光谱学与光谱分析 |
|
|
|
|
|
Determination of Micro-Elements in Couplers by Inductively Coupled Plasma Atomic Emission Spectrometry |
DU Bao-an1 ,WANG Xiang-yan2 |
1.The Institute of Chemistry and Environment Science,Hebei University,Baoding 071002,China 2.Chinese Lucky Film Corporation, Baoding 071054,China |
|
|
Abstract By ICP-AES, we established a method to quantitatively determine the micro-elements in couplers. We processed the unknown sample with wet digesting method. Nine micro-elements in the couplers can be quantitatively determined at the same time. Using the powerful chem.-station, we have discussed the method to eliminate physical interference and background correction. The results of the experiment showed that the method is accurate, quick, of high performance,and with all RSDs≤1.00%. The linear correlation coefficient of the tested elements is over 0.999 9.
|
Received: 2002-06-05
Accepted: 2002-10-20
|
|
Corresponding Authors:
DU Bao-an
|
|
Cite this article: |
DU Bao-an,WANG Xiang-yan. Determination of Micro-Elements in Couplers by Inductively Coupled Plasma Atomic Emission Spectrometry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24(03): 354-356.
|
|
|
|
URL: |
http://www.gpxygpfx.com/EN/Y2004/V24/I03/354 |
[1] 陈新坤. 电感耦合等离子体光谱法原理和应用. 天津:南开大学出版社,1987. 357. [2] WANG Xiang-yan, DU Bao-an(王香艳,杜保安). Physical Testing and Chemical Analysis(理化检验),待发表. [3] SHEN Lan-sun, BAI Mei(沈兰荪,白 梅). Chinese J. of Analytical Chemistry(分析化学),1990,18(10):920. [4] ZHANG Zhuo-yong, LIU Si-dong, JILIN Bai-yin et al(张卓勇,刘思东,吉林白音等)。Chinese J. of Analytical Chemistry(分析化学),1998,26(3):317. [5] DUAN Yi-xiang, ZHANG Han-qi, LU Hui et al(段忆翔,张寒琦,鲁 惠等). Chinese J. of Analytical Chemistry(分析化学),1992,20(4):384. [6] Marc L Salit, Gregory C Yurk, Abigail P Lindstrom et al. Analytical Chemistry, 2001, 73: 4821. [7] QIAN Hao-wen, LI Wen-chong, HUANG Ying-hui et al(钱浩雯,李文冲,黄颖辉等). Analytical Instrument(分析仪器),1990,4:7. [8] ZHOU Shi-ping, ZHU Guang-hui, YIN Jia-yuan et al(周世萍,朱光辉,尹家元等). Chinese J. of Analytical Chemistry(分析化学),2002,30(1):67. [9] GONG Jing, ZHANG Wen-li, QIU De-ren et al(龚 静,张文莉,邱德仁等). Chinese J. of Analytical Chemistry(分析化学),2000,28(8):972.
|
[1] |
ZHAI Yu-xin1, CHEN Jun1, LI Ti1*, LIU Ji-yan2, WANG Xie-yi1, CHENG Chao1, LIU Cheng-mei1 . Determination of Mineral Elements in Choerospondias Axillaris and Its Extractives by ICP-AES [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(04): 1052-1055. |
[2] |
ZHANG Yun-liang1,2, LIU Yan-cheng1, SHI Shao-ming1, CHEN Zhen-feng1*, LIANG Hong1 . Determination of Contents of Many Kinds of Metal Elements in Phellodendron by ICP-AES[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(10): 2848-2850. |
[3] |
QIN Jiao-lan, CHEN Zhen-feng, LIU Yan-cheng, LIANG Hong. Determination of Trace Metal Elements in Zanthoxylum Nitidum by ICP-AES[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(10): 2851-2854. |
[4] |
XU Wan-zhen, LI Chun-xiang, LIU Ai-qin, YAN Yong-sheng*. ICP-AES Determination of Cu2+,Pb2+ and Cd2+ with Adsorption Behavior of Potassium Hexatitanate Whisker[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(03): 801-804. |
[5] |
DU Bao-an1, YANG Yu-hua2, LI Zheng-ping1 . Determination of Trace Elements Hg and Rh in Gelatin by Inductively Coupled Plasma Emission Spectrometry ——Applying MSF Model to Improve the Precision and Detection Limit[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(01): 140-143. |
[6] |
DU Bao-an1, SHEN Shi-gang1, LI Zhi-ting1, XU Jian-zhong1, MA Li-qian2, SUN Han-wen1 . Quantitatively Determining Trace Elements Co and Bi in Gelatin by Inductively Coupled Plasma Atomic Emission Spectrometry Method ——Applying IEC Model to Correct the Spectral Interference of Fe to Co [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(01): 113-115. |
|
|
|
|