Quantitatively Determining Trace Elements Co and Bi in Gelatin by Inductively Coupled Plasma Atomic Emission Spectrometry Method ——Applying IEC Model to Correct the Spectral Interference of Fe to Co
DU Bao-an1, SHEN Shi-gang1, LI Zhi-ting1, XU Jian-zhong1, MA Li-qian2, SUN Han-wen1
1. Analytic Science and Technology Laboratory of Hebei Province, Medicine Department of Chemistry and Environment Science Institute,Hebei University, Baoding 071002,China 2. Chinese Lucky Film Corporation, Baoding 071002,China
Abstract:By ICP-AES, the authors established the method to quantitatively determine the trace elements Co and Bi in gelatin. The authors processed the unknown sample with wet digesting method. Trace elements in gelatin could be quantitatively determined at the same time. To correct the spectral interference of Fe to Co at specific wavelength,the Interelement Correction(IEC) model was established. The results of the experiment showed that the IEC model could effectively erase the spectral interference of Fe to Co. The result of the spectral correction was greatly superior to the result where the spectral interference weren′t corrected by the IEC model. The method was accurate, quick with high performance and wide linear range. The linear correlation coefficient of the tested elements was over 0.999 90. The relative standard deviation (RSD%) was less than 2.00%. The recovery rates were in the range of 98%-107%.
Key words:Inductively coupled plasma atomic emission spctrometry(ICP-AES);IEC model;Gelatin;Trace elements Co and Bi
杜保安1,申世刚1,李志庭1,徐建中1,马礼谦2,孙汉文1 . 电感耦合等离子体原子发射光谱法定量测试明胶中的微量元素Co和Bi——应用IEC模型校正Fe对Co的光谱干扰 [J]. 光谱学与光谱分析, 2005, 25(01): 113-115.
DU Bao-an1, SHEN Shi-gang1, LI Zhi-ting1, XU Jian-zhong1, MA Li-qian2, SUN Han-wen1 . Quantitatively Determining Trace Elements Co and Bi in Gelatin by Inductively Coupled Plasma Atomic Emission Spectrometry Method ——Applying IEC Model to Correct the Spectral Interference of Fe to Co . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(01): 113-115.
[1] HE Bang-ping(何邦平主编). Progresses of Trace Elements Studies(微量元素研究进展·第3辑). Beijing: Chinese Forestry Press(北京: 中国林业出版社),1999. 52. [2] KONG Xiang-rui(孔祥瑞主编). Progresses of Medical Trace Elements of China(中华医学微量元素研究进展). Urumqi: Xingjiang Science Technology and Hygiene Press(乌鲁木齐:新疆科技卫生出版社),1996. (11):82. [3] CHEN Qing,LU Guo-cheng(陈 清,卢国埕). Trace Elements and Health(微量元素与健康). Beijing: Peking University Press(北京:北京大学出版社),1989. 102. [4] WU Xue-han,CUI Guang-chen,PENG Yun(吴学汉,崔光晨,彭 云). Chinese Journal of Analytical Chemistry(分析化学),1991,19(11):1352. [5] Perkin Elmer<sup>TM</sup>. WinLab32<sup>TM</sup> Instrument Control Software, Software Guide. 2000, 308. [6] SHEN Lan-sun,BAI Mei(沈兰荪,白 梅). Chinese Journal of Analytical Chemistry(分析化学),1990,18(10):920. [7] ZHANG Zhuo-yong,LIU Si-dong,JILIN Bai-yin et al(张卓勇,刘思东,吉林白音等). Chinese Journal of Analytical Chemistry(分析化学),1998,26(3):317. [8] DUAN Yi-xiang,ZHANG Han-qi,LU Hui et al(段忆翔,张寒琦,鲁 惠等). Chinese Journal of Analytical Chemistry(分析化学),1992,20(4):384. [9] Salit M L,Yurk G C, Lindstrom A P et al. Analytical Chemistry, 2001, 73: 4821. [10] JIANG Zu-cheng,TIAN Li-qing,CHEN Xin-kun et al(江祖成,田笠卿,陈新坤等). Modern Atomic Emission Spectral Analysis(现代原子发射光谱分析). Beijing:Science Press(北京:科学出版社),1999. 173,195. [11] HUANG Wen-sheng,WANG Hong,ZHANG Jun-feng et al(黄文胜,王 红,张军锋等). Chinese Journal of Analytical Chemistry(分析化学),2002,30(4):470. [12] QIAN Hao-wen,LI Wen-chong,HUANG Ying-hui et al(钱浩雯,李文冲,黄颖辉等). Analytical Instrument(分析仪器),1990,(4):7. [13] ZHOU Shi-ping,ZHU Guang-hui,YIN Jia-yuan et al(周世萍,朱光辉,尹家元等). Chinese Journal of Analytical Chemistry(分析化学),2002,30(1):67. [14] GONG Jing,ZHANG Wen-li,QIU De-ren et al(龚 静,张文莉,邱德仁等). Chinese Journal of Analytical Chemistry(分析化学),2000,28(8):972. [15] ZHONG Zhi-guang,BIAN Qun-zhou,ZHENG Jian-guo, CHEN Pei-ling, LIU Chong-hua, WEI Xian-ying(钟志光,卞群洲,郑建国,陈佩玲,刘崇华,魏暹英). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2002,22(1):83.