Abstract:In the background of high counting rate, the full-energy peak of X-rays fluorescence is seriously disturbed by the false peak whichis caused by the charge sensitive preamplifier in High Performance Silicon Drift Detector and slow digital shaping algorithm. In this paper, a novel method of false peak eliminating is presented. And some technical points are also introduced in details such asdigital triangleshaping, signal screening and peak discrimination. Taking 55Fe nuclide and rock samples as experimentations, the spectrum before and after the false peak eliminating are compared. And the results showed that the false peak can availably be eliminated. Therefore, the performance of fine X-rays fluorescence will be improved such as peak to background ratio and accuracy of trace elements analysing.
Key words:Fine EDXRF; High performance silicon drift detector; False peak eliminating; Signal screening
周 伟,刘泽威,周 航,梁菲惜,张蓉舟. 精细X荧光光谱中伪峰剔除方法的研究[J]. 光谱学与光谱分析, 2018, 38(11): 3593-3597.
ZHOU Wei, LIU Ze-wei, ZHOU Hang, LIANG Fei-xi, ZHANG Rong-zhou. Study of the False Peak Eliminating Algorithm in Fine EDXRF. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(11): 3593-3597.
[1] Application Note AN-SDD-003: Amptek Silicon Drift Detectors.
[2] http://amptek.com/products/fast-sdd-silicon-drift-detector.
[3] Mott R B. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2010, 624(2): 265.
[4] Menaa N, D’Agostino P, Jordanov V T, et al. Nuclear Instruments & Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2011, 652(1): 512.
[5] Sharanabasappa,B Kerur R,Anilkumar S, et al. Applied Radiation and Isotopes,2010, 68(1): 76.
[6] Alberto Regadío, Sebastián Sánchez-Prieto, Manuel Prieto. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014, 735(1): 297.
[7] Syntfeld-Kauch A, Sibczyński P, Moszyński M, et al. Radiation Measurements,2010, 45(3-6): 377.
[8] Nakhostin M, Hitomi K, Ishii K, et al. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2010, 615(2): 242.
[9] Noulis T, Deradonis C, Siskos S. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2008, 589(2): 330.
[10] Hansen K, Reckleben C, Diehl I, et al. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2008, 589(2): 250.
[11] Valentin T Jordanov, Glenn F Knoll. Nuclear Instruments and Methods in Physics Research A, 1994,345:337.
[12] Valentin T Jordanov, Glenn F Knoll, Alan C Huber, et al. Nuclear Instruments and Methods in Physics Research A, 1994,353:261.
[13] ZHOU Wei, YU Jie, ZHOU Jian-bin, et al(周 伟,喻 杰,周建斌,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2017, 37(7): 2242.