光谱学与光谱分析 |
|
|
|
|
|
Simultaneous Determination of Sn and S in Methyltin Mercaptide by Microwave-Assisted Acid Digestion and ICP-OES |
CHEN Qian1, WU Xi2, HOU Xian-deng2, XU Kai-lai1* |
1. College of Chemistry, Sichuan University, Chengdu 610064, China 2. Analytical & Testing Centre, Sichuan University, Chengdu 610064, China |
|
|
Abstract Methyltin mercaptide is widely used as one of the best heat stabilizer in the polyvinylchloride (PVC) thermal processing due to its excellent stability, good transparency, high compatibility and weather resistance. The content of sulfur and tin significantly affects its quality and performance, so it is of great significance to develop an analytical method for the simultaneous determination of sulfur and tin. Inductively coupled plasma atomic emission spectrometry (ICP-OES) has been a powerful analytical tool for a myriad of complex samples owing to its advantages of the low detection limits, rapid and precise determinations over wide dynamic ranges, freedom from chemical inter-element interferences, the high sample throughput and above all, simultaneous multi-elements analysis. Microwave technique as a well-developed method for sample preparation can dramatically reduce the digestion time and the loss of volatile elements compared with the traditional open digestion. Hereby, a microwave-assisted acid digestion (MW-AAD) procedure followed by inductively coupled plasma optical emission spectroscopy (ICP-OES) analysis was developed for the simultaneous determination of Sn and S in methyltin mercaptide. This method has the advantages of simplicity, rapidness, good accuracy, green and less use of samples. Parameters affecting the MW-AAD such as the digestion solution and digestion time were optimized by using a chemical analyzed reference sample (DX-181) to attain tin and sulfur quantitative recoveries. HNO3-HCl-HClO4 (v/v/v=9∶3∶1) and 10 min were the optimum digestion solution and digestion time, respectively. Under optimum conditions, the standard addition method and the standard calibration curve method were both been used to detect Sn and S in DX-181. There was no significant difference between two methods and the relative deviations to the chemical analysis values were both less than 2%. Additionally, the accuracy of the MW-AAD method was examined by analyzing three methyltin mercaptide samples (DX-181,DX-990,DX-960). The results were satisfactory with the relative deviations (<3%) and the recoveries of standard addition (99%~102%).
|
Received: 2015-01-27
Accepted: 2015-04-16
|
|
Corresponding Authors:
XU Kai-lai
E-mail: xukailai@scu.edu.cn
|
|
[1] GB/T26026—2010. Methyltin Mercaptide(硫醇甲基锡). Inspection and Quarantine of the People’s Republic of China(中华人民共和国国家标准). [2] Thangavel S, Dash K, Dhavile S M et al. Talanta, 2015, 131: 505. [3] Villanueva-Alonso J, Pena-Vazquez E, Barciela-Alonso M C, et al. Atomic Spectroscopy, 2014, 35(1): 7. [4] Mketo N, Nomngongo P N, Ngila J C. Analytical Methods, 2014, 6(21): 8505. [5] Santelli R E, Oliveira E P, de Carvalho M d F B,et al. Spectrochimica Acta Part B: Atomic Spectroscopy, 2008, 63(7): 800. [6] Grindlay G, Maestre S, Gras L,et al. Journal of Analytical Atomic Spectrometry, 2006, 21(12): 1403. [7] Galbács G, Szorcsik A, Galbács Z,et al. Talanta, 2000, 52(6): 1061. [8] Burger K, Nagy L, Buzás N,et al. Journal of the Chemical Society, Dalton Transactions, 1993, 16: 2499. [9] Sánchez R, Todolí J L, Lienemann C P,et al. Spectrochimica Acta Part B: Atomic Spectroscopy, 2013, 88: 104. [10] Abu-Samra A, Morris J S, Koirtyohann S. Analytical Chemistry, 1975, 47(8): 1475. [11] ZHANG Liu-yi, FU Chuan, YANG Fu-mo,et al (张六一,付 川,杨复沫,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2014, 34(11): 3109. [12] Chand V, Prasad S. Microchemical Journal, 2013, 111: 53. [13] Sun Y C, Chi P H, Shiue M Y. Analytical Sciences, 2001, 17(12): 1395. [14] Kalembkiewicz J, Sitarz-Palczak E. Atomic Spectroscopy, 2001, 22(6): 433. |
[1] |
ZHU Hua-dong1, 2, 3, ZHANG Si-qi1, 2, 3, TANG Chun-jie1, 2, 3. Research and Application of On-Line Analysis of CO2 and H2S in Natural Gas Feed Gas by Laser Raman Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3551-3558. |
[2] |
YANG Jing1, LI Li1, LIANG Jian-dan1, HUANG Shan1, SU Wei1, WEI Ya-shu2, WEI Liang1*, XIAO Qi1*. Study on the Interaction Mechanism Between Thiosemicarbazide Aryl Ruthenium Complexes and Human Serum Albumin[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2761-2767. |
[3] |
LIU Gang1, LÜ Jia-ming1, NIU Wen-xing1, LI Qi-feng2, ZHANG Ying-hu2, YANG Yun-peng2, MA Xiang-yun2*. Detection of Sulfur Content in Vessel Fuel Based on Hyperspectral
Imaging Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1697-1702. |
[4] |
ZONG Zhi-fang1, 2, 3, LONG Hong-ming1*, Yilin Gui3*, ZHANG Hao1, 2, DONG Wei2, ZHOU Xiao-hui2, JI Yi-long1. Microstructure Characteristics of Nano Solid Waste High Sulfur Cement Based on XRD and FTIR[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1974-1980. |
[5] |
FENG Xiang-yu, JIANG Na, WANG Wei, LI Meng-qian, ZHAO Su-ling*, XU Zheng. One-Step Synthesis of Sulfur Quantum Dots and Electroluminescent Properties[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1569-1574. |
[6] |
ZHOU Qing-chao. Preparation and Optical Characterization of Copper Indium Sulfide Nanocrystal/PMMA Composite Film[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(12): 3672-3677. |
[7] |
SONG Jiang-tao, YUAN Yue-hua, ZHU Yong-jun, WANG Yu-zhen, TIAN Mao-zhong*, FENG Feng*. Research Progress of Near-Infrared Fluorescent Probes for Hydrogen Sulfide[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(11): 3321-3329. |
[8] |
WANG Lu1, SUN Feng1, 2*, WANG Ruo-su1, LIANG Ya-xin1, YAO Xue3, ZHAO Fan4. Analysis and Research on Color Paints for Cliff Statues in Qionglai Caves[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(10): 3198-3202. |
[9] |
GE Deng-yun, XU Min-min, YUAN Ya-xian*, YAO Jian-lin*. Surface-Enhanced Raman Spectroscopic Investigation on the Effect of
Solution pH on Dehydroxylation of Hydroxythiophenol Isomers[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(07): 2076-2081. |
[10] |
YANG Qiao-ling1, 2, CHEN Qin2, NIU Bing2, DENG Xiao-jun3*, MA Jin-ge3, GU Shu-qing3, YU Yong-ai4, GUO De-hua3, ZHANG Feng5. Visualization of Thiourea in Bulk Milk Powder Based on Portable Raman Hyperspectral Imaging Technology On-Site Rapid Detection Method
Research[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(07): 2156-2162. |
[11] |
ZHANG Li-sheng. Photocatalytic Properties Based on Graphene Substrate[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1058-1063. |
[12] |
PENG Wu-di1, NING Jia-lian2, CHEN Zhi-li1*, TANG Jin1, LIU Li-xi1, CHEN Lin1. Construction of CS2 Combustion Flame Spectral Radiation Model and Inversion of Characteristic Pollution Product Concentration[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(03): 672-677. |
[13] |
DU Jing1,JIN Tao2, HU Feng-dan1, ZHANG Chi1, ZHU Tie-quan3, ZHAN Chang-fa3, LI Nai-sheng1, JIA Zheng1, CHEN Yue1*. Desalination Monitoring of Wooden Shipwreck Components of the Qing Dynasty Marine Shipwreck,Xiaobaijiao No.1[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3294-3298. |
[14] |
ZHANG Bin-bin1, 2, LI Jing-bin1, 2, WANG Shi-ning1, 2, HE Peng-fei1, 2, ZHA Xiao-qin1, 2, 3. Determination of Lithium, Iron and Phosphorus in Carbon Composite Lithium Iron Phosphate by Perchloric Acid Digestion-Inductively Coupled Plasma Optical Emission Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2703-2709. |
[15] |
JULDEZ Nurlan1,2,3, SHEN Jian1,2,3, LENG Xiao-ting3, CHAI Yi-di1,2,3, WANG Shi-feng3, HU Yuan3, CUI Hao-yue3, WU Jing1,2,3*. Study on Measurement of Mercury Ion in Water by Thiamine-Fluorescence Excitation-Emission Matrix[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(06): 1846-1851. |
|
|
|
|