Ring-Shaped Wearable Optical Sensors Enhancing the Stability of
Human-Sensor Contact State |
GE Qing, LIU Jin, HAN Tong-shuai*, LIU Wen-bo, LU Yue |
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
|
|
|
Abstract In non-invasive wearable spectral sensors, ensuring the stability of the contact state between the human body and the sensor is essential for optimal sensor performance. Human movements and changes in body posture can cause variations in muscle and skin tension, altering the contact state at the interface between the sensor and the skin, which results in shifts in the angle of incident light. Such changes affect the path of light propagation within the skin, subsequently influencing the intensity of the diffusely reflected light received by the sensor. To address this issue, this study developed a wearable near-infrared optical sensor specifically designed for non-invasive analysis of body components. The photosensitive part of the sensor features a ring-shaped design, which not only increases the area that receives light but also allows for the average of the signal at 360 degrees, effectively reducing the anisotropic interference caused by variations in the angle of incident light. Monte Carlo simulations were used to analyze the performance differences between point detectors and the ring-shaped detector under conditions where the light incident angles varied randomly within the ranges of 1.2°, 2.5°, 5°, 15°, and 45°, as well as in a monotonic increase from 0° to 5°. The results demonstrated that the ring-shaped detector's signal-to-noise ratio is significantly higher than that of the point detector—approximately ten times greater. Accordingly, its detection limits for glucose are also lower, one-tenth those of the point detector. The ring-shaped detector not only reduces the anisotropic interferences caused by random variations in the angle of incidence but also shows stronger common-mode characteristics in interference received at two different source-detector separations. Therefore, using a pair of concentric ring-shaped detectors and differentially canceling the signals can further suppress interferences caused by changes in the angle of incidence. In human trials, subjects used ring-shaped and point detectors to collect signals under changes in body posture while fasting. The experimental results indicate that the ring-shaped detectors, combined with the differential method, effectively suppress interference caused by changes in the human-sensor contact state due to body posture changes, with signal variation ranging between 0.000 5 and 0.001 a. u., thus meeting the non-invasive blood glucose detection requirements of 0.5 to 1 mmol·L-1. In summary, the dual-ring shaped wearable detector proposed in this paper exhibits outstanding high signal-to-noise ratio performance in human testing, demonstrating its broad potential for application in non-invasive human body component analysis.
|
Received: 2024-04-18
Accepted: 2024-06-27
|
|
Corresponding Authors:
HAN Tong-shuai
E-mail: hts2014@tju.edu.cn
|
|
[1] Lim L, Nichols B, Rajaram N, et al. Journal of Biomedical Optics, 2011, 16(1): 011012.
[2] Groves R B, Coulman S A, Birchall J C, et al. Journal of the Mechanical Behavior of Biomedical Materials, 2013, 18: 167.
[3] Zyuryukina O A, Sinichkin Y P. Optics and Spectroscopy, 2019, 127(3): 555.
[4] Li C, Jiang J, Xu K. Journal of Innovative Optical Health Sciences, 2013, 6(1): 1350005.
[5] Nakhaeva I A, Zyuryukina O A, Mohammed M R, et al. Optics and Spectroscopy, 2015, 118(5): 834.
[6] Han T, Liu J, Liu R, et al. Applied Spectroscopy, 2022, 76(9): 1100.
[7] Joodaki H, Panzer M B. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2018, 232(4): 323.
[8] Waszczuk L, Ogien J, Pain F, et al. Journal of the European Optical Society-Rapid Publications, 2023, 19(2): 39.
[9] Lu Y, Han T S, Liu W B, et al. Journal of Biomedical Optics, 2023, 28(6): 065005.
[10] Liu J, Han T, Jiang J, et al. Biomedical Optics Express, 2019, 10(9): 4839.
[11] Zhang G, Mei Z, Zhang Y, et al. IEEE Transactions on Industrial Informatics, 2020, 16(11): 7209.
[12] Tanaka Y, Tajima T, Seyama M, et al. IEEE Sensors Journal, 2019, 20(8): 4453.
[13] Delpy D T, Cope M, van der Zee P, et al. Physics in Medicine & Biology, 1988, 33(12): 1433.
[14] Han G, Yu X, Xia D, et al. Applied Spectroscopy, 2017, 71(9): 2177.
[15] Wang L, Jacques S L, Zheng L. Computer Methods and Programs in Biomedicine, 1995, 47(2): 131.
[16] Yu L, Nina-Paravecino F, Kaeli D, et al. Journal of Biomedical Optics, 2018, 23(1): 010504.
[17] Bashkatov A N, Genina E A, Tuchin V V. Journal of Innovative Optical Health Sciences, 2011, 4(01): 9.
[18] Crisan D, Lupsor M, Boca A, et al. Indian Journal of Dermatology, Venereology and Leprology, 2012, 78(4): 519.
[19] Nakagawa N, Matsumoto M, Sakai S. Skin Research and Technology, 2010, 16(2): 137.
[20] Larin K V, Motamedi M, Ashitkov T V, et al. Physics in Medicine & Biology, 2003, 48(10): 1371.
|
[1] |
GE Qing, LIU Jin*, HAN Tong-shuai, LIU Wen-bo, LIU Rong, XU Ke-xin. Influence of Medium's Optical Properties on Glucose Detection
Sensitivity in Tissue Phantoms[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(05): 1262-1268. |
[2] |
LIU Wen-bo, LIU Jin, HAN Tong-shuai*, GE Qing, LIU Rong. Simulation of the Effect of Dermal Thickness on Non-Invasive Blood Glucose Measurement by Near-Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2699-2704. |
[3] |
WANG Nan1, 2, 3, XUAN Hong-wen3, LI De-hua3, NIE Yu-xin3. Measurement of Speed Distribution of Kerosene Flame by Using Photothermal Deflection Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3353-3357. |
[4] |
GE Qing, HAN Tong-shuai*, LIU Rong, LI Chen-xi, XU Ke-xin. Temperature Correction of NIR Reflectance Spectrum of Noninvasive Blood Glucose Measurement Based on EPO[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(05): 1483-1488. |
[5] |
CAO Hai-qing, HAN Tong-shuai, LIU Xue-yu, LIU Jin*. Extracting Linear Attenuance of Analyte in Turbid Scattering Media and Prediction Model Transfer Based Thereon[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(12): 3711-3717. |
[6] |
LI Gang1,2, BAO Lei1,2, ZHOU Mei3, LIN Ling1,2, LIU Rui4, ZHAO Chun-jie5* . New Method of Measuring Arterial Oxygen Saturation [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(01): 196-200. |
[7] |
LIN Ling1, LI Wei1, ZHOU Mei1, ZENG Rui-li2, LI Gang3, ZHANG Bao-ju4* . Application of EMD Algorithm to the Dynamic Spectrum Non-Invasive Measurement of Hemoglobin[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(08): 2106-2111. |
[8] |
LI Jia-xing1, 2, LIN Ling1, LI Zhe1, LI Gang1, SONG Wei3* . Noninvasive Measurement of Human Serum Protein Concentration by Near-Infrared Reflection Spectra for Tongue Inspection [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(11): 2992-2996. |
[9] |
ZHANG Bao-ju1, LEI Qing1, LI Gang2, LIN Ling2, WANG Hui-quan2, Jean Gao1 . Noninvasive Measurement of the Human RBC Concentration Based on BP NN Model [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(09): 2508-2511. |
[10] |
ZHANG Bao-ju1, JIA Ping1, ZHANG Zhi-yong2,3, LIN Ling2, MEN Jian-long2,4, LI Gang2* . PLS Analysis Used for Noninvasive Measurement of Human Neutrophiclic Granulocyte Based on Dynamic Spectrum Method [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(02): 466-469. |
[11] |
ZHANG Zhi-yong1, 2, MEN Jian-long1, 3, LI Gang1*, LIN Ling1 . Non-Invasive Measurement of Human Hemoglobin Concentration by Dynamic Spectrum Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(01): 150-153. |
|
|
|
|