1. Xinjiang Technical Institute of Physics & Chemistry, Chinese Academy of Sciences, Urumqi 830011, China 2. Graduate School of Chinese Academy of Sciences, Beijing 100039, China
Abstract:In the present paper, the material of alkaline-earth metal sulphide doped with two kinds of rare-earth metal ions was prepared by carbon reduction method, and the radiation characteristics of optically stimulated luminescence of this material are described. The PMMA dosimeter films were taken into the radiation source,then the fluorescence signal from the dosimeter films was measured with the test system build by ourselves. The relation between the radiation dose and the fluorescence intensity of the dosimeter films was obtained. The measuring range of the dosimeter was from 0.01 to 1 000 Gy (5 orders of magnitude), and there is a good linear relationship between stimulated luminescence signal value of the material and the dose. It demonstrates that this device has a good prospect. This equipment is relatively simple, small in size and low in power consumption. This device is suitable for measuring the space radiation dose exploration.
[1] Dusseau L, Plattard D, Vaille J R, et al. IEEE Transactions on Nuclear Science, 2000, 47: 2412. [2] Holmes-Siedle A, Adams L. Handbook of Radiation Effects. USA: Oxford University Press, 2002, 342. [3] Fowler J F, Attix F H. Radiation Dosimetry, 1966, 2: 241. [4] Lenard P, Schmidt F, Tomaschek R. Phosphoreszenz und Fluoreszenz. Akademische Verlagsgesellschaft Press, 1928. 143. [5] Iida H. Nippon Genshiryoku Gakkaishi, 1963, 5: 412. [6] LIU Qiu-jiang, CHEN Chao-yang, FAN Yan-wei, et al(刘秋江,陈朝阳,范艳伟,等). Nuclear Electronics & Detection Technology(核电子学与探测技术),2007,27(2):350. [7] Buhler P, Desorgher L, Zehnder A, et al. Radiation Measurements, 1996, 26: 917. [8] Bogorad A, Bowman C, Dennis A, et al. IEEE Transactions on Nnclear Science, 1995, 42: 2051. [9] MacKay G F, Thomson I, Ng A, et al. IEEE Transactions on Nuclear Science, 1997, 44: 2048. [10] Dusseau L, Polge G, Albert L, et al. IEEE Transactions on Nuclear Science, 1998, 45: 2695. [11] Gaza R, Mckeever S W S, Akselrad M S, et al. Radiation Measurements, 2004, 38: 809. [12] LIU Qiu-jiang, CHEN Chao-yang, FAN Yan-wei, et al(刘秋江,陈朝阳,范艳伟,等). Atomic Energy Science and Technology(原子能科学技术),2007,41(4):390. [13] Gaza R. A Fiber-optics, Real-time Dosimeter Based on Optically Stimulated Luminescence of Al<sub>2</sub>O<sub>3</sub>: C and KBr∶Eu for Potential Use in the Radiotherapy of Cancer. Cancer. United States, Oklahoma State University Press, 2004. 86. [14] XU Chang-tan, ZHOU Zhi-ming(许长谭,周志明). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2001,21(3):298. [15] Zheng W C, Zhou Q, Wu X X, et al. Spectrochim. Acta A, 2005, 61: 1243. [16] Pavotti F, Glaser M, Idri K et al. IEEE Transactions on Nuclear Science, 2005, 52: 1568. [17] Gasiot J, Braunlich P, Fillard J P. Applied Physics Letters, 1982, 40(5): 376. [18] Gander M J, Galliot E A C, McBride R, et al. Bend Measurement Using Mutli-Core Optical Fiber. 12th Internationl Conference on Optical Fiber Sensor, 1997. 166. [19] Santoro K, Charpiot L, Herault E, et al. IEEE Transactions on Nuclear Science, 2004, 51(6): 3638. [20] RVailleJ, Ducret S, Saigne K, et al. IEEE Transactions on Nuclear Science, 2003, 50(6): 2358. [21] MIAO Zhuang, LI Shan-feng, ZHANG Qing-yu(苗 壮, 李善锋, 张庆瑜). Acta Physica Sinica(物理学报), 2006, 55(8): 4321. [22] Gasiot J, Brunlich P, Fillard P J. Appl. Phys. Lett., 1982, 40: 376.