Research on Serum Prostate-Specific Antigen Measurement by Characteristic Spectral Absorption Method
ZHU Jian-ming1, 2, CHEN Zhen-cheng2
1. School of Geosciences and Info-Physics, Central South University, Changsha 410083, China 2. School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
Abstract:A serum prostate-specific antigen (PSA) measurement method was studied using immunochromatography-based colloidal gold-marked test-strips and characteristic spectral absorption method. Some LEDs in the range from 520 to 535 nm irradiated the test-strips sampled by PSA, and then a photodiode in the range from 520 to 540 nm measured the reflex light at the specific area. Accordingly, the absorbency of the strip could be calculated, then the relationship between PSA level and strip absorbency could be ascertained by linear fit method. The experimental measurement system was calibrated by different PSA standard solutions in this research. As a result, in the range between 5 to 50 ng·mL-1, the levels of PSA have a linear relationship with the absorbency of test-strips. Some experiments were completed by 21 different PSA standard solutions within that range, and then the correlation coefficient of the results is equal to 0.910, which proves that the proposed method for serum PSA level measurement is feasible.
[1] WANG Zhao-xia, WANG Yan, ZHANG Wei-dong(王朝霞, 王 燕, 张维东). The Practical Journal of Cancer(实用癌症杂志), 2009, 24(2): 205. [2] Lane J A, Hamdy F C, Martin R M, et al. European Journal of Cancer, 2010, 46(17): 3095. [3] JI Guo-yi, WANG Wei-hua, ZHAO Wei, et al(计国义, 王伟华, 赵 微, 等). Chinese Journal of Laboratory Diagnosis(中国实验诊断学), 2009, 13(1): 100. [4] Kang D Y, Jang Y H, Lee J H, et al. Current Applied Physics, 2009, 9(2): 33. [5] Cao C, Li X, Lee J, et al. Biosensors and Bioelectronics, 2009, 24(5): 1292. [6] Kumar V M, Hassan M I, Singh A K, et al. Clinica Chimica Acta, 2009, 403(1-2): 17. [7] PAN Gao-yun, XIA Jian-ke, ZHU Zhang-qian, et al(潘高云, 夏建克, 朱张茜, 等). Chinese Primary Health Care(中国初级卫生保健), 2010, 24(2): 126. [8] CHEN Xi, SONG Wei-hua(陈 曦, 宋卫华). Labeled Immunoassays and Clinical Medicine(标记免疫分析与临床), 2010, 17(1): 46. [9] Schalken J A. European Urology Supplements, 2009, 8(3): 97. [10] Vugt H A, Roobol M J, Venderbos L D, et al. European Journal of Cancer, 2010, 46(3): 669. [11] Hara N, Koike H, Nobushita T, et al. Urologic Oncology: Seminars and Original Investigations, 2010, 28(4): 355. [12] Dwek M V, Jenks A, Leathem A. Clinica Chimica Acta, 2010, 411(23-24): 1935. [13] Korfage I J, Bergh R, Essink M L. European Journal of Cancer, 2010, 46(17): 3073. [14] Osman N I, Chow K, Ng W, et al. British Journal of Medical and Surgical Urology, 2010, 3(4): 167. [15] Matapatara W, Likitthanaset M. Journal of Biotechnology, 2010, 150(1): 426. [16] Byzova N A, Zvereva E A, Zherdev A V, et al. Talanta, 2010, 81(3): 843. [17] Gimeno C, Costa E, Navalpotro D, et al. Diagnostic Microbiology and Infectious Disease, 2010, 68(1): 80. [18] CHEN Zhen-cheng, ZHU Jian-ming(陈真诚, 朱健铭). Journal of Guilin University of Electronic Technology(桂林电子科技大学学报), 2010, 30(5): 497. [19] LI Hui, LIN Qi-zhong, WANG Qin-jun, et al(李 慧, 蔺启忠, 王钦军, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2010, 30(9): 2433. [20] Emery X. Computers & Geosciences, 2010, 36(9): 1150. [21] Dornheim H, Brazauskas V. Journal of Statistical Planning and Inference, 2011, 141(4): 1422. [22] Strobach P. Journal of Computational and Applied Mathematics, 2011, 235(9): 3033. [23] CHEN Zhen-cheng, JIN Xing-liang, ZHU Jian-ming, et al(陈真诚, 金星亮, 朱健铭, 等). J. Cent. South Univ. Technol.(中南大学学报·自然科学版), 2009, 16: 982. [24] ZHU Jian-ming(朱健铭). Changsha: Central South University(长沙:中南大学), 2010, 6: 35.