光谱学与光谱分析 |
|
|
|
|
|
Spectral Calibration for the Large Aperture Infrared Radiometer |
YE Zhao1, 2, WAN Zhi1, LI Xian-sheng1, REN Jian-wei1*, LIU Hong-xing1, 2 |
1. Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033, China 2. Graduate University of Chinese Academy of Sciences,Beijing 100049,China |
|
|
Abstract The present paper introduced a spectral calibration method to calibrate a large aperture infrared radiation facility. We developed a radiometer which consisted of optical system, infrared detectors(cavity pyroelectric detector and HgCdTe detector 2~14 μm), fine mechanical modulator, lock in amplifier, signal processor, etc. At first, we analyzed the method on how to measure the spectral calibration of the large aperture infrared radiometer, and established the spectral calibration facility. Then, we tested the nonlinear response for the cavity pyroelectric detector and HgCdTe detector. Finally, we used the cavity pyroelectric detector to calibrate the relative spectral responsivity of HgCdTe detector at several wavelengths on the facility. Through the comparison of the two methods for measuring the relative spectral responsivity, the average of multiple measurements and comparative analysis of two methods were given. The uncertainty analysis of the whole system showed that the measurement uncertainty of the facility was better than 3.4%.
|
Received: 2011-10-03
Accepted: 2012-03-20
|
|
Corresponding Authors:
REN Jian-wei
E-mail: renjw@ciomp.ac.cn
|
|
[1] HU Xiu-qing, ZHANG Li-yang, ZHENG Zhao-jun, et al(胡秀清,张里阳,郑照军,等). Optics and Precision Engineering(光学精密工程), 2010, 18(9): 1972. [2] SUN Xue-jin, LIU Jian, MAO Jie-tai(孙学金, 刘 剑, 毛节泰). J. Infrared Millim. Waves(红外与毫米波学报), 2009, 28(1): 54. [3] REN Jian-wei, WAN Zhi, LI Xian-sheng, et al(任建伟, 万 志,李宪圣,等). Optics and Precision Engineering(光学精密工程), 2007, 15(8):1186. [4] Theocharous E, Engtrakul C, Dillon A C, et al. Applied Optics, 2008, 47(22): 3999. [5] James G A, Philip A, Gail B, et al. Transactions American Geophysical Union, 2007, 88(11): 136. [6] ZHENG Yu-quan(郑玉权). Optics and Precision Engineering(光学精密工程), 2010, 18(11): 2347. [7] Theocharous E. Metrologia, 2006, 43: 115. [8] Theocharous E, Ishii J, Fox N P. Applied Optics, 2004, 43(21): 4182. [9] Theocharous E, Ishii J, Fox N P. Infrared Physics And Technology, 2005, 46(4): 309. [10] REN Jian-wei, LIU Ze-xun, WAN Zhi, et al(任建伟, 刘则洵, 万 志,等). Optics and Precision Engineering(光学精密工程), 2010, 18(7): 1491.
|
[1] |
WANG Jian-wei1, 2, LI Wei-yan1, SUN Jian-ying1, LI Bing1, CHEN Xin-wen1, TAN Zheng1, ZHAO Na1, LIU Yang-yang1, 3, LÜ Qun-bo1, 3*. Fast Spectral Calibration Method of Spectral Imager[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(07): 2013-2017. |
[2] |
XIE Yi-hang, DAI Cai-hong*, WANG Yan-fei, WU Zhi-feng, LI Ling, HE Shu-fang. A New Method for Inflection Point Temperature Calculation of Large-Area High-Temperature Fixed-Point Blackbody Used in Spectral Irradiance Scale Realization[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(12): 3942-3948. |
[3] |
PEI Guo-chao1, 2, LI Yuan3, 4*, BAI Ting-zhu1, 2. Temporal Variation Model of Ultraviolet Hyperspectral Solar Reference Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(08): 2332-2338. |
[4] |
HUANG Shan1, 2, SI Fu-qi1*, ZHAO Min-jie1, ZHOU Hai-jin1, JIANG Yu1. Study on the Slit Function of Atmospheric Trace Gas Differential Optical Absorption Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(07): 2008-2012. |
[5] |
ZOU Yao-pu1, 2, ZHANG Lei1, 2, HAN Chang-pei2*, LI Li-bing2. Study of High Accuracy Spectral Calibration of Fourier Transform Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(04): 1268-1275. |
[6] |
XU Na, HU Xiu-qing*, CHEN Lin. Evaluation and Correction of Atmosphere Contamination on the Measurement of the Spectral Response of FY-2 Water Vapor Channels[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2325-2330. |
[7] |
SHI Hai-liang, LI Zhi-wei, LUO Hai-yan, XIONG Wei . Error Correction of Spectral Calibration for Hyper-Spectral Atmosphere CO2 Monitoring Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2296-2299. |
[8] |
LI Xin1, 2, ZHANG Li-ming1, 2*, CHEN Hong-yao1, 2, XU Wei-wei1, 2 . On-Orbit Multispectral Sensor Characterization Based on Spectral Tarps [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 811-816. |
[9] |
LIN Jun, SHAO Jun, SONG Chao-yu,LI Yun-wei, LEI Yu-fei . High Precision Spectral Calibration Method of Fourier Interferometric Spectrometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(12): 3534-3537. |
[10] |
ZHAO Min-jie, SI Fu-qi*, LU Yi-huai, WANG Yu, WANG Shi-mei, JIANG Yu, ZHOU Hai-jin, LIU Wen-qing . Spectral Calibration of Space-born Imaging Spectrometers Using Spectrum-Matching Technique[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(07): 2049-2053. |
[11] |
SUN Ci1, 2, Bayanheshig1*, CUI Ji-cheng1, PAN Ming-zhong1, LI Xiao-tian1, TANG Yu-guo1 . Full-Field and Automatic Methodology of Spectral Calibration for PGP Imaging Spectrometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(08): 2289-2292. |
[12] |
WANG Ming-zhi, YAN Lei, YANG Bin, GOU Zhi-yang . Central Wavelength Shift Analysis between Laboratory and Field Spectral Calibrations of Grating Based Imaging Spectrometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(08): 2280-2285. |
[13] |
GOU Zhi-yang1,2, YAN Lei1, 2*, CHEN Wei1, 2, ZHAO Hong-ying1, 2, YIN Zhong-yi1, 2, DUAN Yi-ni1, 2 . Spectral Calibratioo of Hyperspectral Imager Based on Spectral Absorption Target[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(02): 571-574. |
[14] |
ZHOU Hai-jin1, 2, LIU Wen-qing2*, SI Fu-qi2, ZHAO Min-jie2, JIANG Yu2, XUE Hui2 . Spectral Calibration for Space-Borne Differential Optical Absorption Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(11): 2881-2885. |
[15] |
LIU Li1,2,3, GU Xing-fa1,3*, YU Tao1,3, LI Xiao-ying1,3, CHEN Xing-feng1,3, GAO Hai-liang1,3, LI Jia-guo1,3 . Research on Calibration Methods of Ground-Based Thermal-Infrared Radiometer CE312[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(02): 343-348. |
|
|
|
|