光谱学与光谱分析 |
|
|
|
|
|
The Analysis of Microcavity-Integrated Graphene Photodetector’s SNR Based on 1.06 μm |
LIANG Zhen-jiang, LIU Hai-xia*, LIU Kai-ming, NIU Yan-xiong, YIN Yi-heng |
School of Instrument Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China |
|
|
Abstract Avalanche photodiode is widely used in laser rangefinder due to high gain characteristics, but introduces highly additive noise during the time of current’s multiplication that makes laser rangefinder’s SNR meet bottleneck. This paper proposes a method of designing a high SNR’s graphene photodetector based on microcavity. The graphene’s unique optoelectronic properties make it an ideal platform for a variety of photonic applications, such as fast lasers, optical modulators, transparent electrodes, and ultrafast photodetectors. It has been recognized internationally to have dominant advantages in photodetectors due to its high carrier mobility, gapless spectrum, and frequency-independent absorption coefficient. With the wavelength of 1.06 μm, the mechanism of light waves’ transmission in the cavity and the graphehne’s absorption are studied by using optical transmission matrix method and scattering matrix method; the light absorption model of the graphene photodetector based on microcavity is established. Device’s final quantum efficiency reaches 91.2%, respectively reaches 0.778 A·W-1, its full width at half maximum (FWHM) reaches 6 nm; the influence between graphene’s position in the microcavity and device’s absorption shows that device’s absorption’s peak value changes periodically with graphene’s position under resonant condition, and the variety of length of microcavity does not have any influence on the peak value, but changes the graphene’s position when absorption reaches peak value, on the condition that the length of microcavity is n times of half of wavelength, the number of device’s absorption peak value is 2n with the variety of graphene’s position, and all the peak values are symmetrical with respect to the center of microcavity, the final graphene’s position is 0.402 8 mm away from the top mirror of microcavity, and the absorption reaches 94%, Compared with single layer graphene, the absorption rate increases 16 dB; By solving SNR equation of the graphene photodetector based on microcavity and SNR equation of the avalanche photodiode, eventually finds that the SNR of the graphene photodetector based on microcavity is 90.3, which raises 10 dB compared with the avalanche photodiode’s. Theoretical analysis shows the graphene photodetector based on microcavity has high absorption rate, high quantum efficiency, and high SNR. In this paper, the research achievements provide a theoretical reference to update and design higher SNR photodetector used in laser rangefinder’s receiving system.
|
Received: 2016-03-23
Accepted: 2016-08-04
|
|
Corresponding Authors:
LIU Hai-xia
E-mail: liuhx08@buaa.edu.cn
|
|
[1] Yin W H, Han Q, Yang X H. Acta Phys. Sin., 2012, 61: 248502. [2] Zhang Q H, Han J H, Feng G Y, et al. Acta Phys. Sin.,2012,61:214209. [3] Chen Y L, Feng X B, Hou D D. Acta Phys. Sin., 2013, 62: 187301. [4] Zhao J H, Song L Y, Ji R B. Infrared Technology, 2014, 36: 609. [5] Zeng C, Guo J, Liu X M. Applied Physics Letters, 2014, 105: 121103. [6] Engel M, Steiner M, Lombardo A. Nat. Commun., 2012, 3: 906. [7] Furchi M, Urich A, Pospischil A. Nano Lett., 2012, 12(6): 2773. [8] Gao L B, Ren W C, Xu H L. Nat. Commun., 2012, 3699. [9] Li S J, Gan S, Mu H R. New Carbon Materials, 2014, 29: 329. [10] Ferreira A, Peres N M R. Phys. Rev., 2012, B85: 115438. |
[1] |
TIAN Si-di1, WANG Zhen1, DU Yan-jun2, DING Yan-jun1, PENG Zhi-min1*. High Precision Measurement of Spectroscopic Parameters of CO at 2.3 μm Based on Wavelength Modulation-Direct Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(07): 2246-2251. |
[2] |
GUAN Jian-fei, CHEN Tao. High Sensitivity Nanosensor Based on Fano Resonance in a
Metal-Dielectric-Metal Waveguide Coupled With a
Split-Ring Cavity[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1746-1751. |
[3] |
PAN Ke-yu1, 2, ZHU Ming-yao1, 2, WANG Yi-meng1, 2, XU Yang1, CHI Ming-bo1, 2*, WU Yi-hui1, 2*. Research on the Influence of Modulation Depth of Phase Sensitive
Detection on Stimulated Raman Signal Intensity and
Signal-to-Noise Ratio[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1068-1074. |
[4] |
LIU Ye-kun, HAO Xiao-jian*, YANG Yan-wei, HAO Wen-yuan, SUN Peng, PAN Bao-wu. Quantitative Analysis of Soil Heavy Metal Elements Based on Cavity
Confinement LIBS Combined With Machine Learning[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(08): 2387-2391. |
[5] |
WANG Yue1, 3, 4, CHEN Nan1, 2, 3, 4, WANG Bo-yu1, 5, LIU Tao1, 3, 4*, XIA Yang1, 2, 3, 4*. Fourier Transform Near-Infrared Spectral System Based on Laser-Driven Plasma Light Source[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(06): 1666-1673. |
[6] |
YANG Yu-qing1, CAI Jiang-hui1, 2*, YANG Hai-feng1*, ZHAO Xu-jun1, YIN Xiao-na1. LAMOST Unknown Spectral Analysis Based on Influence Space and Data Field[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1186-1191. |
[7] |
HU Li-hong1, ZHANG Jin-tong1, WANG Li-yun2, ZHOU Gang3, WANG Jiang-yong1*, XU Cong-kang1*. Optimization of Working Parameters of Glow Discharge Optical Emission Spectrometry of High Barrier Aluminum Plastic Film[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(03): 954-960. |
[8] |
LIU Hong-bo, SHI Xue-shun, ZHUANG Xin-gang, ZHANG Peng-ju, LIU Chang-ming, WANG Heng-fei. Simulation and Experimental Measurement of Cryogenic Radiometer Cavity With Different Structures[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 654-659. |
[9] |
CUI Fang-xiao1, ZHAO Yue2, MA Feng-xiang2, WU Jun1*, WANG An-jing1, LI Da-cheng1, LI Yang-yu1. Optimization of FTIR Passive Remote Sensing Signal-to-Noise Ratio and Its Application in SF6 Leak Detection in Transform Substation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1436-1440. |
[10] |
WANG Jing-jing1, 2, TAN Tu1*, WANG Gui-shi1, ZHU Gong-dong1, XUE Zheng-yue1, 2, LI Jun1, 2, LIU Xiao-hai1, 2, GAO Xiao-ming1, 2. Research on All-Fiber Dual-Channel Atmospheric Greenhouse Gases Laser Heterodyne Detection Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(02): 354-359. |
[11] |
SUN Ran, HAO Xiao-jian*, YANG Yan-wei, REN Long. Effect of Cavity Confinement Materials on Laser-Induced Breakdown Cu Plasma Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3801-3805. |
[12] |
ZHANG Yu-feng1, WANG Yang1, WU Yuan-qing1, DAI Jing-min2. Study on Metal Grating Structure for Improving Spectral Absorptivity of Infrared Microbolometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(08): 2647-2650. |
[13] |
SONG Shao-man1, 2, YAN Chang-xiang1, 3*. Trace Methane Detection Based on Cavity Ring-Down Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(07): 2023-2028. |
[14] |
ZHENG Guo-liang, ZHU Hong-qiu*, LI Yong-gang. Spectral Signal Denoising Algorithm Based on Improved LMS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(02): 643-649. |
[15] |
LI Zhi-wei1, 2, SHI Hai-liang1, 2, LUO Hai-yan1, 2, XIONG Wei1, 2*. Study on the Relationship Between Apodization Function and Signal-to-Noise Ratio of Hyperspectral Spatial Interferogram[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(01): 29-33. |
|
|
|
|