Quality Control to the Detection of Gross Alpha Activity in Drinking Water by Low-Background Gross Alpha/Beta Counter |
MAO Li, LI Rong-pei, LIU Xin, SU Hui-lan* |
Department of Public Health, Chengdu Medical College, Chengdu 610500, China |
|
|
Abstract The gross alpha activity assay generally serves as one of screening approaches on gross radiation level to avoid the cumbersome radionuclide identification at low radioactivity level. Since the radioactivity investigation in China showed that the gross alpha activity in drinking water maintained a low level, the high-efficient quality control in laboratory should be provided in gross alpha activity assay to guarantee the accuracy. In this experiment, the low-background gross alpha/beta counter was employed with alpha scintillation as probe to detect the gross alpha activity in drinking water. The energy of alpha particles emitted from analyte sample was absorbed by alpha scintillation and transferred to organic scintillation with fluorescence emission on the probe, by which the nuclear radiation was converted into the flicker of fluorescence. The number of flickers is proportional to the number of kernel decay per unit time for counting the alpha particles numbers emitted from analyte sample layer. At first, the electroplating source with alpha particle emissivity of 2~20 particles numbers per second in 2π direction vector was used to determinate the alpha background counting rate (CPS). Then the alpha background count, the detection efficiency of work source (η), the common background beta to alpha ratio (Fα) were optimized in the experiment. Upon these optimized parameters, the standard source counting rate (ε) was calculated by fitting calibration curve. Finally, combining the value of CPS and ε, the gross alpha volume activity in controlled water samples was calculated as mathematical model. Based on these data statistics, the quality control on alpha background count, alpha count of standard source and the gross alpha volume activity were investigated for evaluating the influence of CPS and ε on the quality control of gross alpha volume activity assay. The results showed that while the spread sample with the density of 4 mg·cm-2 was placed for 24 h and measured with 239Pu as work source and 241Am as standard source for 60 min, the CPS could be obtained as 0.000 37 s-1 upon the η of 94.34%, the Fα of 0.41% and ε of 7.25% (Y=1.323X-5.285,R2=0.991 5). And the alpha backgrounds of 40 blank panel samples count over the range of -1.61~5.82. Among these samples, 33 of samples count in the controlled scope of upper auxiliary limit (UAL) and lower auxiliary limit (LAL). 2 of samples count in the controlled scope of upper warning limit (UWL) and UAL. 3 of samples count in the controlled scope of lower warning limit (LWL) and LAL. 2 of samples count in the controlled scope of UWL and upper control limit (UCL). The alpha background was well controlled. And the alpha particle numbers of 24 standard source samples count over the range of 523.7~644.3. Among these samples, 14 of samples count in the controlled scope of UAL and LAL. 5 of samples count in the controlled scope of UWL and UAL. 5 of samples count in the controlled scope of LWL and LAL. The alpha count of standard source was well controlled. Moreover, the gross alpha volume activity of 20 drinking-water samples distributed over the range of 0.007 91~0.057 86 Bq·L-1. Among these water samples, 11 of samples dispersed in the controlled scope of UAL and LAL. 5 of samples dispersed in the controlled scope of UWL and UAL. 3 of samples dispersed in the controlled scope of LWL and LAL. Only one sample dispersed in the scope of LWL and lower control limit (LCL). The gross alpha activity detection was well controlled in drinking-water samples. Therefore, while the gross alpha activity at low level was detected by using alpha scintillation probe, controlling two main uncertainty source of alpha background and standard source counting rate was an effective strategy in quality control of gross alpha activity assay in laboratory.
|
Received: 2018-12-07
Accepted: 2019-04-10
|
|
Corresponding Authors:
SU Hui-lan
E-mail: tiantian1986315@126.com
|
|
[1] Seiler Ralph. Science of the Total Environment, 2016, 568: 1010.
[2] Sarvajayakesavalu Suriyanarayanan, Laksh-Minarayanan Divya, George Jessen, et al. Groundwater for Sustainable Development,2018, 6: 164.
[3] JU Jin-xin, XUE Ru, CHEN Er-dong(鞠金欣, 薛 茹, 陈尔东). Chinese Journal of Radiological Health(中国辐射卫生),2016, 25(2): 163.
[4] XU Yi-ming(许一明). Journal of China Hydrology (水文),2018, 38(3): 73.
[5] YU Li(于 利). Chinese Journal of Radiological Health(中国辐射卫生),2013, 22(3): 293.
[6] ZHAO Qing, QIU Xiang-ping, LIU Hao-ran(赵 清, 邱向平, 刘浩然). Chemical Analysis and Meterage(化学分析计量),2015, 24(5): 7.
[7] WANG Yan-jun, LUO Wei-li, WU Jia-long, et al(王延俊, 罗伟立, 邬家龙, 等). Chinese Journal of Health Laboratory Technology(中国卫生检验杂志),2017, 27(9): 1323.
[8] SUN Jian-yi(孙建义). China Resources Comprehensive Utilization(中国资源综合利用),2018, 36(4): 11.
[9] HUANG Hua, FU Yong-ming, YANG Ya-xin, et al(黄 华, 付勇明, 杨亚新, 等). Journal of East China University of Science and Technology (华东理工大学学报自然科学版),2016, 39(4): 369.
[10] LÜ Wen-hui, YI Hong-chang, ZENG Zhi(吕汶辉, 衣宏昌, 曾 志, 等). Nuclear Electronics and Detection Technology(核电子学与探测技术),2018, 38(2): 206.
[11] Fiserovaa Lucie, Janda Jiri. Journal of Environmental Radioactivity,2018, 195: 54.
[12] GUO Qian, DONG Jin-yang, HAO Yan-min, et al(郭 倩, 董晋阳, 郝雁敏, 等). Journal of Shanxi Normal University Natural Science Edition (山西师范大学学报自然科学版),2016, 30(4): 57.
[13] Janda Jiří, Tichá Jitka. Journal of Environmental Radioactivity,2018, 192: 181.
[14] GONG Jin-yu(龚锦瑜). Guangdong Chemical Industry (广东化工),2018, 45(11): 244. |
[1] |
WANG Gui-xia, SU Jun-hong*, XU Jun-qi, SHI Kai. Misjudgment Elimination Method on Identification of Thin Film Damage by Plasma Flash Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(11): 3341-3346. |
[2] |
GE Jin-man1,2, SU Jun-hong1,2*, CHEN Lei1, Lü Ning2. A New Method for Measurement of Laser-Induced Damage Threshold[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1296-1299. |
[3] |
LIU Sheng1, 2, HUANG Chao-qun1, 3, SHEN Cheng-yin1, 3, CHU Yan-nan1, 3* . Asymmetric Control Method for Ion Shutter and the Resolution Improvement of Ion Mobility Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(11): 2881-2885. |
|
|
|
|