光谱学与光谱分析 |
|
|
|
|
|
Measurement Technology for Relative Spectral Responsivity of the Ultraviolet ICCD |
ZHAO Yu-huan1, 2, YAN Feng1, LOU Hong-wei1, SUI Yong-xin1, YANG Huai-jiang1, CAO Jian-lin1 |
1. State Key Lab of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China 2. Graduate University of Chinese Academy of Sciences, Beijing 100039, China |
|
|
Abstract The spectral responsivity is one of the important parameters of detector. With the development of ultraviolet detect technique, accurate measure for the spectral responsivity of ultraviolet detector becomes more and more important. A measure principle which is based on the direct comparison measuring method for relative spectral response measurement of the ultraviolet ICCD is introduced. Based on the scientific-grade spectrometer with ultraviolet responsivity, a measurement facility was built. The relative spectral responsivity curve of the ultraviolet ICCD was obtained. The curve indicates that the spectral response of UV-ICCD is from 220 to 300 nm and the peak response is near 270 nm, which indicates that the UV-ICCD is solar blind. The analysis of the uncertainty shows that the most largest uncertainty of measurement for relative spectral responsivity of the UV-ICCD is 7.79% and meets the requirement.
|
Received: 2007-12-20
Accepted: 2008-03-09
|
|
Corresponding Authors:
ZHAO Yu-huan
E-mail: yhzh0505@163.com
|
|
[1] LOU Ying, BAI Ting-zhu, GAO Zhi-yun, et al(娄 颖,白廷柱,高稚允,等). Optical Technology(光学技术), 2005, 31(3): 473. [2] Filip Neele, Ric Schleijpen. SPIE, 2003, 5075: 270. [3] Malka Lindner, Shimon Elstein, Pinhas Lindner. SPIE, 1998, 3434: 22. [4] YAN Feng, YU Zi-jiang, YU Xiao, et al(闫 丰,于子江,于 晓,等). Optics and Precision Engineering(光学精密工程), 2006, 14(4): 709. [5] YAO Ming-hui, LI Zi-tian, LIU Jun(姚明晖,李自田,刘 军). Science Technology and Engineering(科学技术与工程), 2007, 7(7): 1320. [6] ZHANG Jian-min, LIN Yan-dong, SHAO Jing, et al(张建民,林延东,邵 晶,等). Acta Metrologica Sinica(计量学报), 1998, 19(3): 194. [7] JIANG Yue-juan(蒋月娟). Optical Instruments(光学仪器), 2000, 22(2): 3. [8] LIU Jin-yuan, XUE Feng-yi(刘金元,薛凤仪). Metrological Technique(计量技术), 2002, (3): 19. [9] LIU Ying, LI Fu-tian(刘 颖,李福田). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2001, 21(4): 427. [10] TANG Yu-guo, LI Fu-tian (唐玉国,李福田). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 1996, 16(4): 7. [11] WAN Feng, SUN Hong-wei, FAN Shi-fu(万 峰,孙宏伟,范世福). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2006, 26(4): 779.
|
[1] |
CHENG Hong1, YAN Ding-ce1*, WU Li-qing2, XU Jun3. Spectral Magnitude Uncertainty in Measurement of Protein Circular
Dichroism Spectra—An Empirical Study on Cytochrome C[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3105-3110. |
[2] |
LIU Hong-yuan1, WU Bin1, 2, JIANG Tao3, YANG Yan-zhao1, WANG Hong-chao1, LI Jing-song1. Study on the Measurement of Absolute Spectral Responsivity of Terahertz Detector[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1017-1022. |
[3] |
LONG Jiang-xiong1, 2, ZHANG Yu-jun1*, SHAO Li1*, YE Qing1, 2, HE Ying3, YOU Kun3, SUN Xiao-quan1, 2. Traceable Measurement of Optical Path Length of Gas Cell Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(11): 3461-3466. |
[4] |
HOU Ya-ru, LU Ji-long*, FAN Yu-chao, Abudusalamu·KADIER, TANG Xiao-dan, WEI Qiao-qiao, GUO Jin-ke, ZHAO Wei. Uncertainty Evaluation and Method Improvement of Determination of Copper, Lead, and Zinc in Rocks by Atomic Absorption Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(07): 2101-2106. |
[5] |
DAI Cai-hong, WU Zhi-feng, WANG Yan-fei, LI Ling. Realization of National Primary Standard Apparatus of Spectral Irradiance from 200 to 400 nm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(08): 2640-2644. |
[6] |
DONG Hai-long, WANG Jia-chun*, ZHAO Da-peng, CHEN Zong-sheng, LIU Rui-huang, SHI Jia-ming. Analysis of Measurement Uncertainty in THz-TDS Carried by Delay-Line Position Deviation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(11): 3379-3384. |
[7] |
HUANG Min, HE Rui-li, SHI Chun-jie, SHI Bing-jie, LIU Hao-xue. Test the Performances of Different Color Matching Functions with the Method of Comparison[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2241-2249. |
[8] |
GAO Rui-feng1, 2, GAO Meng-chao3, LING Rui3, ZHANG Ning1* . Improving Analytical Methods by Uncertainty Evaluation with the Case of Determination of Aluminum in Starch Products by ICP-MS [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(04): 1211-1216. |
[9] |
XUE Zhong1, XU Bing1*, LIU Qian1, SHI Xin-yuan1, 2, LI Jian-yu1, WU Zhi-sheng1, QIAO Yan-jiang1, 2* . Application of Uncertainty Assessment in NIR Quantitative Analysis of Traditional Chinese Medicine [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(10): 2657-2661. |
[10] |
WANG Yi-ya, ZHAN Xiu-chun . The Uncertainty Evaluation of Analytical Results of 27 Elements in Geological Samples by X-Ray Fluorescence Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(04): 1118-1123. |
[11] |
WANG Hai-feng, LU Hai, LI Jia, SUN Guo-hua, WANG Jun, DAI Xin-hua . Determination of the Content of Sulfur of Coal by the Infrared Absorption Method with High Acccuracy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(02): 370-375. |
[12] |
XING Li, WANG Mei, ZHAO Feng-min*, CAO You-fu, ZHANG Xiao-yan, CAI Zhi-yong . Determination and Uncertainty Evaluation of Microelements in Flaxseed by Using ICP-MS Under Two Modes [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(01): 226-230. |
[13] |
YAN Feng, ZHOU Yue*, ZHANG Ming-chao, CHEN Xue . Test Equipment for Relative Spectral Response of CCD [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(10): 2865-2868. |
[14] |
SUN Kun1, 2, SUN Xiao-gang3, YU Xiao-yang1, SUN Xiao-ming1. Development of Multi-Spectral Thermometer for Explosion Flame True Temperature Measurement——Field Experiments and Measurement Accuracy Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(06): 1719-1722. |
[15] |
LIN Ling1, XIONG Bo1, ZHAO Shuang-qi2, LIU Gui-li2, WANG Xiao-fei2, LI Gang1 . A Spectrum Extraction Method Based on Uncertainty in Noninvasive Blood Components Examinaton [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(02): 459-463. |
|
|
|
|