Abstract:The measurement of tissue optical parameters is the focusing research content of Biomedical Photonics. The optical properties of human tissue are closely related to the physiological and pathological state. In recent years, the tissue imaging diagnosis and non-invasive detection of componentsbecome the hot research topics, applying the tissue optical properties especially the absorption and scattering properties. These provide the basis for the study of optical imaging and the spectrum detection of body composition etc. The Double-Integrating-Spheres (DIS) method can measure the absorption coefficient, scattering coefficient and so on in vitro tissuesimultaneously. It has the advantages of accurate, rapid, large applicable scope. The method applya standard method for measuring the optical parameters. This paper build the wide spectrum measurement system of optical parameters based on DIS and super continuum lasers. Then we analyze the transfer function, error sources and the best measuring conditions of the system. Finally we establish the correction forward model based on BP-MCML and the inverse algorithm of the optical parameters based on L-M algorithm. The optical parameters of intralipid solution in the wavelength range of 1 100~1 400 nm are measured. The experiment results show that the improved inverse algorithm is accurate. The multiple measurements standard deviation is within 3%. Compared the results of scattering coefficient and absorption coefficient at different wavelengths to the results of other research groups, the deviation is less than 3.4%.
韩 蕾1,李晨曦1,2*,孙承涛1,蒋景英1,赵会娟1,2,徐可欣1,2 . 基于双积分球的宽光谱组织光学参数测量系统与方法研究 [J]. 光谱学与光谱分析, 2016, 36(02): 561-566.
HAN Lei1, LI Chen-xi1, 2*, SUN Cheng-tao1, JIANG Jing-ying1, ZHAO Hui-juan1,2, XU Ke-xin1,2 . The Research on Measurement System and Method of Tissue Optical Parameters with Wide Spectra Based on Double-Integrating-Spheres. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(02): 561-566.
[1] Moritz Friebel, Jürgen Helfmann, et al. Journal of Biomedical Optics, 2009, 14(3): 034001. [2] Wang Yanqiu, Lin Ling, et al. Optical Technique, 2001, 27(4): 355. [3] Tamara L Troy, Suresh N Thennadil. Journal of Biomedical Optics, 2001, 6(2): 167. [4] Xu Kexin, et al. Biomedical Photonics. Beijing: Science Press, 2007. [5] Wang Qiuyin. Investigations on the Improvement of Double-Integrating-Spheres System for Measuring Tissue Optical Properties. Tianjin: College of Precision Instrument and Electronic Engineering, Tianjin University, 2010. [6] de Vries G, Beek J F, et al. IEEE Journal of Selected Topics in Quantum Electronics, 1999, 5(4): 944. [7] Zhu Dan, Lu Wei, et al. Journal of Biomedical Optics, 2007, 12(6): 064004. [8] Erik Alerstam, et al. Journal of Biomedical Optics, 2008, 13(6): 060504. [9] Guan Tangbing. A Study on Reconstruction of Tissue Optical Properties Based on Monte Carlo Propagation Model. Tianjin: College of Precision Instrument and Electronic Engineering, Tianjin University, 2007. [10] Wang Lihong, et al. Computer Methods and Programs in Biomedicine, 1995, 47: 131. [11] Li Chenxi, Zhao Huijuan, et al. Chinese Optical Letters, 2010, 8(2): 173. [12] MIAO Jing, CAO Yu-zhen, YANG Ren-jie, et al(苗 静,曹玉珍,杨仁杰,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2013, 33(11): 3032. [13] Yang Liu. Numerical methods for system of singular nonlinear equations and nonlinear least square problems. Xiangtan: Department of Mathematics, Xiangtan University, 2003. [14] Chen C, et al. Optics Express, 2006, 14(16): 7420.