Accurate Determination of Boron Content and Isotope in Salt
PENG Zhang-kuang1, 3, LI Hai-jun2, CHAI Xiao-li2, XIAO Ying-kai1, ZHANG Yan-ling1, YANG Jian1, 3, MA Yun-qi1, 2*
1. Laboratory of Salt Lake Geology and Environment,Key Laboratory of Qinghai Institute of Salt Lakes, Northwest Institute of Eco-Environment and Resources, Chinese Academy of Sciences, Xining 810008, China
2. Salt Lake Chemical Analyzing and Testing Center,Key Laboratory of Qinghai Institute of Salt Lakes, Northwest Institute of Eco-Environment and Resources, Chinese Academy of Sciences, Xining 810008, China
3. University of Chinese Academy of Sciences, Beijing 100049, China
Abstract:The accurate content of boron directly restricts the boron isotope determination by using Positive Thermal Ionization Mass spectrometry based on Cs2BO+2 ion. At present, there is a big problem in determination of high salt and low boron samples with Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES), mainly in two aspects: high salt matrix interference and instrument detection limit,and simple dilution can not solve these difficulties very well. At present, the above two problems will be encountered when determining the boron content in the salt samples by ICP-OES, therefore, it is necessary to enrich boron and remove the matrix ions. In this paper, Amberlite IRA 743 boron-specific resin is applied to purify the boron element, and the high-salt matrix can be removed, but there are some sodium ions adsorbing at the same time. Using 3 mol·L-1 NH3·H2O can remove most of the adsorbed sodium ions and have no effect on the adsorbed boron. Then eluting boron from the resin with10 mL 0.1 mol·L-1 HCl at 75 ℃. 208.900 nm was chosen as the detection wavelength for boron, and the recoveries were in the range of 106.00%~108.40%; the detection identification and quantification limits are 0.006 and 0.02 mol·L-1, respectively. Through the 12 times repeated experiments under different salinities, the relative standard deviations range from 1.94% to 3.37%, which less than 5%, so we think the method is feasible, and there is no accidental error. Combining with this method and Positive Thermal Ionization Mass spectrometry based on Cs2BO+2ion, the deternination of the boron content and isotopic composition of eight salt samples are achieved.
Key words:Amberlite IRA 743 resin;ICP-OES;Boron content;P-TIMS;Boron isotope
彭章旷,李海军,柴小丽,肖应凯,张艳灵,杨 剑,马云麒. 石盐中硼含量及其同位素的准确测定[J]. 光谱学与光谱分析, 2017, 37(08): 2564-2568.
PENG Zhang-kuang, LI Hai-jun, CHAI Xiao-li, XIAO Ying-kai, ZHANG Yan-ling, YANG Jian, MA Yun-qi. Accurate Determination of Boron Content and Isotope in Salt. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2564-2568.
[1] MA Ru-ying, HAN Feng-qing, MA Hai-zhou, et al(马茹莹,韩凤清,马海州,等). Acta Geoscientica Sinica(地球学报),2015,(1): 60.
[2] SONG Wei-jiao, DAI Shi-feng, ZHAO Lei, et al(宋伟娇, 代世峰, 赵 蕾, 等). Rock and Mineral Analysis(岩矿测试), 2014, 33(3): 327.
[3] ZHAO Ling, FENG Yong-ming, LI Sheng-sheng, et al(赵 玲, 冯永明, 李胜生, 等). Rock and Mineral Analysis(岩矿测试), 2010, 29(4): 355.
[4] SHAO Xin, LI Xiao-dan, ZHU Yuan-yuan, et al(邵 鑫, 李小丹, 朱园园, 等). Chinese Journal of Spectroscopy Laboratory(光谱实验室), 2012, 29(5): 3256.
[5] YAN Xiong, JIANG Shao-yong, WEI Hai-zhen, et al(晏 雄, 蒋少涌, 魏海珍, 等). Chin. J. Anal. Chem.(分析化学), 2012, 40(11): 1654.
[6] CUI Li-li, ZHANG Li-xin(崔黎黎, 张立新). Metallurgical Analysis(冶金分析), 2010, 30(2): 58.
[7] ZHAO Tao, MIAO Hong(赵 涛, 缪 红). Metallurgical Analysis(冶金分析), 2016, 36(4): 34.
[8] SUN Dong-ya, HE Li-wen(孙东亚, 何丽雯). Metallurgical Analysis(冶金分析), 2014, 34(10): 42.
[9] XIAO Ying-kai(肖应凯). Thormionic Emission Characteristics of Graphite and Its Applications(石墨的热离子发射特性). Beijing: Science Press(北京: 科学出版社), 2003.
[10] MA Yun-qi, XIAO Ying-kai, ZHUGE Qin, et al(马云麒, 肖应凯, 诸葛芹, 等). Bulletin of Mineralogy, Petrology and Geochemistry(矿物岩石地球化学通报), 2010, 29(3): 250.
[11] HE Mao-yong, MA Yun-qi, JIN Zhang-dong, et al(贺茂勇, 马云麒, 金章东, 等). Journal of Chinese Mass Spectrometry Society(质谱学报), 2013, 34(2): 75.
[12] ZHANG Yan-ling, XIAO Ying-kai, MA Yun-qi, et al(张艳灵, 肖应凯, 马云麒, 等). Chin. J. Anal. Chem.(分析化学), 2016, 44(5): 809.
[13] Sandroni V, Smith C M M, Donovan A. Talanta, 2003, 60(4): 715.