光谱学与光谱分析 |
|
|
|
|
|
Label-Free and Rapid Detection of Histidine-Rich Peptides in Saliva |
XIAO Sai-jin1, ZUO Jun1, DONG Xiao-feng2, ZHAO Xiao-jing1, ZHANG Li3* |
1. East China Institute of Technology, Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, Nanchang 330013, China 2. School of Mechanical and Electronic Engineering, East China Institute of Technology, Nanchang 330013, China 3. School of Chemistry, Nanching University, Nanchang 330033, China |
|
|
Abstract Siliva as a kind of biomarker containing a variety of bioactive components can be used to help disease diagnosis. Compared with the urine and blood, the collection of saliva is more simple and convenient while the collection process is completely non-invasive. Therefore, saliva detection attracts more and more attention in non-invasive disease diagnosis. Histatins are a family of small, cationic, histidine-rich peptides, which secreted by salivary bringing innate defense of the oral cavity. It has been reported that histatins are related to many other diseases, such as HIV and AIDs. Thus the detection of histatins in saliva is significantly important for oral healthy monitoring and disease diagnosis. In this paper, a new label free method for rapid detection of histidine-rich peptides was developed based on the fact that histidine-rich peptides can interact with 3-azidocoumarin through hydrogen bonds which decreases the electron-donating ability of the azido group and results in fluorescence enhancement of the system. The results showed that the fluorescence intensities were dramatically increased when histatin 5 were incubation with 3-azidocoumarin. There is a good relationship with the linear co r of 0.994 between the enhanced fluorescence and histatin 5 concentration ranging from 0.23 to 31.05 μmol·L-1, and the limit of detection is 72 nmol·L-1 (3σ/k). Moreover, the detection of histidine-rich peptides in saliva was successfully achieved by the new developed label free method since amino acids and proteins in saliva will not be interfered with the detection with the recoveries between 96.7%~111.6%. Compared with the existing saliva analysis methods, this method has the advantage of simple, fast and low cost. It might be applied in non-invasive disease diagnosis.
|
Received: 2015-03-24
Accepted: 2015-07-22
|
|
Corresponding Authors:
ZHANG Li
E-mail: zhangli8@ncu.edu.cn
|
|
[1] Thomadaki K, Helmerhorst E J, Tian N, et al. J. Dent. Res., 2011, 90: 1325. [2] Davidopoulou S, Theodoridis H, Nazer K, et al. J. Oral. Microbiol., 2014, 6: 26156. [3] Ramseier C A, Kinney J S, Herr A E, et al. J. Periodontol., 2009, 80: 436. [4] Blicharz T M, Siqueira W L, Helmerhorst E J, et al. Anal. Chem., 2009, 81: 2106. [5] Liu C, Geva E, Mauk M, et al. Analyst, 2011, 136: 2069. [6] Zhang L, Farrell J J, Zhou H, et al. Gastroenterology, 2010, 138: 949. [7] Floriano P N, Christodoulides N, Miller C S, et al. Clin. Chem., 2009 55: 1530. [8] MIAO Yan, HAO Yu-qing(苗 燕,郝玉庆) Int. J. Stomatol.(国际口腔医学杂志), 2007, 34: 271. [9] Sun X, Salih E, Oppenheim F G, et al. FASEB J., 2009, 23: 2691. [10] Borgwardt D S, Martin A D, Van Hemert J R, et al. Sci. Rep., 2014, 4: 3904. [11] Oppenheim F G, Helmerhorst E J, Lendenmann U, et al. PLos One, 2012, 7: e51479. [12] Thomadaki K, Bosch J A, Oppenheim F G, et al. J. Oral. Dis., 2013, 19: 781. [13] Khan S A, Jr P L F, Thunayyan A A, et al. J. AIDS Clin. Res., 2013, 4: 1000193. [14] Peters B M, Zhu J, Jr P L F, et al. FEMS Yeast Res., 2010, 10: 597. [15] Qiu S, Miao M, Wang T, et al. Biosens. Bioelectron., 2013, 42: 332. [16] Sivakumar K, Xie F, Cash B M, et al. Org. Lett., 2004, 6: 4603. [17] Thomadaki K, Helmerhorst E J, Tian N, et al. J. Dent. Res., 2011, 90: 1325. [18] Qiu S, Lin Z, Zhou Y, et al. Anal. Chem., 2013, 85: 11041. [19] Campese M, Sun X, Bosch J A, et al. J. Arch. Oral. Biol., 2009, 54: 345. |
[1] |
ZHAO Yu1, WEN Bao-ying1, HUANG Yi-wei1, ZHANG Hua1, Lü Jia-ni2*, LI Jian-feng1,3*. Rapid and Quantitative Detection of Pioglitazone Hydrochloride in Human Saliva by Portable Raman Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(12): 3769-3772. |
[2] |
LIN Xue-liang1, LIN Duo1, 2, QIU Su-fang3, GE Xiao-song1, PAN Jian-ji3, WU Qiong1, LIN Hui-jing1, HUANG Hao2*. Detection of Nasopharyngeal Carcinoma Based on Human Saliva Surface-Enhanced Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(08): 2430-2434. |
[3] |
LI Xiao-zhou1, 2, YANG Tian-yue1, DING Jian-hua2 . Surface Enhanced Raman Spectroscopy (SERS) of Saliva for the Diagnosis of Lung Cancer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(02): 391-393. |
|
|
|
|