Rapid Analysis of Mercury in Sediments by Laser Ablation Inductively Coupled Plasma Mass Spectrometry
TAO Guan-hong1, FUJIKAWA Yoko2
1. Department of Chemistry and Chemical Engineering, Suzhou University, Suzhou 215006, China 2. Research Reaction Institute, Kyoto University, Osaka-fu 590-0494, Japan
Abstract:Laser ablation inductively coupled plasma mass spectrometry was used for the rapid analysis of mercury in sediment samples. The ground samples were simply briquetted prior to laser ablation. The effects of internal standardization, particle size and elemental speciation on the analytical performance were investigated. Direct analysis of sediment samples without internal standardization could yield satisfactory results. Elemental speciation and particle size within the studied range did not significantly affect the measurements. The calibration curve was obtained simply by analyzing one soil and two sediment reference materials. With the proposed LA-ICP-MS system, a detection limit of 0.02 mg·kg-1 was achieved with a sample through put of 10 h-1. Analytical results of sediment samples using the current system were in good agreement with those by isotope dilution hydride-generation ICP-MS.
Key words:Laser ablation;Inductively coupled plasma mass spectrometry;Mercury;Sediments
[1] Vandecasteele C, Block C B. Modern Methods for Trace Elements Determination, Wiley, Chichester, 1993. [2] Houk R S, Fassel V A, Flesch G D, Svec H J, Gray A L, Tayler C E. Anal. Chem., 1980, 52: 2283. [3] Durrant S F. J. Anal. At. Spectrom., 1999, 14: 1385. [4] LUO Yan, HU Sheng-hong, LIU Yong-sheng, GAO Shan, LIN Shou-lin(罗 彦,胡圣虹,刘勇胜, 高 山, 林守麟). Chinese J. of Anal. Chem.(分析化学),2001, 29(11): 1345. [5] CHEN Hang-ting, CAO Shu-qin, ZENG Xian-jin(陈杭亭,曹淑琴,曾宪津). Chinese J. of Anal. Chem.(分析化学),2001, 29(5): 592. [6] Gunther D. Anal. Bioanal. Chem., 2002, 372: 31. [7] WEI Gang-jian, LIANG Xi-rong, LI Xian-hua, ZHAO Quan-hong, SHAO Lei, ZHU Zhao-yu(韦刚健, 梁细荣, 李献华, 赵泉鸿, 邵 磊, 朱照宇). Geochimica(地球化学), 2002, 31(1): 35. [8] Baker S A, Bi M, Aucelio R Q, Smith B W, Winefordner J D. J. Anal. At. Spectrom., 1999, 14: 19. [9] Durrant S F,Ward N I. Fresenius'J. Anal. Chem., 1993, 345: 512. [10] Guo X,Lichte F E. Analyst, 1995, 120: 2707. [11] Chen Z, Doherty W,Gregoire D C. J. Anal. At. Spectrom., 1997, 12: 653. [12] Kiceniuk J W, Ray S. Analysis of Contaminants in Edible Aquatic Resources, New York:VCH, 1994. [13] Fordham P J, Gramshaw J W, Castle L, Crews H M, Thompson D, Parry S J, McGurdy E D. J. Anal. At. Spectrom., 1995, 10: 303. [14] Chenery S, Cook J M. J. Anal. At. Spectrom., 1993, 8: 299. [15] Gunther D, Cousin H, Magyar B, Leopold I. J. Anal. At. Spectrom., 1997, 12: 165. [16] Kudo A, Fujikawa Y, Mitui M, Sugahara M, Tao G, Zheng J, Sasak T, Miyahara S, Muramatsu T. Water Sci. Tech., 2000, 42, 177.