光谱学与光谱分析 |
|
|
|
|
|
The Analysis of Microcavity-Integrated Graphene Photodetector’s SNR Based on 1.06 μm |
LIANG Zhen-jiang, LIU Hai-xia*, LIU Kai-ming, NIU Yan-xiong, YIN Yi-heng |
School of Instrument Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China |
|
|
Abstract Avalanche photodiode is widely used in laser rangefinder due to high gain characteristics, but introduces highly additive noise during the time of current’s multiplication that makes laser rangefinder’s SNR meet bottleneck. This paper proposes a method of designing a high SNR’s graphene photodetector based on microcavity. The graphene’s unique optoelectronic properties make it an ideal platform for a variety of photonic applications, such as fast lasers, optical modulators, transparent electrodes, and ultrafast photodetectors. It has been recognized internationally to have dominant advantages in photodetectors due to its high carrier mobility, gapless spectrum, and frequency-independent absorption coefficient. With the wavelength of 1.06 μm, the mechanism of light waves’ transmission in the cavity and the graphehne’s absorption are studied by using optical transmission matrix method and scattering matrix method; the light absorption model of the graphene photodetector based on microcavity is established. Device’s final quantum efficiency reaches 91.2%, respectively reaches 0.778 A·W-1, its full width at half maximum (FWHM) reaches 6 nm; the influence between graphene’s position in the microcavity and device’s absorption shows that device’s absorption’s peak value changes periodically with graphene’s position under resonant condition, and the variety of length of microcavity does not have any influence on the peak value, but changes the graphene’s position when absorption reaches peak value, on the condition that the length of microcavity is n times of half of wavelength, the number of device’s absorption peak value is 2n with the variety of graphene’s position, and all the peak values are symmetrical with respect to the center of microcavity, the final graphene’s position is 0.402 8 mm away from the top mirror of microcavity, and the absorption reaches 94%, Compared with single layer graphene, the absorption rate increases 16 dB; By solving SNR equation of the graphene photodetector based on microcavity and SNR equation of the avalanche photodiode, eventually finds that the SNR of the graphene photodetector based on microcavity is 90.3, which raises 10 dB compared with the avalanche photodiode’s. Theoretical analysis shows the graphene photodetector based on microcavity has high absorption rate, high quantum efficiency, and high SNR. In this paper, the research achievements provide a theoretical reference to update and design higher SNR photodetector used in laser rangefinder’s receiving system.
|
Received: 2016-03-23
Accepted: 2016-08-04
|
|
Corresponding Authors:
LIU Hai-xia
E-mail: liuhx08@buaa.edu.cn
|
|
[1] Yin W H, Han Q, Yang X H. Acta Phys. Sin., 2012, 61: 248502. [2] Zhang Q H, Han J H, Feng G Y, et al. Acta Phys. Sin.,2012,61:214209. [3] Chen Y L, Feng X B, Hou D D. Acta Phys. Sin., 2013, 62: 187301. [4] Zhao J H, Song L Y, Ji R B. Infrared Technology, 2014, 36: 609. [5] Zeng C, Guo J, Liu X M. Applied Physics Letters, 2014, 105: 121103. [6] Engel M, Steiner M, Lombardo A. Nat. Commun., 2012, 3: 906. [7] Furchi M, Urich A, Pospischil A. Nano Lett., 2012, 12(6): 2773. [8] Gao L B, Ren W C, Xu H L. Nat. Commun., 2012, 3699. [9] Li S J, Gan S, Mu H R. New Carbon Materials, 2014, 29: 329. [10] Ferreira A, Peres N M R. Phys. Rev., 2012, B85: 115438. |
[1] |
LIU Yuan-yuan1, CHEN Jian-jun2, QIU Bo1*, FAN Xiao-dong1, WEI Shi-ya1, SONG Tao1, DUAN Fu-qing3*. A Processing Method for Low SNR Repetitive Observation Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2311-2314. |
[2] |
ZHANG Yu-feng1, LI Ming1, DAI Jing-min2, SHAO Zhu-feng1, WU Yuan-qing1. Measuring Method of the Spectral Absorptivity for Solar Selective Absorption Coatings at High Temperature[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(06): 1814-1818. |
[3] |
LI Xiao-nan1, LIU Guo-qiang1, 2, HU Li-li1. Research on Nuclear Magnetic Resonance High-Quality Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(05): 1358-1361. |
[4] |
WANG Xin*, HE Hao, FAN Xian-guang, TANG Ming. Signal Processing Method for Raman Spectra Based on Matching Pursuit[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(01): 93-98. |
[5] |
SUN Jian-zhong1,2, ZHANG Le2*, GAO Fei1, LI Jiu-sheng1. Quality Improvement and Noise Reduction of Terahertz Continuous Wave Imaging[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(11): 3343-3346. |
[6] |
RAO Zhi-min, HUA Deng-xin, HE Ting-yao*, WANG Qiang, LE Jing. Performance Analysis of Double Wavelength Fluorescence Lidar in Detecting Atmospheric Biological Aerosols[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2804-2808. |
[7] |
WANG Huan1,2, WANG Yong-zhi1, ZHAO Yu1, ZHU Li1, YIN Li-hui1*. Latest Methods of Fluorescence Suppression in Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2050-2056. |
[8] |
WANG Yu-tian, YANG Zhe, HOU Pei-guo*, CHENG Peng-fei, CAO Li-fang . Research on Spectroscopy Spectrum De-Noising of Mineral Oil Based on Lifting Scheme Wavelet Transform [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2144-2147. |
[9] |
Lü Jin-guang1, LIANG Jing-qiu1, LIANG Zhong-zhu1*, TIAN Chao1, 2, QIN Yu-xin1. Analysis and Design of Interference Imaging System in Fourier Transform Imaging Spectrometer Based on Multi-Micro-Mirror[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1554-1559. |
[10] |
Lü Xiao-jing, LI Ning*, WENG Chun-sheng . The Diagnostics of Detonation Flow External Field Based on Multispectral Absorption Spectroscopy Technology [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 624-630. |
[11] |
TANG Jun1,2, LEI Long-hai1,2, ZHANG Wei1,2, ZHANG Tian-en1,2, XUE Chen-yang1,2, ZHANG Wen-dong1,2, LIU Jun1,2*. Study on Strain Detection with Si Based on Bicyclic Cascade Optical Microring Resonator[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 874-879. |
[12] |
LI Wen-chao2, MENG Xiao-yun1, PIAO Rui-qi1, ZHAO Jing-jing1, LI Zhi-quan1*, TONG Kai1, GU Er-dan1 . Brand-New Ge20Ga5Sb10S65 Prism Biosensor Based on Inverted SPR [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(02): 571-576. |
[13] |
XING Li-yun1, 2, CUI Hong-liang1, 3*, SHI Chang-cheng3*, HAN Xiao-hui1, ZHANG Zi-yin1, LI Wei3, MA Yu-ting1, 3, ZHENG Yan1*, ZHANG Song-nian4 . Experimental Study of PMI Foam Composite Properties in Terahertz [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(12): 3319-3324. |
[14] |
LIU Hui-jun1,2, TAO Shao-hua1,2*, YANG Bing-chu1, DENG Hong-gui1 . Gas Concentration Measurement Based on the Integral Value of Absorptance Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(12): 3490-3494. |
[15] |
ZOU Sheng1, ZHANG Hong1, CHEN Yao2, CHEN Xi-yuan1* . Measurement of Mole Ratio for Alkali Metal Mixture by Using Spectral Absorption Method [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(08): 2281-2286. |
|
|
|
|