Abstract Carbon Quantum Dots (CQDs), a class of zero-dimensional carbon nanomaterials with significant fluorescence properties, have become popular in biosensing application research in recent years. Lead comes from many sources in environments such as cosmetics and industrial pollution, and inhalation or ingestion of lead adsorbed on particulate matter can cause lead poisoning, which can cause various diseases, so point of care detection of lead ion (Pb2+) content is extremely important in clinical medical applications. Based on the fluorescence characteristics of carbon quantum dots, a new blue and red dual-emission ratio fluorescent probe was proposed for rapid detection of lead ion content, and the morphological structure and properties of the probe were characterized, detected and analyzed by transmission electron microscope, fluorescence spectroscopy and other means, and the optical properties and application feasibility of Pb2+ response probe were studied in depth. The double emission carbon point is calibrated by comparison with itself to improve the detection effect and sensitivity of the analyte concentration, and effectively avoid the interference of the external environment. This proportional fluorescent uses aqueous synthesis, which is simple and reproducible, and can rapidly respond to Pb2+ in just a few seconds. The detection process can be observed naked-eye from blue to red with only an ultraviolet lamp, which can be used for clinical point-of-care detection. In the concentration range of Pb2+ in line with current medical applications of 0~0.5 mg·L-1, the fluorescence intensity IBCDs/IRCDs has a good linear relationship with concentration, R2=0.987 44, and the detection limit is 0.013 6 mg·L-1. The progressive fluorescence sensing of the probe with Zn2+, Fe3+, K+ and other ten metal interfering ions showed that the probe had a good specific selection for Pb2+. The lead response was measured at different pH environments and incubation times to investigate probe stability.
|
Received: 2022-08-22
Accepted: 2022-11-21
|
|
Corresponding Authors:
CAO Hui-min
E-mail: huimincao@mail.scuec.edu.cn
|
|
[1] Ratnarathorn N, Chailapakul O, Dungchai W, et al. Talanta, 2015, 132: 613.
[2] Yuan Zhiqin, Peng Meihua, He Yan, et al. Chemical Communications, 2011, 47: 11981.
[3] Wang Yuedan, Zhou Zhou, Qing Xing, et al. Analytical and Bioanalytical Chemistry, 2016, 408(21): 5779.
[4] Fatima Ezzahra Salih, Aicha Ouarzane, Mama El Rhazi, et al. Arabian Journal of Chemistry, 2017, 10(5): 596.
[5] Thirumalai M, Kumar S N, Prabhakaran D, et al. Journal of Chromatography A, 2018, 1569: 62.
[6] Duan Hualing, Zhang Ningning, Gong Zhenbin, et al. Spectrochimica Acta Part B: Atomic Spectroscopy, 2016, 120: 63.
[7] Zhao Qin, Rong Xiaolong, Chen Li,et al. Talanta, 2013, 114: 110.
[8] Nerea De Acha, César Elosúa, Jesús M Corres, et al. Sensors, 2019, 19(3): 599.
[9] Zhang Xuejie, Wang Xiangtao, Qiu Hanhong, et al. Colloids and Surfaces B: Biointerfaces, 2020, 189: 110876.
[10] Vinayak Sahu, Fahmida Khan. Heliyon, 2020, 6(5): e03957.
[11] Wang Chuanxi, Wu Jiapeng, Jiang Kaili, et al. Sensors and Actuators B: Chemical, 2017, 238: 1136.
[12] He Guili, Shu Mengjun, Yang Zhi, et al. Applied Surface Science, 2017, 422: 257.
[13] Zubair M S H Khan, Raja Saifu Rahman, Shumaila, et al. Optical Materials, 2019, 91: 386.
[14] Sajad Moradi, Komail Sadrjavadi, Negin Farhadianb, et al. Journal of Molecular Liquids, 2018, 259: 284.
[15] Pramod Kumar Mehta, Jong yong Jeon, Ki Ryu, et al. Journal of Hazardous Materials, 2022, 427: 128161.
[16] Gao Zhikun, Hao Tongfan, Fang Qunxiang, et al. Methods and Applications in Fluorescence, 2021, 9(1): 015004.
[17] SHI Ji-yong, LI Wen-ting, HU Xue-tao, et al(石吉勇, 李文亭, 胡雪桃, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2019, 39(12): 3925.
[18] Shu Yun, Dai Tao, Ye Qiuyu, et al. Journal of Fluorescence, 2021, 31(6): 1947.
[19] LIAN Jie, REN Yi-fei, YANG Rui-qin, et al(廉 洁, 任翼飞, 杨瑞琴, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2020, 40(3): 804.
[20] Li Wenting, Hu Xuetao, Li Qian, et al. Food Chemistry, 2020, 320: 126623.
[21] Wang Haiqian, Yang Liang, Chu Suyun, et al. Analytical Chemistry, 2019, 91(14): 9292.
[22] Lu Hongzhi, Yu Chunwei, Xu Shoufang. Sensors and Actuators B: Chemical, 2019, 288: 691.
[23] Yeji Kim, Jongsung Kim. Optical Materials, 2020, 99: 109514.
[24] Xavier S S J, Siva G, Annarajb J, et al. Sensors and Actuators B: Chemical, 2018, 259: 1133.
|
[1] |
HE Yan-ping, WANG Xin, LI Hao-yang, LI Dong, CHEN Jin-quan, XU Jian-hua*. Room Temperature Synthesis of Polychromatic Tunable Luminescent Carbon Dots and Its Application in Sensitive Detection of Hemoglobin[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3365-3371. |
[2] |
CHAI Lin-lin, Areyi Mulati, Shawket Abliz*. Analysis the Adsorption Behaviors of Acetic Acid Modified Sand Grains for Lead Ions by Atomic Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2775-2778. |
[3] |
HAN Zhao-xia1, 2, 3*, YANG Zhi-jin1, ZHANG Zhi-hong1, DING Shu-hui1, ZHANG Da-wei1, 2, 3, HONG Rui-jin1, 2, 3, TAO Chun-xian1, 2, 3, LIN Hui1, 2, 3, YU De-chao1, 2, 3. Preparation of Full-Color Carbon Quantum Dots and Their Application in WLED[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1358-1366. |
[4] |
LÜ Chun-qiu1, SI Lu-lu1, PAN Zhao-jin2, LIANG Yang-lin1, LIAO Xiu-fen2, CHEN Cong-jin2*. Fast and Ratiometric Detection of Dimethoate Via the Dual- Emission Center Nitrogen-Doped Carbon Quantum Dots[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(02): 468-474. |
[5] |
LIU Yu-ying1, 2, WANG Xi-yuan1, 2*, MEI Ao-xue1, 2. Green Preparation of Biomass Carbon Quantum Dots for Detection of Cu2+[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(01): 248-253. |
[6] |
XU Yi-fei, LIU Lu, SHI Shi-kao*, WANG Yue, PAN Yu-jing, MA Xing-wei. Spectroscopic Properties of Carbon Quantum Dots Prepared From Persimmon Leaves and Fluorescent Probe to Fe3+ Ions[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(08): 2418-2422. |
[7] |
SHAO Ke-man, FU Gui-yu, CHEN Su-yan, HONG Cheng-yi, LIN Zheng-zhong*, HUANG Zhi-yong*. Preparation of Molecularly Imprinted Fluorescent Probe for Rare Earth Complex and Determination of Malachite Green Residue[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(03): 808-813. |
[8] |
HU Jing-jing, TONG Chang-lun*. Study on the Interaction Between Carbon Quantum Dots and Human Serum Albumin by Spectroscopic Methods[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(04): 1107-1113. |
[9] |
JIA Hui-jie, ZHU Ning, GAO Yuan-yuan, WANG Ya-qi, SUO Quan-ling*. Effect of Substituent Structure of Benzothiazole Probe on Recognition to Metal Ion[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3594-3598. |
[10] |
MA Hong-yan,WANG Jing-yuan, ZHANG Yue-cheng*, YANG Xiao-jun, CHEN Xiao-li. Determination of Dopamine by Fluorescence Quenching-Recovery Method with Peanut Carbon Quantum Dots as Probe[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(04): 1093-1098. |
[11] |
LIAN Jie1, REN Yi-fei2, YANG Rui-qin1*, HAO Hong-xia3. Rapid Detection System of 2,4,6-Trinitrophenol (TNP) Based on Fluorescent Probe[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(03): 804-808. |
[12] |
SHI Ji-yong, LI Wen-ting, HU Xue-tao, SHI Yong-qiang, ZOU Xiao-bo*. A New Ratiometric Fluorescence Probe Based on CuNCs and CQDs and Its Application in the Detection of Hg2+[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(12): 3925-3931. |
[13] |
YANCHEN Zhou-yan, HONG Cheng-yi, LIN Zheng-zhong, HUANG Zhi-yong*. Detection of Hg(Ⅱ) in Water with Ratio Fluorescent Paper Strip Based on Carbon Dots and RhB[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(11): 3426-3432. |
[14] |
HU Xue-tao, SHI Ji-yong, LI Yan-xiao, SHI Yong-qiang, LI Wen-ting, ZOU Xiao-bo*. Sensitive Determination of Trypsin in Urine Using Carbon Nitride Quantum Dots and Gold Nanoclusters[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(09): 2901-2906. |
[15] |
CHEN Zhu-ling, LIN Min-xiu, SONG Zhi-ping, GUO Liang-qia*, CHEN Yi-ping. Study of Direct Fluorescence Quenching of Graphitic Carbon Nitride for the Detection of Iodine Ions[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(07): 2029-2033. |
|
|
|
|