Abstract:Simultaneous online measurement of gas concentration and velocity can be realized by tunable diode laser absorption spectroscopy (TDLAS) technique and optical signal cross-correlation method. The fundamental and relative factors of gas concentration and velocity measurement are described in the present paper. The spectral lines of NH3 used for gas sensing at communication band in near infrared range were selected and analyzed by the calculation based on the HITRAN database. In the verification experiment, NH3 and N2 were mixed by two mass flow meters and sent to flow through the quartz tube 0.016 m in inner diameter and 1 m in length at normal temperature and pressure. The spectral line located at 6 548.7 cm-1 was scanned at high frequency by the diode laser of 15 MHz linewidth and 1 cm-1 tunable range with no mode hoppings. The instantaneous NH3 absorbance was obtained using direct absorption method and the gas concentration was calculated. At the same time, the non-intrusive optical absorption signal cross-correlation method was utilized to obtain two concentration signals from two adjacent detectors mounted along the gas tube. The corresponding transit time of gas passing through the detectors was calculated by cross-correlation algorithm, and the average gas velocity was inferred according to the distance between the two detectors and the transit time. The relative errors were less than 7% for the gas concentration measurement, and less than 10% for the gas velocity measurement. Experimental results were proved to be of high precision and good repeatability in the lab. The feature of fast response and capacity immune to the in-situ disturbance would lead to a potential in industry application for the real time measurement and control of gas pollutant emission in the future.
张春晓,王 飞*,李 宁,严建华,池 涌,岑可法 . 可调谐半导体激光吸收光谱技术光信号相关法氨气浓度流速同时测量[J]. 光谱学与光谱分析, 2009, 29(10): 2597-2601.
ZHANG Chun-xiao, WANG Fei*, LI Ning, YAN Jian-hua, CHI Yong, CEN Ke-fa . Ammonia Gas Concentration and Velocity Measurement Using Tunable Diode Laser Absorption Spectroscopy and Optical Signal Cross-Correlation Method. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29(10): 2597-2601.
[1] GAO Shan-hu, LIU Wen-qing, LIU Jian-guo(高山虎,刘文清,刘建国). Chinese Journal of Quantum Eletronics(量子电子学报), 2006,23(3):388. [2] Reid J, Labrie D. Appl. Phys. B, 1981, 26: 203. [3] KAN Rui-feng, LIU Wen-qing, ZHANG Yu-jun(阚瑞峰,刘文清,张玉钧). Chinese Journal of Laser(中国激光), 2005, 32(9): 1217. [4] XIA Hui, LIU Wen-qing, ZHANG Yu-jun, et al. Chinese Optics Letters, 2008, 6(6): 437. [5] LIU He-lai, ZENG Zong-yong, LIU Wen-qing(刘和来,曾宗泳,刘文清). Optical Technique(光学技术), 2006,32(6):922. [6] ZHOU Jie, YUAN Zhen-fu, CEN Ke-fa(周 洁,袁镇福,岑可法) . Proceedings of the Chinese Society for Electrical Engineering(中国电机工程学报), 2003,23(1):185. [7] Lundsberg-Nielsen L, Hegelund F, Nicolaisen F M. J. Mol. Spectros., 1993, 162: 230. [8] Mihallea R M, Baer D S, Hanson R K. Applied Optics, 1997, 36(33): 8745. [9] Webber M E, Baer D S, Hanson R K. Applied Optics, 2001, 40(12): 2031. [10] Tin g-I Wang, Ochs G R, Lawrence R S. J. Appl. Opt., 1981, 20: 4073. [11] CHEN Dong, LIU Rui-feng, ZHANG Yu-jun, et al. Chinese Optics Letters, 2007, 5(2): 121. [12] Besson J P, Schilt S, Rochat E, et al. Applied Physics B, 2006, 85: 323. [13] LI Ning,YAN Jian-hua, WANG Fei(李 宁,严建华,王 飞). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2008,28(08):1708. [14] KAN Rui-feng, LIU Wen-qing, ZHANG Yu-jun, et al. Chinese Optics Letters, 2006, 4(2): 116. [15] Weidmann D, Hamdouni A, Lourtois D. Applied Physics B, 2001, 73: 85.