光谱学与光谱分析 |
|
|
|
|
|
Optimization Study of Non-Contact Color Measurement Parameters |
WAN Xiao-xia1, FU Ma1, HUANG Xin-guo2, XIE Wei1, LI Jun-feng1, LIU Qiang1 |
1. School of Printing and Packaging, Wuhan University, Wuhan 430079, China 2. College of Packaging and Material,Hunan University of Technology,Zhuzhou 412008,China |
|
|
Abstract Spectral data or chrominance data acquired with color measurement device is able to objectively characterize the true color information of the object. As to the measuring target that without direct contact with the measuring instrument, it needs to adopt the non-contact color measurement method to obtain the color information.The spectral irradiance theoretical analysis shows that the changes of the color illumination distance, measuring distance and exposure time have greater impact on the measurement results. However, there is no in-depth study on the influence of the changes of measuring parameters for the measured results. In order to get the most accurate measurement results in the process of non-contact color measurement, parameter optimization study based on orthogonal experiment was proposed. Experiment with different combinations of parameters was conducted to obtain the color information of ColorChecker via PR705 spectroradiometer with range analysis and variance analysis method.Experimental results show that the minimum color difference of measured value and the standard value is 0.878 8ΔE, and the maximum color difference is 1.543 1ΔE. Data results show that the proposed method can effectively select the best combination of parameters, and to analyze the impact of various parameters on the result.
|
Received: 2015-01-07
Accepted: 2015-04-25
|
|
Corresponding Authors:
WAN Xiao-xia
E-mail: wan@whu.edu.cn
|
|
[1] Wyble D R, Rich D C. Color Research and Application, 2007, 32(3): 166. [2] Chorro Elísabet, Perales Esther, Navarro Victor, et al. Reproducibility Comparison Between Two Multi-Gonio-Spectrophotometers, in AIC 2009, Proceedings, 2009. [3] Berns R S, Zhao Y H, Taplin L A, et al. The Use of Spectral Imaging as an Analytical Tool for Art Conservation, Presented at the American Institute of Conservation Annual Meeting, 2009. [4] Cozzolino D, Cynkar W U, Dambergs R G, et al. Communications in Soil Science and Plant Analysis, 2013, 44: 1610. [5] GUO Yan, JI Wen-jun, WU Hong-hai, et al(郭 燕,纪文君,吴宏海,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2013, 33(4):1135. [6] Wee A G, Beatty M W, Gozalo-Diaz D J, et al. J. Prosthetic Dent, 2013, 22: 83. [7] Hasegawa Akira, Motonomi Akio, Ikeda Ikuo. Color Research and Application, 2000, 25(1):43. [8] Akira Hasegawa,Ikeda I, Kawaguchi S. Journal of Prosthetic Dentistry, 2000, 83(4): 418. [9] Wee Alvin G, Lindsey Delwin T, Kuo Shanglun. Dental Materials, 2006, 22(6); 553. [10] Gozalo-Diaz David J, Lindsey D T, Johnston W M, et al. J. Prosthetic Dent, 2007, 97(1): 45. [11] JIN Wei-qi, HU Wei-jie(金伟其,胡威捷). The Fundamental and Measurement of Radiometry, Photometry and Colorimetry(辐射度 光度与色度及其测量). Beijing: Beijing Institute of Technology Press(北京:北京理工大学出版社),2009. 7. |
[1] |
CHENG Gang1, CAO Ya-nan1, TIAN Xing1, CAO Yuan2, LIU Kun2. Simulation of Airflow Performance and Parameter Optimization of
Photoacoustic Cell Based on Orthogonal Test[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(12): 3899-3905. |
[2] |
LIU Pan1, 2, 3, DU Mi-fang1*, LI Bin1, LI Jing-bin1, ZENG Lei1, LIU Guo-yuan1, ZHANG Xin-yao1, 4, ZHA Xiao-qin1, 4. Determination of Trace Tellurium Content in Aluminium Alloy by
Inductively Coupled Plasma-Atomic Emission Spectrometry Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(10): 3125-3131. |
[3] |
LI Ling, DAI Cai-hong, WU Zhi-feng, WANG Yan-fei. Laboratory Calibration and Temperature Research of Spectral Radiometric Instruments[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(06): 1965-1969. |
[4] |
YE Qi1,2, WANG Yue-ming1*, ZHOU Shi-yao1,2, CHENG Xiao-yu1,2, JIA Jian-xin1,2. Color Discrimination Based on Hyperspectral Imaging Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3310-3314. |
[5] |
ZHANG Yu1, WANG Dong-fang1, CAO Bing1, LUO Shi-heng2, LIU Ya-qiong1, HUANG Ning-hua1, YAN Lai-lai1, WANG Jing-yu1*. Orthogonal Experiment for Optimization of the Sample Pretreatment Conditions for the Serum Cholesterol and Markers Determination by GC-MS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1488-1493. |
[6] |
ZHAO Jing1, 2, LI Hai-jun1, SUN Bai1*, SONG Peng-sheng1 . Determination of Lithium and Strontium at High Concentration by ICP-AES[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(06): 1666-1670. |
[7] |
SHI Yan1,ZHENG Wei-wan1,XIAO Wei-wei2,SONG Jian-jun1,LI Xiao-dan1 . Determination of Nutrition Elements in Yak Milk Powder by Atomic Absorption Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(12): 2588-2590. |
[8] |
HU Hao-bin1*, CAO Hong2, LIU Jian-xin3, ZHENG Xu-dong1. Determination of Inorganic Elements in Elsholtzia bodinieri Vaniot from Gansu by Microwave Digestion ICP-AES[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(11): 2130-2133. |
[9] |
WANG Ying, XIN Shi-gang. Application of Orthogonal Test in Determination of Trace Elements in Wild Vegetables by ICP-AES [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24(10): 1253-1256. |
|
|
|
|