光谱学与光谱分析 |
|
|
|
|
|
Impact and Improvement of the Mechanical Shutter on Large-Array Filter-Type Multispectral Imaging System |
ZHAO Bao-wei1, 2, XIANGLI Bin1, 2, Lü Qun-bo2, ZHANG Gui-feng2, LIU Jiu2 |
1. Xidian University, Xi’an 710071, China 2. Academy of Opto-Electronics, Chinese Academy of Sciences, Beijing 100094, China |
|
|
Abstract The present paper analyzes the impact of mechanical shutter on the spectral image acquisition and processing of large-array filter-type multispectral imaging system. The final image quality relies highly on the mechanical shutter due to the fluctuation at exposure time. The conventional mechanical shutter’s structure and driving method was analyzed to find out the key fact for its poor stability. An improved method of mechanical transmission and circuit driving was proposed. Laboratory experiments showed that with the improved design strategy, the maximum rate of change between adjacent exposures was reduced from 15.05% to 0.96%, which is a great improvement of the exposure time stability. Field test was also carried out and the results show that the combined color images are closer to the realistic targets and no abrupt color change iwas found. It’s of great significance for practical application in multispectral image process, interpretation and target identification.
|
Received: 2012-12-13
Accepted: 2013-03-04
|
|
Corresponding Authors:
ZHAO Bao-wei
E-mail: zbw8200980@163.com
|
|
[1] Cohen J. BE,1993, 35(7): 26. [2] WANG Hai-yong, SHEN Gong-xun(王海涌,申功勋). Opto-Electronic Engineering(光电工程),2006, 33(8): 131. [3] DU Yun-fei, LIU Bo, HU Bing-liang, et al(杜云飞, 刘 波, 胡炳樑, 等). Acta Photonica Sinica(光子学报),2009, 38(4): 1027. [4] CHE Nian-zeng,YAN Da-yuan(车念曾,闫达远). Radiometry and Photometry(辐射度学与光度学). Beijing: Beijing Institute of Technology Press(北京:北京理工大学出版社), 1990. 38. [5] LOU Jie, LI Qing-min, ZHAO Tong, et al(娄 杰,李庆民,赵 彤,等). Low Voltage Apparatus(低压电器),2005, 11: 11. [6] BAI Zhi-hong, ZHOU Yu-hu(白志红,周玉虎). Journal of Electric Power(电力学报),2004, 19(3): 201. [7] XU Yan, ZHOU Xiao-feng(许 艳,周效锋). Journal of Qujing Teachers College(曲靖师范学院学报),2005, 24(3): 26. [8] WANG Han, XU Hai-song, CUI Gui-hua, et al(王 寒,徐海松,Guihua Cui, 等). Acta Optica Sinica(光学学报),2008, 28(8): 1631. |
[1] |
SUN Hua-sheng1, ZHANG Yuan2*, SHI Yun-fei1, ZHAO Min1. A New Method for Direct Measurement of Land Surface Reflectance With UAV-Based Multispectral Cameras[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(05): 1581-1587. |
[2] |
WANG Jian-wei, PEI Lin-lin, TAN Zheng, HUANG Min*, Lü Qun-bo, LIU Yang-yang, LI Wei-yan. Study on the Relative Radiance Calibration Method of Large Array Filter-Type Multispectral Imaging System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2615-2618. |
[3] |
LI Xin1, 2, ZHANG Li-ming1, 2*, CHEN Hong-yao1, 2, XU Wei-wei1, 2 . On-Orbit Multispectral Sensor Characterization Based on Spectral Tarps [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 811-816. |
[4] |
ZHANG Tong-rui, ZHAO Geng-xing*, GAO Ming-xiu, WANG Zhuo-ran, JIA Ji-chao, LI Ping, AN De-yu . Soil Salinity Estimation Based on Near-Ground Multispectral Imagery in Typical Area of the Yellow River Delta [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(01): 248-253. |
[5] |
HAN Jie1, 2, 3, XIE Yong1, 3*, GU Xing-fa1, 3, YU Tao1, 3, LIU Qi-yue1, 3, GAO Rong-jun1, 2, 3 . In-Flight Radiometric Calibration for ZY-3 Satellite Multispectral Sensor by Modified Reflectance-Based Method [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(03): 856-861. |
[6] |
BAI Yu1, 2, 3, XING Ting-wen1, JIANG Ya-dong2, FENG Cheng4 . Design and Study of Middle Infrared Spectrum System with Variational Field of View [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(08): 2293-2297. |
|
|
|
|