光谱学与光谱分析 |
|
|
|
|
|
New Type Distributed Optical Fiber Temperature Sensor (DTS) Based on Raman Scattering and Its’ Application |
WANG Jian-feng1, 2, LIU Hong-lin1, 2, ZHANG Shu-qin1, YU Xiang-dong1, 2, SUN Zhong-zhou2, JIN Shang-zhong1, 2, ZHANG Zai-xuan1, 2* |
1. Institute of Optoelectronics Technology, China Jiliang University, Hangzhou 310018, China 2. China Jiliang University-Beiyang Electrical Group Joint Optical Fiber Sensing Research Center, Hangzhou 310018, China |
|
|
Abstract Basic principles, development trends and applications status of distributed optical fiber Raman temperature sensor (DTS) are introduced. Performance parameters of DTS system include the sensing optical fiber length, temperature measurement uncertainty, spatial resolution and measurement time. These parameters have a certain correlation and it is difficult to improve them at the same time by single technology. So a variety of key techniques such as Raman amplification, pulse coding technique, Raman related dual-wavelength self-correction technique and embedding optical switching technique are researched to improve the performance of the DTS system. A 1 467 nm continuous laser is used as pump laser and the light source of DTS system (1 550 nm pulse laser) is amplified. When the length of sensing optical fiber is 50 km the Raman gain is about 17 dB. Raman gain can partially compensate the transmission loss of optical fiber, so that the sensing length can reach 50 km. In DTS system using pulse coding technique, pulse laser is coded by 211 bits loop encoder and correlation calculation is used to demodulate temperature. The encoded laser signal is related, whereas the noise is not relevant. So that signal-to-noise ratio (SNR) of DTS system can be improved significantly. The experiments are carried out in DTS system with single mode optical fiber and multimode optical fiber respectively. Temperature measurement uncertainty can all reach 1 ℃. In DTS system using Raman related dual-wavelength self-correction technique, the wavelength difference of the two light sources must be one Raman frequency shift in optical fiber. For example, wavelength of the main laser is 1 550 nm and wavelength of the second laser must be 1 450 nm. Spatial resolution of DTS system is improved to 2 m by using dual-wavelength self-correction technique. Optical switch is embedded in DTS system, so that the temperature measurement channel multiply extended and the total length of the sensing optical fiber effectively extended. Optical fiber sensor network is composed.
|
Received: 2013-02-14
Accepted: 2013-03-08
|
|
Corresponding Authors:
ZHANG Zai-xuan
E-mail: zhangzx@cjlu.edu.cn
|
|
[1] Rojers A. J. Electron. Lett., 1980, 16:489. [2] Dakin J P, Pratt D J, Bibby G W. Electron. Lett., 1985, (21):569. [3] Rogers A. J. Physics Reports, 1988, 169(2):99. [4] ZHOU Yun, YANG Jiang-li(周 芸,杨奖利). High Voltage Apparatus(高压电器), 2009, 45(4): 74. [5] JIANG Qi(蒋 奇). Applied Optics(应用光学), 2005, 26(3): 20. [6] SONG Hong-wei, GUO Hai-min, DAI Jia-cai,et al(宋红伟,郭海敏,戴家才,等). Well Logging Technology(测井技术), 2009, 33(4): 384. [7] ZHANG Yue, ZHANG Ji-long, LI Xiao, et al(张 悦,张记龙,李 晓,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2009, 29(5): 1300. [8] ZHANG Zai-xuan, JIN Shang-zhong, WANG Jian-feng, et al(张在宣,金尚忠,王剑锋,等). Chinese Journal of Lasers, 2010, 37(11): 2749. [9] ZHANG Zai-xuan, ZHANG Bu-xin, CHEN Yang, et al(张在宣,张步新,陈 阳,等). Acta Photonica Sinica(光子学报), 1996, 25(3): 273. [10] Lees G P, Leach A P, Hartog A H, et al. Electronics Letters, 1996,32(19): 1809. [11] ZHANG Zai-xuan, GONG Hua-ping(张在宣,龚华平). Chinese Patent(中国专利), 200710156868.0, 2009. [12] ZHANG Zai-xuan(张在宣). Chinese Patent(中国专利), 200910099463. 7, 2010. [13] Marcelo A Soto, Gabriele Bolognini, Fabrizio Di Pasquale, et al. Optics Letters, 2007, 35(2): 259. [14] YU Xiang-dong, ZHANG Zai-xuan, ZHANG Wen-sheng(余向东,张在宣,张文生). Chinese Patent(中国专利), 201010169596. X, 2011. [15] ZHANG Zai-xuan, JIN Shang-zhong, WANG Jian-feng, et al(张在宣,金尚忠,王剑锋,等). Chinese Patent(中国专利), 201010145912. X, 2012. [16] ZHANG Zai-xuan(张在宣). Chinese Patent(中国专利), 200910102201. 1, 2011. [17] WANG Jian-feng, HONG Yan, MA Jiang-dong, et al(王剑锋,宏 岩,马建东,等). Journal of Optoelectronics·Laser, 2010, 21(9): 1291. [18] WANG Jian-feng, ZHANG Zai-xuan, YU Xiang-dong, et al(王剑锋,张在宣,余向东,等). Chinese Patent(中国专利), 201010133585. 6, 2010.
|
[1] |
LAI Chun-hong*, ZHANG Zhi-jun, WEN Jing, ZENG Cheng, ZHANG Qi. Research Progress in Long-Range Detection of Surface-Enhanced Raman Scattering Signals[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(08): 2325-2332. |
[2] |
LI Jia-jia, XU Da-peng *, WANG Zi-xiong, ZHANG Tong. Research Progress on Enhancement Mechanism of Surface-Enhanced Raman Scattering of Nanomaterials[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1340-1350. |
[3] |
PAN Ke-yu1, 2, ZHU Ming-yao1, 2, WANG Yi-meng1, 2, XU Yang1, CHI Ming-bo1, 2*, WU Yi-hui1, 2*. Research on the Influence of Modulation Depth of Phase Sensitive
Detection on Stimulated Raman Signal Intensity and
Signal-to-Noise Ratio[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1068-1074. |
[4] |
SUN Zhi-ming1, LI Hui1, FENG Yi-bo1, GAO Yu-hang1, PEI Jia-huan1, CHANG Li1, LUO Yun-jing1, ZOU Ming-qiang2*, WANG Cong1*. Surface Charge Regulation of Single Sites Improves the Sensitivity of
Raman Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1075-1082. |
[5] |
OUYANG Ke-chen1, 2, XING Li2, WANG Zheng2, 3, FENG Xiao-juan2*, ZHANG Jin-tao2, REN Cheng1, YANG Xing-tuan1. Analysis and Suppression of Laser-Induced Error in Temperature
Measurement Based on Nitrogen-Vacancy Centers in Diamond[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1242-1247. |
[6] |
YIN Xiong-yi1, SHI Yuan-bo1*, WANG Sheng-jun2, JIAO Xian-he2, KONG Xian-ming2. Quantitative Analysis of Polycyclic Aromatic Hydrocarbons by Raman Spectroscopy Based on ML-PCA-BP Model[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 861-866. |
[7] |
SUN Nan, TAN Hong-lin*, ZHANG Zheng-dong, REN Xiang, ZHOU Yan, LIU Jian-qi, CAI Xiao-ming, CAI Jin-ming. Raman Spectroscopy Analysis and Formation Mechanism of Carbon
Nanotubes Doped Polyacrylonitrile/Copper Cyclized to Graphite
at Room Temperature[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(09): 2983-2988. |
[8] |
JIAO Ruo-nan, LIU Kun*, KONG Fan-yi, WANG Ting, HAN Xue, LI Yong-jiang, SUN Chang-sen. Research on Coherent Anti-Stokes Raman Spectroscopy Detection of
Microplastics in Seawater and Sand[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1022-1027. |
[9] |
WANG Zi-xiong, XU Da-peng*, ZHANG Yi-fan, LI Jia-jia. Research Progress of Surface-Enhanced Raman Scattering Detection Analyte Molecules[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 341-349. |
[10] |
WAN Xiao-ming1, 2, ZENG Wei-bin1, 2, LEI Mei1, 2, CHEN Tong-bin1, 2. Micro-Distribution of Elements and Speciation of Arsenic in the Sporangium of Pteris Vittata[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 470-477. |
[11] |
HUANG Hui1, 2, TIAN Yi2, ZHANG Meng-die1, 2, XU Tao-ran2, MU Da1*, CHEN Pei-pei2, 3*, CHU Wei-guo2, 3*. Design and Batchable Fabrication of High Performance 3D Nanostructure SERS Chips and Their Applications to Trace Mercury Ions Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(12): 3782-3790. |
[12] |
LI Xiang-zhao1, HOU Guo-hui1,2*, HUANG Zhi-fan1, XIAO Jun-jun2. Coherent Anti-Stokes Raman Scattering Imaging for Small Beads[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(11): 3648-3652. |
[13] |
FU Xing-hu, WANG Zhen-xing, MA Shuang-yu, ZHAO Fei, LU Xin, FU Guang-wei, JIN Wa, BI Wei-hong. Preparation and Properties of Micro-Cavity Silver Modified Fiber SERS Probe[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2800-2806. |
[14] |
GUI Bo1, 2, YANG Yu-dong1, ZHAO Qian1, 2, SHI Meng1, MAO Hai-yang1, 3*, WANG Wei-bing1, CHEN Da-peng1, 3. A SERS Substrate for On-Site Detection of Trace Pesticide Molecules Based on Parahydrophobic Nanostructures[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(08): 2499-2504. |
[15] |
XU Chao-wen1, 2, 3, GAO Jing4*, LI Ying1*, QIN Fei5, LIU Hong1, YI Li1, CUI Yue-ju1, SUN Feng-xia1, FANG Lei-ming6. High Pressure Raman Spectrum Study of Na2CO3[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(07): 2087-2091. |
|
|
|
|