Abstract:Based on the repeatability and intermediate precision of time differences in the standard, through inspection of the data of repeatability and trueness of measurements within the time intervals, repeatability between time intervals, general precision between time intervals and trueness of grand mean of long-term stability test. The long-term stability of analytical instruments can be systematically evaluated according to the standard, the essence of which is to monitor the precision and accuracy of analysis results. However, a large number of test methods in the laboratory that have not been upgraded to standards, the so-called non-standard methods, cannot be directly evaluated for long-term stability according to the above methods due to the lack of repeatability and laboratory reproducibility data. Fortunately, the stimulated repeatability and within-laboratory reproducibility limits were obtained for non-standard test methods after correcting the instrument between different time intervals. Based on the stimulated repeatability limit and within-laboratory reproducibility limit, the long-term stability of the corresponding analytical instrument method can be evaluated. This paper uses the non-standard method for determining 18 impurity elements in pure nickel by glow discharge mass spectrometry (GD-MS) as an example. A set of comparative experiments are designed to obtain the simulation reproducibility limit and simulation reproducibility limit data. The long-term stability time for 18 impurity elements, such as B, Mg, Al and Si in pure nickel samples was evaluated by χ2 statistics after being tested by GD-MS. The results showed that the long-term stability was different for different elements when determined under the same condition. The results met the statistical requirements for most elements within 3 hours. Among these, the long-term stability interval can be up to 6 hours or even 12 hours for elements P, As, V, Sb and Pb. The reliable results can be obtained within that time interval without instrument correction. The evaluation results are consistent with the laboratory experience, indicating that the systematic measurement and characterization method proposed in this experiment objectively reflects the long-term stability of the GD-MS objectively. This method can also be used to evaluate the long-term stability of other non-standard methods, which has significant practical guidance for the quality control for the laboratory.
Key words:GD-MS; Non-standard test methods; Long-term stability; Trueness; Precision
杨国武,侯艳霞,孙晓飞,贾云海,李小佳. 非标方法长期稳定性评价及在辉光放电质谱分析纯镍中痕量元素的应用[J]. 光谱学与光谱分析, 2023, 43(03): 867-876.
YANG Guo-wu, HOU Yan-xia, SUN Xiao-fei, JIA Yun-hai, LI Xiao-jia. Evaluation of Long-Term Stability for Non-Standard Method and
Application in Trace Element Analysis of Pure Nickel by Glow
Discharge Mass Spectrometry. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 867-876.
[1] JIA Yun-hai, SUN Xiao-fei, YUAN Liang-jing(贾云海, 孙晓飞, 袁良经). Metallurgical Analysis(冶金分析), 2019, 39(1): 1.
[2] ISO 5725-2: 2019, Accuracy (Trueness and Precision) of Measurement Methods and Results-Part 2: Basic Method for the Determination of Repeatability and Reproducibility of a Standard Measurement Method. International Standard.
[3] ISO 5725-3: 1994, Accuracy (Trueness and Precision) of Measurement Methods and Results-Part 3: Intermediate Measures of the Precision of a Standard Measurement Method. International Standard.
[4] ASTM F1593-2008(2016), Standard Test Method for Trace Metallic Impurities in Electronic Grade Aluminum by High Mass-Resolution Glow-Discharge Mass Spectrometer. ASTM International.
[5] Hu F F, Wang C H, Li J D, et al. At. Spectrosc.,2021, 42(1): 25.
[6] Patricia Grinberg, Bradley A J Methven, Katarzyna Swider, et al. ACS Omega,2021, b(35): 22717.
[7] Yang Weifeng, Zhuo Shangjun, Zhu Zhenli, et al. J. Anal. At. Spectrom., 2021, 36:932.
[8] Gagan Paudel, Marisa Di Sabatino. J. Anal. At. Spectrom.,2020, 35: 2748.
[9] Lara Lobo, Beatriz Fernández, Marta Aranaz, et al. Spectrochimica Acta Part B,2020,168:105865.
[10] Paudel G, Kasik M,Di Sabatino M. J. Anal. At. Spectrom., 2019, 34: 1829.
[11] Cristina Gonzalez-Gago, Petr Smid, Thomas Hofmann, et al. J. Anal. At. Spectrom.,2019, 34: 1109.
[12] Wei Xinjian, Qin Zhen, Xiong Penghui, et al. Spectrochimica Acta Part B, 2019, 154: 43.
[13] WANG Zi-ren, WANG Chang-hua, HU Fang-fei, et al(王梓任,王长华,胡芳菲,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2019, 39(4): 1256.
[14] Anna Gubala, Alexander Ganeeva, Victoria Bodnara, et al. Vacuum,2018, 153: 248.
[15] Kentaro Yamada, Michihisa Uemoto. Analytical Sciences,2018, 34: 743.
[16] Fu Liang, Ma Juncai, Shi Shuyun. J. Cent. South Univ., 2018, 25: 1590.
[17] ZHANG Jian-ying, LI Xin-ni, ZHOU Tao, et al(张见营, 李昕霓,周 涛, 等). Chin. J. Anal. Chem.(分析化学), 2018, 46(5): 757.
[18] Juris Meija, Brad Methven, Ralph E Sturgeon. Metrologia,2017, 54: 796.
[19] Wei Juan, Dong Jiangli, Zhuo Shangjun, et al. Anal. Chem.,2017, 89, 1382.
[20] Zhang Jianying, Zhou Tao, Tang Yichuan, et al. J. Anal. At. Spectrom., 2016, 31: 2182.
[21] WEI Xing-jian, WANG Li-ping, QIN Zhen, et al(魏兴俭, 王丽萍, 秦 震,等). J. Chin. Mass Spectrom. Soc.(质谱学报), 2016, 37(4): 343.
[22] LIU Hong-wei, FU Liang, SUN Ai-ming, et al(刘宏伟, 符 靓, 孙爱明, 等). Chin. J. Anal. Chem.(分析化学), 2015, 43(9): 1366.
[23] Marisa Di Sabatino, Anne L. Dons, Joachim Hinrichs, et al. Spectrochimica Acta Part B,2011, 66: 144.
[24] QIAN Rong,ZHUO Shang-jun, DONG Jiang-li, et al(钱 荣,卓尚军,董疆丽,等). Theory and Application of Glow Discharge Mass Spectrometry(辉光放电质谱理论与应用). Shanghai: Shanghai Science and Technology Press(上海: 上海科学技术出版社),2017.
[25] Jurgen H Gross. Mass Spectrometry (2nd Edition)(质谱,第2版). Beijing:Science Press(北京:科学出版社),2014. 1, 694.