrum system is composed of two Schwarzschild structures, which are the collimating mirror-convex mirror and the convex mirror-focusing mirror. The calculation was given to present the parameters of the imaging spectrum system. An example of the imaging spectrum system in the waveband of 340~500 nm was designed and proved our design theory. The solution of the initial optimum structure was designed by our theory and simulated. A system with NA 1.25, of which the modulation transfer functions (MTF) of all fields of view are more than 0.58 in the waveband in the required Nyquist frequency (20 lp·mm-1), is presented in the paper. The form of the design structure can be changed as C-T system, Ebert-Fastie system and Offner system. The result also certificated that the optical system theory can be applied to the small scale imaging spectrometer with high resolution and spectral broadband.
|
Received: 2013-02-04
Accepted: 2013-04-28
|
Corresponding Authors:
LIU Jian-fang
E-mail: liujianfang125@163.com
|
|
[1] ZHENG Yu-quan, WANG Hui, WANG Yi-fan(郑玉权, 王 慧, 王一凡). Optics and Precision Engineering(光学精密工程), 2009, 17(11): 2629. [2] Voropai E S, Gulis I M, Kupreev A G. Appl. Spectrosc., 2008, 75: 150. [3] Austin D R, Witting T, Walmsley I A. Appl. Opt., 2009, 48: 3846. [4] Xue Q, Wang S, Lu F. Appl. Opt., 2009, 48: 11. [5] Lee K S, Thompson K P, Rolland J P. Opt. Express, 2010, 18: 23378. [6] Prieto-Blanco X, Montero-Orille C, Couce B, et al. Opt. Express, 2006, 14(20): 9158. [7] Prieto-Blanco X, Montero-Orille C, et al. Opt. Express, 2010, 18(12): 12756. [8] Rosendahl G R. J. Opt. Soc. Am., 1962, 52:412. [9] Wetherell W B, Rimmer M P. Appl. Opt., 1972, 11:2817. [10] Budano A, Flora F, Mezi L. Appl. Opt., 2006, 45:4254. |
[1] |
LI Xin-quan1, 2,ZHANG Jun-qiang1, 3*,WU Cong-jun1,MA Jian1, 2,LU Tian-jiao1, 2,YANG Bin3. Optical Design of Airborne Large Field of View Wide Band Polarization Spectral Imaging System Based on PSIM[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 250-257. |
[2] |
LI Ming, QIN Kai*, ZHAO Ning-bo, TIAN Feng, ZHAO Ying-jun. Study on the Relationship Between Black Soil Emissivity Spectrum and Total Potassium Content Based on TASI Thermal Infrared Data[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2862-2868. |
[3] |
LIU Jia-nan1, 2*, CUI Ji-cheng1, YIN Lu1, 2, SUN Ci1, CHEN Jian-jun1, 2, ZHANG Rui1, 2, LIU Jian-li1, 2. Analysis and Design of Pre-Imaging System of Integral Field Imaging Spectrometer Based on Lenslet Array[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3269-3272. |
[4] |
ZHAO Shou-jiang1, YANG Bin1, JIAO Jian-nan2, YANG Peng1, WU Tai-xia3*, WANG Xue-qi1, YAN Lei1*. Using a Polarization Method to Reduce the Vegetation Inversion Error Caused by Strong or Weak Reflection Intensity[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3315-3320. |
[5] |
ZHANG Quan1, 2, HUANG Shu-hua1*, TIAN Yu-ze1, 2, LU Yue-lin1, 2, ZHAO Min-jie1, ZHOU Hai-jin1, ZHAO Xin1, WANG Yu1, SI Fu-qi1. Noise Analysis and Processing Method of Environment Monitoring Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(09): 2976-2981. |
[6] |
LIU Xiang-lei1,2, LIU Yang-yang1*, FANG Yu1, PEI Lin-lin1, Lü Qun-bo1. Optical Design of Large Relief Large Relative Apertureand High Resolution Modified Dyson Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3908-3912. |
[7] |
GAO Jian-hua1,2, LIANG Jing-qiu1, Lü Jin-guang1*, LIANG Zhong-zhu1, QIN Yu-xin1, WANG Wei-biao1. A Stepped Mirror Based Temporally and Spatially Modulated Imaging Fourier Transform Spectrometer: Principle and Data Processing[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3932-3939. |
[8] |
LI Shi-wei1,2, WANG Zhao-ba1,2, ZHANG Rui1,2,WANG Zhi-bin1,2,3. Spectral Measurements Based on Difference Frequency Modulation of Two PEMs Modulators[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2966-2973. |
[9] |
ZHENG Zhi-zhong1,2, YANG Zhong1*, XIU Lian-cun2, DONG Jin-xin2, CHEN Chun-xia2, GAO Yang2, YU Zheng-kui2. Design of a SWIR Offner Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2267-2272. |
[10] |
MAO Jing-hua1, 2, WANG Yong-mei1,2*, SHI En-tao1, ZHANG Zhong-mou1, JIANG Fang1. Study on the Slitfunction Test Method Based on Hyperspectral Imaging Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(04): 1286-1290. |
[11] |
PEI Lin-lin1, XIANGLI Bin1, 2, LIU Yang-yang2*, Lü Qun-bo2, SHAO Xiao-peng1 . The Snapshot Imaging Spectrometer with Image Replication Based on Wallaston Prism[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4105-4112. |
[12] |
LIU Yu-juan1, WANG Cheng-ming1, LIN Jun1*, CUI Ji-cheng2, ZHANG Tian-yu1*, ZHONG Zhi-cheng1* . Optimal Design of Light Folding Imaging Spectrometer Based on Dyson Concentric System [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2287-2290. |
[13] |
LIU Bing1, 2, LIU Ying1, ZHANG Xiao-long3, LI Can1, WANG Jian1, LI Chun1*, SUN Qiang1. Study on Coaxial Linear Dispersion Triplet Prisms of Wide Spectral Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1543-1548. |
[14] |
Lü Jin-guang1, LIANG Jing-qiu1, LIANG Zhong-zhu1*, TIAN Chao1, 2, QIN Yu-xin1. Analysis and Design of Interference Imaging System in Fourier Transform Imaging Spectrometer Based on Multi-Micro-Mirror[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1554-1559. |
[15] |
XIE Pei-yue1, 2, YANG Jian-feng1, XUE Bin1*, Lü Juan1, HE Ying-hong1, LI Ting1, MA Xiao-long1 . Research on an Equal Wavelength Spectrum Reconstruction Method of Interference Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 848-852. |
|
|
|
|