光谱学与光谱分析 |
|
|
|
|
|
Studies on the Spectrum and Frequency Repetition of Double-Mode He-Ne Laser with Frequency Stabilization |
ZHANG Hui, SHEN Nai-zheng |
Institute of Physics, Chinese Academy of Sciences, Beijing 100080, China |
|
|
Abstract Theoretical analysis of spectrum and frequency repetition of the double-model frequency stabilization He-Ne laser has been done, and the beat frequency experiment using 632 nm I2 frequency stabilization He-Ne laser has been carried out.The authors used the intercavity laser, and the double mode frequency stabilization to get the laser stabilized output through adjusting the two neighbor vertically polarized modes to the equal power reference point.Through the experiment, the authors analyzed the factors which affect the laser frequency repetition and stabilization, and measured the stabilized laser power and the frequency stabilization.The beat frequency experiment has shown that the frequency repetition can reach (1-2)×10-8 by frequency difference, and the laser stabilization can reach 10-10 by Allan variances.The experiments show that the stabilized laser can work well and can be used as frequency reference point.
|
Received: 2005-01-08
Accepted: 2005-03-26
|
|
Corresponding Authors:
ZHANG Hui
|
|
Cite this article: |
ZHANG Hui,SHEN Nai-zheng. Studies on the Spectrum and Frequency Repetition of Double-Mode He-Ne Laser with Frequency Stabilization [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(07): 1009-1012.
|
|
|
|
URL: |
https://www.gpxygpfx.com/EN/Y2005/V25/I07/1009 |
[1] Balhorn H, Kunzmann R, Lebowsky.Appl.Opt., 1972, 11: 742. [2] Bennett S J, Ward R E, Wilson D C.Appl.Opt., 1973, 12: 1406. [3] Sasaki A, Hayashi T.Jpn.J.Appl.Phys., 1982, 21: 1455.[4] Yoshino T.Jpn.J.Appl.Phys., 1980, 19: 2181. [5] Araki T, Nakajima Y, Suzuki N.Appl.Opt., 1989, 28: 1525. [6] Yoon T H, Ye J, Hall J L, et al.Appl.Phys.B, 2001, 72: 221. [7] Shuko Yokoyama, Tsutomu Araki, Norihito Suzuki.Appl.Opt., 1994, 33(3):358.
|
[1] |
LIU Hong-bo, SHI Xue-shun, ZHUANG Xin-gang, ZHANG Peng-ju, LIU Chang-ming, WANG Heng-fei. Simulation and Experimental Measurement of Cryogenic Radiometer Cavity With Different Structures[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 654-659. |
[2] |
WANG Qi, WANG Shi-chao, LIU Tai-yu, CHEN Zi-qiang. Research Progress of Multi-Component Gas Detection by Photoacoustic Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 1-8. |
[3] |
LIU Hong-bo1, SHI Xue-shun1,XU Wen-bin2, LIU Chang-ming1, LIU Hong-yuan1, WANG Heng-fei1. Long-Wave Infrared Absolute Spectral Responsivity Scale by Using an Absolute Cryogenic Radiometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3680-3685. |
[4] |
XU Jian-wen1, 2 , CHEN Guo-qing1, 2*, WU Ya-min1, 2, MA Chao-qun1, 2, GU Jiao1, 2. Establishment of the Spectral Equation of Two Phosphor-Coated White LEDs[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(03): 799-803. |
[5] |
ZHUANG Xin-gang1, 2, LIU Hong-bo1, 2, ZHANG Peng-ju1, 2, SHI Xue-shun1, 2, LIU Chang-ming1, 2, LIU Hong-yuan1, 2, WANG Heng-fei1, 2. Absorptance Analysis of Blackbody Cavity in Cryogenic Radiometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(07): 2018-2022. |
[6] |
ZHAO Zhe1, 2, 3, WANG Hui1, WANG Hui-quan1, 2, 3*, HE Xin-wei1, MIAO Jing-hong1, 2, WANG Jin-hai1, 2*. Influence of Spectral Characteristics on the Accuracy of Concentration Quantitatively Analysis by NIR[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(04): 1070-1074. |
[7] |
WANG Jin-hai1, LIU Dong-yuan1, 2, WANG Hui-quan1*, ZHANG Yan-jun2, SUN Qiu-ming2, MA Jun2. Application of Multi-Channel Differential Optical Density on the Fast Determination of the Intracranial Hematomas Degree[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3205-3209. |
[8] |
ZHANG Yan-jun1, SUN Qiu-ming1, WANG Hui-quan2, ZHAO Zhe2, SUN Jing-gong1, MA Jun1*, LIU Dong-yuan1, 2. VIP Analysis to Simplify the NIR Detection Study of the Dural Hematoma[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(06): 1691-1695. |
[9] |
MOU Fu-sheng1,2, LI Ang1, XIE Pin-hua1,3,4, WANG Yang5, ZHANG Jie1, XU Jin1, WU Feng-cheng1, CHEN Hao1. Study of Tropospheric NO2 VCD from August 2013 to July 2014 with Ground-Based MAX-DOAS in Hefei and Comparison with OMI Observation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(04): 1042-1047. |
[10] |
HE Ying1,2, ZHANG Yu-jun1, YOU Kun1, GAO Yan-wei1, CHEN Chen1, LIU Wen-qing1 . Study on Hydrogen Fluoride at High Temperature Detection Method with Temperature Correction Based on Laser Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(03): 964-970. |
[11] |
JIANG Yan-xiu1, 2, Bayanheshig1*, YANG Shuo1, 2, ZHAO Xu-long1, 2, WU Na1, LI Wen-hao1 . Study on the Effects and Compensation Effect of Recording Parameters Error on Imaging Performance of Holographic Grating in On-Line Spectral Diagnose [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 857-863. |
[12] |
LU Xu-tao1, LI Jing2, Lü Hai-feng3 . Portable High-Precision System for CH4 Concentration Detection in Mines based on the Laser Mode-Hopping [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(03): 846-849. |
[13] |
LI Le, HU Yi-hua*, GU You-lin, CHEN Wei, ZHAO Yi-zheng, CHEN Shan-jing . Measurement and Analysis on Complex Refraction Indices of Pear Pollen in Infrared Band [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(01): 89-92. |
[14] |
LI Jing1, LU Xu-tao2, YANG Ze-hui3 . Remote System of Natural Gas Leakage Based on Multi-Wavelength Characteristics Spectrum Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(05): 1249-1252. |
[15] |
LI Da-chao, YANG Di, YANG Jia, ZHANG Jing-xin, WU Peng, YU Hai-xia, XU Ke-xin . Research on Glucose Measuring Technique by Surface Plasmon Resonance Based on Thiol Coupling [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(03): 605-608. |
|
|
|
|