Rapid Determination of Total Phosphorus by Ultrasonic Assisted Sample Digestion-Spectrum Analysis
WEI Kang-lin1, WANG Fei1*, CHEN Ming1, WEN Zhi-yu2, MO Zhi-hong2
1. Department of Eelectronic Information Science and Technology, College of Science, China Three Gorges University, Yichang 443002, China 2. Microsystem Research Center,Chongqing University,Chongqing 400044, China
Abstract:Aiming at the technological shortage of national standard method for the determination of total phosphorus, a rapid determination method of total phosphorus based on ultrasonic assisted sample digestion-spectrum analysis was put forward, and the on-line analysis experiment system was designed. Relying on the experiment system, the experimental method and technology was studied. In view of the actual environmental water samples, contrast test experiment with the national standard method for determination method of total phosphorus was carried on. The experimental results showed that the digestion rate of ultrasonic assisted sample digestion using fenton reagents could reach 97%~100% in 13.5 minutes, and the determination method could complete one copy of sample analysis within 16 minutes. This determination method can solve national standard method’s technical problems. All of this research work provides the important experimental basis and technical support for the development of the rapid on-line monitoring instrument for determination of total phosphorus.
[1] National Environmental Protection Bureau(国家环境保护局). GB 11893—89. Water Quality-Determination of Total Phosphorus-Ammonium Molybdate Spectrophotometric Method(水质总磷的测定—钼酸铵分光光度法). Beijing: China Standard Press(北京:中国标准出版社), 1989. 188. [2] Shyla B, Mahadevaiah, Nagendrappa G. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2011, (78): 497. [3] Michael V Storey. Water Research, 2011, (45): 741. [4] Brady S Gentle, Peter S Ellis, et al. Analytica Chimica Acta, 2010, 674: 117. [5] Hrynczyszyn P, Jastrzebska A. Analytica Chimica Acta, 2010, (673): 73. [6] Ganesh S,Khan Fahmida, Ahmed M K. Water Science and Technology, 2012, (66): 2653. [7] Michael V Storey. Water Research,2011, 45(2): 741. [8] CAO Yan-ping,YUAN Ying-mao,ZHU Yu-chen(曹雁平,袁英髦,朱雨辰). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2012, 32(5): 1320. [9] Claudia E Domini. Ultrasonics Sonochemistry, 2009, 16(5): 686. [10] Fernanda V M Pontes, Bruna A de O Mendes, Evelyn M F de Souza. Analytica Chimica Acta, 2010, 659(2): 55. [11] Carrera Monica,Canas Benito,Lopez-Ferrer Daniel. Analytical Chemistry, 2011, 83(14): 5688. [12] Shin Seongjae,Yang Hyo-jik, Kim Jinhee. Analytical Biochemistry, 2011, 414(1): 125. [13] Cui Zhiping, Hu Xiaoli. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2011, (83): 1.