Abstract:Near-infrared (NIR) spectroscopy has been widely used in agriculture, medicine, petrochemical and food industries. However, the measurement precision of NIR spectroscopy is adversely affected by the change in external conditions. Among these influence factors, temperature fluctuation is harder to be controlled than other conditions such as contact pressure and measurement position. Based on the displacement effect between solvent and solute molecules in solution, a reference-wavelength method for temperature measurement of solution is presented in the present paper. The theoretical expression of the method was introduced. The experiment was designed to measure the spectra of glucose aqueous solution under different temperatures, and the effect of eliminating the temperature disturbance was evaluated. When the temperature and solute concentration of solution change simultaneously, the absorbency difference value at reference-wavelength is insensitive to solute concentration, and is totally affected by temperature fluctuation. Therefore, according to the absorbance difference, the actual temperature of the sample can be calculated. The regression model of temperature measurement was established, and the solution temperature was calculated based on this model. The information about temperature can be acquired exactly by reference-wavelength method, and the experimental results showed that the average error of calculated temperature is 0.03 ℃.
[1] LIU Wei-ling, ZHANG Si-xiang, YU Qi-lian, et al(刘伟玲,张思祥,虞启琏,等). Analytical Instrumentation (分析仪器), 2004, (1): 47. [2] Corbela E, Cozzolino D. Journal of Near Infrared Spectroscopy, 2005, 13(2): 63. [3] Inon Fermando A, Llario Rafael, Garrigues Salvador, et al. Analytical and Bioanalytical Chemistry, 2005, 382(7): 1549. [4] Kim Minjin, Lee Young-Hak, Han Chonghun. Computers and Chemical Engineering 2000, 24(2): 513. [5] Katsuhiko Maruo, Tomohiro Oota, Mitsuhiro Tsurugi, et al. Applied Spectroscopy, 2006, 60(4): 441. [6] Lee Jangwoen, Saltzman D J, Cerussi A E, et al. Physiological Measurement, 2006, 27: 757. [7] DeBraekeleer K, Cuesta Sanchez F, Hailey P A, et al. Journal of Pharmaceutical Biomedical Analysis, 1998, 17(1): 141. [8] Jensen Peter Snoer, Bak Jimmy, Andersson-Engels Stefan. Applied Spectroscopy, 2003, 57(1): 28. [9] Peinado A C, Van Den Berg F, Blanco M, et al. Chemometrics and Intelligent Laboratory Systems, 2006, 83(1): 75. [10] Masatoshi Tarumi, Mitsunori Shimada, Tomoya Murakami, et al, Physics in Medicine and Biology, 2003, 48: 2373. [11] Eugenio H Otal, Fernando A. Inón, et al. Applied Spectroscopy, 2003, 57(6): 661. [12] Naoto Kakuta, Hidenobu Arimoto, Hideyuki Momoki, et al. Applied Optics, 2008, 47(13): 2227. [13] Matthias Kohl, Matthias Essenpreis, Mark Cope. Physics in Medicine and Biology, 1995, 40: 1267. [14] Airat K Amerov, Chen Jun, Mark A Arnold. Applied Spectroscopy, 2004, 58(10): 1195. [15] Chen Wenliang, Xu Kexin, Li Yu, et al. Chinese Optics Letters, 2007, 5(12): 706.