Study on the Laser-Induced Plasma Spectroscopy Based on the Echelle Spectrometer |
ZHANG Rui1,2, ZHU Ji-wei1, LIU Jian-li1,2, CUI Ji-cheng1, LI Xiao-tian1, Bayanheshig1 |
1. Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
2. University of Chinese Academy of Sciences, Beijing 100049, China |
|
|
Abstract In order to meet the requirements of laser induced plasma analysis system (LIPS), the spectral resolution, spectral range and volume of the optical system. In this paper, the echelle spectrograph is developed. The spectrometer can simultaneously obtain spectral information in all spectral segments, which enables the LIPS system to perform fast, online and real-time analysis. Also, the spectrometer uses an adjustable delay time ICCD as the back end detector. The system can select the optimal delay time to receive the spectrum and improve the signal-to-noise ratio of the whole system. Finally, a set of laser induced plasma analysis system is built to verify the applicability of the echelle spectrometer in the system. By testing the alloy sample, the resolution of the whole system is 0.02 nm, and the spectrum range is 190~600 nm. Moreover, the LIPS system has good spectral reproducibility, and the extraction error of the characteristic element wavelength is no more than 0.01 nm, which can be used to analyze the composition of the sample accurately.
|
Received: 2017-05-24
Accepted: 2017-10-19
|
|
|
[1] Fu Yangting, Hou Zongyu, Wang Zhe. Optics Express, 2016, 24(3): 3055.
[2] Harilal S S, Yeak J, Phillips M C. Optics Express, 2015, 23(21): 27113.
[3] Eric Jobiliong, Hery Suyanto, Alion Mangasi Marpaung, et al. Applied Spectroscopy, 2015, 69(1): 115.
[4] Melikechia N, Mezzacappa A, Cousinb A, et al. Spectrochimica Acta Part B, 2014, 96: 51.
[5] Gondal M A, Maganda Y W, Dastageer M A, et al. Applied Optics, 2014, 53(8): 1636.
[6] Unnikrishnan V K, Rajesh Nayak, Dastageer M A, et al. AIP Advances, 2014, 4(9): 097104.
[7] Arel Weisberg, Rollin E Lakis, Michael F Simpson, et al. Applied Spectroscopy,2014,68(9): 937.
[8] Zahra Derakhshan Zadeh, Seyyed Jabbar Mousavi. Optics in the Life Sciences,2017,JTu4A: 19.
[9] Sedeep Jung Pandey, Mauro Martinez, Jan Hostasa, et al. Optical Materials Express, 2017, 7(5): 285770.
[10] Chet R Bhatt, Fang Y Yueh, Jagdish P Singh. Applied Optics,2017,56(8): 2280.
[11] JIAN Rong-hua, WU Ping-hui, HUANG Wen-hua(简荣华,吴平辉,黄文华). Acta Photonica Sinica(光子学报), 2015, 44(2): 0222003.
[12] QI Hong-xing, CHEN Mu-wang, Lü Gang(亓洪兴,陈木旺,吕 刚). Laser Journal(激光杂志), 2006, 27(4): 29.
[13] Daniel Riebe, Toralf Beitz, Carsten Dosche. Applied Spectroscopy, 2014, 68(9): 1030.
[14] Igor B Gornushkin, Ben W Smith, Ulrich Panne, Nicolo′ Omenettob. Applied Spectroscopy,2014,68(9): 1076.
[15] Patrick D Barnett, Nirmal Lamsal, S Michael Angel. Applied Spectroscopy,2017,71(4): 583. |
[1] |
HAO Li-hua1,2, LU Xiao-dong2, WANG Ming-quan1,2. Research on a Novel Static Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(09): 2971-2975. |
[2] |
HU Wen-bin1, MA Zhi-min1*, TIAN Meng1, ZHAO Xiao-hong1, HU Xiang-yang2. Multispectral-Based Particle Image Velocimetry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2038-2043. |
[3] |
LIU Xiang-lei1,2, LIU Yang-yang1*, FANG Yu1, PEI Lin-lin1, Lü Qun-bo1. Optical Design of Large Relief Large Relative Apertureand High Resolution Modified Dyson Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3908-3912. |
[4] |
SUN Jian-zhong1,2, ZHANG Le2*, GAO Fei1, LI Jiu-sheng1. Quality Improvement and Noise Reduction of Terahertz Continuous Wave Imaging[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(11): 3343-3346. |
[5] |
LEI Fan-pu1, 2, 3, BAI Yong-lin3, ZHU Bing-li3, BAI Xiao-hong3, QIN Jun-jun3, XU Peng3, HOU Xun1. Study of Ultraviolet Photon Counting Detector with Delay-Line Anode[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 2989-2994. |
[6] |
LI Su-yi1,XU Zhuang1,XIONG Wen-ji2,JIANG Shan-qing1,WU Jiang1*. An Automatic Peak Identification Method for Photoplethysmography Signals[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3145-3149. |
[7] |
LIU Lu1,2,3, CHEN Yuan-yuan1,2,3*, ZHANG Rui1,2,3, WANG Zhi-bin1,2,3, XUE Peng1,3, LI Xiang2. Study on 0 Level Interference Suppression Method for Hyperspectral Imaging Based on AOTF[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3182-3186. |
[8] |
SHEN Chun-yang1, 2, CUI Ji-cheng1*, SUN Ci1, WANG Wei1, 2, CHEN Jian-jun1, 2, LI Xiao-tian1. A Detection System Design of Echelle Diffraction Efficiency and Stray Coefficient[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2603-2609. |
[9] |
ZHENG Zhi-zhong1,2, YANG Zhong1*, XIU Lian-cun2, DONG Jin-xin2, CHEN Chun-xia2, GAO Yang2, YU Zheng-kui2. Design of a SWIR Offner Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2267-2272. |
[10] |
ZHANG Hai-wei1,2, WANG Lei1,2*, LENG Feng-qing1,2*, TUO Xian-guo3, LIU Ming-zhe1,2, CHENG Yi2, YAO Fu-liang2, LI San-gang2, ZHAO Bai-jun2, LU Wei2. Properties and Application Studies of LaBr3(Ce) Scintillation Detector[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2298-2304. |
[11] |
SUN Shou-qiang, GU Mu*, CHEN Ting-ting, ZHANG Juan-nan, LIU Xiao-lin, LIU Bo, HUANG Shi-ming, NI Chen. Fabrication and Performance of Pixelated γ-CuI Scintillation Conversion Screens Based on Oxidized Silicon Micropore Arrays[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(05): 1566-1570. |
[12] |
HUANG Yuan-shen1, 2, DONG Cheng-cheng1, 2*, HUANG Yun-bai1, 2, SHENG Bin1, 2, ZHOU Hong-yan1, 2, SUN Le1, 2, YANG Hai-ma1, 2, ZHANG Da-wei1, 2 . Research on Straightness Error Compensation of Grating Ruling Machine [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(03): 946-951. |
[13] |
ZHENG Lian-hui1,2,3,4, RAO Chang-hui1,2*, GU Nai-ting1,2, QIU Qi4 . The Aberration Corrected Grating Spectrometer Based on Adaptive Optics [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4088-4093. |
[14] |
LU Min1, LI Xiao-xia1,2*, SHANG Li-ping2, DENG Hu1,2 . Research on the Method of Improving Terahertz Frequency Resolution Based on Empirical Mode Decomposition [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(09): 2732-2735. |
[15] |
LI Zhi-wei1, 2, 3, XIONG Wei1, 3*, SHI Hai-liang1, 3, LUO Hai-yan1, 3, QIAO Yan-li1, 3 . Study on Asymmetric Spatial Heterodyne Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2291-2295. |
|
|
|
|