Abstract:The flame temperature was measured by the double line of atomic emission spectroscopy according to the spectra of K (766.5 and 769.9 nm) whose relative intensity was obtained by fiber spectrometer. The principles, methods and experiment system were described. The temperature measured by the double line of atomic emission spectroscopy was compared to the results measured by thermal couple under the condition of thermal equilibrium of blackbody furnace. The comparison indicated a good coherence between these two measurement methods. The method was demonstrated on coal powder and timber, and the temperature measured corresponded to reality.
Key words:Flame temperature;Atomic emission spectroscopy;Combustion;Measurement of temperature
陈晓斌,蔡小舒,范学良,沈嘉琪. 原子发射双谱线法测火焰温度的实验研究[J]. 光谱学与光谱分析, 2009, 29(12): 3177-3180.