Comparative Study of Reflectance Spectroscopy of Human Laogong Acupoint and Non-Acupoint Tissues Irradiated by Near-Infrared Laser
ZHANG Zu-de1,GUO Zhou-yi1,WEI Hua-jiang1*,LIU Han-ping1,ZHONG Hui-qing1,YANG Hong-qin2,XIE Shu-sen2, LIU Song-hao1
1. Key Laboratory of Laser Life Science and Institute of Laser Life Science, Ministry of Education, South China Normal University, Guangzhou 510631, China 2. Key Laboratory of Optoelectronic Science and Technology for Medicine of Ministry of Education, Fujian Normal University, Fuzhou 350007, China
Abstract:Characteristics and differences of reflectance spectroscopy of human Laogong acupoint and non-acupoint tissues before and after irradiation by different power of laser were studied in the spectral range from 400 to 1 000 nm. A wavelength 808 nm semiconductor laser was used for irradiation at the power of 20, 50 and 100 mW for ten minutes. Reflectance spectra of human Laogong acupoint and non-acupoint tissues were measured by using an AvaSpec-2048 optical fiber spectroscopy with an integrating sphere attachment. The result shows that before irradiation the shape of the reflectance spectra of Laogong acupoint and non-acupoint is similar, they have the same troughs at 423, 544, 577 and 980 nm, and the reflectance for Laogong acupoint and non-acupoint at these wavelengths is 17.1%, 26.1%, 25.9% and 35.0%, and 17.1%, 27.6%, 28.1% and 36.5% respectively. But from 475 to 1 000 nm, the reflectance of Laogong acupoint is smaller than that of non-acupoint. After being irradiated by semiconductor laser at the power of 20, 50 and 100 mW, there is a very significant decrease in the reflectance of Laogong acupoint compared to that before irradiation, and the higher the power, the lower the reflectance. But there is just a small decrease in the reflectance for non-acupoint compared to that before irradiation. From the above results, it is clearly seen that Laogong acupoint is different from non-acupoint on reflectance spectroscopy, and Laogong acupoint is more sensitive to laser irradiation than non-acupoint tissue.
[1] LIN Wen-zhu(林文注). Shanghai Journal of Acupuncture and Moxibustion(上海针灸杂志), 1998, 17(4): 37. [2] FEI Lun, CHENG Huan-sheng, CAI De-heng, et al(费 伦, 承焕生,蔡德亨, 等). Chinese Science Bulletin(科学通报), 1998, 43(6):658. [3] YU An-sheng, ZHAO Ying-xia, YAN Zhen-guo(余安胜, 赵英侠, 严振国). Chinese Acupuncture and Moxibustion(中国针灸), 1999, 19(1): 27. [4] MIN You-jiang, YAO Hai-hua, YAN Zhen-guo(闵友江, 姚海华, 严振国). Journal of Liaoning University of Traditional Chinese Medicine(辽宁中医药大学学报), 2007, 9(4):27. [5] HAN Yin-hua, DING Guang-hong, SHEN Xue-yong, et al(韩吟华, 丁光宏, 沈雪勇, 等). Shanghai Journal of Biomedical Engineering(上海生物医学工程), 2005, 26(4): 198. [6] DING Guang-hong,YAO Wei, CHU Jun-hao, et al(丁光宏, 姚 伟, 褚君浩, 等). Chinese Science Bulletin(科学通报), 2000, 45(23): 2530. [7] Lo S Y. Meridians in Acupuncture and Infrared Imaging. Med. Hypoth., 2002, 58: 72. [8] LIU Han-ping, SHEN Xue-yong, DENG Hai-ping, et al(刘汉平, 沈雪勇, 邓海平, 等). Shanghai Journal of Traditional Chinese Medicine(上海中医药杂志), 2004, 38(4): 52. [9] YANG Hong-qin, XIE Shu-sen, HU Xiang-long, et al. Am. J. Chinese Medicine, 2007, 35(2): 231. [10] Yang Hongqin, Xie Shusen, Liu Songhao, et al. Am. J. Chinese Medicine, 2007, 35(5): 743. [11] LI Hui, YANG Hong-qin, XIE Shu-sen(李 晖,杨洪钦,谢树森). Science in China, G(中国科学·G辑), 2007, 37: 62. [12] Mester E. OrvHetil, 1966, 107(22): 1012. [13] LI Zhong-ming, ZHANG Zhen-xi(李忠明, 张镇西). Chinese Acta Laser Biology Sinica(激光生物学报),2006, 15 (3): 272. [14] Whttaker P. Lasers in Medical Science, 2004, 19(2): 69. [15] Niemz Markolf H. Laser-Tissue Interactions Fundamentals and Applications(激光与生物组织的相互作用原理及应用). Translated by ZHANG Zhen-xi(张振西,译). Beijing: Science Press(北京:科学出版社), 2005. [16] Urs Utzinger, Molly Brewer, Elvio Silva, et al. Lasers in Surgery and Medicine, 2001, 28: 56. [17] YANG Hong-qin, XIE Shu-sen, LI Hui, et al(杨洪钦,谢树森,李 晖,等). Chinese Optics Letters(中国光学快报), 2007, 5(3): 181. [18] WANG Xianju, ZENG Changchun, LIU Hanping, et al. Proc. SPIE, 2005, 6047: 604701-1.