1. Department of Chemistry,Capital Normal University,Beijing 100048,China 2. Beijing Obstetrics and Gynecology Hospital,Capital Medical University,Beijing 100006,China
Abstract:Near-infrared spectroscopy combined with chemometrics methods for diagnosis of cancer has been reported in literatures. In our study, the NIR spectra of 77 specimens of different physiological stages of endometrium were collected. Spectral data were pretreated firstly by multiplicative scatter correction (MSC), orthogonal signal correction (OSC), and both of them, respectively, and then by SG smoothing. Latin partition method was used to select 3/4 samples as a training set, and the other 1/4 samples for test set. Support vector machine (SVM) model was built for classification, and the classification results was compared with that of partial least squares (PLS) model based on the same pretreatment methods. Samples of malignant, hyperplasia and normal endometrium were classified better by SVM (classification accuracy was 92%) than PLS (classification accuracy was 90%). The results suggested that classification accuracy was affected by pretreatment methods and models. SVM combined with endometrial tissue near infrared spectroscopy is expected to develop into a new approach to tumor diagnosis.
翟 玮1,相玉红1,代荫梅2,张家进1,张卓勇1* . 基于近红外光谱和支持向量机的子宫内膜癌早期诊断研究 [J]. 光谱学与光谱分析, 2011, 31(04): 932-936.
ZHAI Wei1,XIANG Yu-hong1,DAI Yin-mei2,ZHANG Jia-jin1,ZHANG Zhuo-yong1* . Early Stage Diagnosis of Endometrial Cancer Based on Near Infrared Spectroscopy and Support Vector Machine . SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(04): 932-936.
[1] SUN Wen-chao(孙文超). J. Int. Obstet. Gyneco.(国际妇产科学杂志),2009,36(4):275. [2] Zhang Yan,Liu Zhiwei,Yu Xinchun,et al. Gynecologic Oncology,2010,117:41. [3] YU Mei,ZHEN Jing-ran(俞 梅, 甄璟然).Journal of China Prescription Drug (中国处方药),2009,3:72. [4] Kondepati V R,Keese M,Mueller R,et al. Vibrational Spectroscopy,2007,44:236. [5] Kondepati V R,Keese M,Mueller R,et al. Vibrational Spectroscopy,2007,44:56. [6] Kondepati V R,Oszinda T,Heise H M,et al. Anal. Bioanal. Chem.,2007,387:1633. [7] Bhushan K R,Misra P,Liu F B. J. Am. Chem. Soc.,2008,130(52):17648. [8] ZHAO Li-ting,XIANG Yu-hong,DAI Yin-mei,et al(赵立婷,相玉红,代荫梅,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2010,30(4):901. [9] Vapnik V. Statistical Learning Theory. New York:John Wiley,1998. [10] DENG Nai-yang,TIAN Ying-jie(邓乃扬,田英杰). Support Vector Machine——Theory,Algorithm and Expanding(支持向量机——理论、算法与拓展). Beijing:Science Press(北京:科学出版社),2009. [11] Geladi P, Macdou G D, Martens H. Applied Spectrosc., 1985, 39(3): 491. [12] LU Wan-zhen(陆婉珍). Modern Near Infrared Spectroscopy Analytical Technology(Second Edition)(现代近红外光谱分析技术,第2版). Beijing:China Petrochemical Press(北京:中国石化出版社),2007. [13] Wold S,Antti H,Lindgren F. Chemom. Intell. Lab. Syst.,1998,44:175. [14] CHU Xiao-li,YUAN Hong-fu,LU Wan-zhen(褚小立,袁洪福,陆婉珍). Progress in Chemistry(化学进展),2004,16(4):528. [15] Andersson C A. Chemometrics and Intelligent Laboratory Systems,1999,47:51. [16] Westerhuis J A,Jong S,Smilde A K. Chemometrics and Intelligent Laboratory Systems,2001,56:13.