光谱学与光谱分析 |
|
|
|
|
|
Biological Process Oriented Online Fourier Transform Infrared Spectrometer |
XIE Fei, WU Qiong-shui*, ZENG Li-bo* |
School of Electronic Information, Wuhan University, Wuhan 430079,China |
|
|
Abstract An online Fourier Transform Infrared Spectrometer and an ATR (Attenuated Total Reflection) probe, specifically at the application of real time measurement of the reaction substrate concentration in biological processes, were designed. (1) The spectrometer combined the theories of double cube-corner reflectors and flat mirror, which created a kind of high performance interferometer system. The light path folding way was utilized to makes the interferometer compact structure. Adopting double cube-corner reflectors, greatly reduces the influence of factors in the process of moving mirror movement such as rotation, tilt, etc. The parallelogram oscillation flexible support device was utilized to support the moving mirror moves. It cancelled the friction and vibration during mirror moving, and ensures the smooth operation. The ZnSe splitter significantly improved the hardware reliability in high moisture environment. The method of 60° entrance to light splitter improves the luminous flux. (2)An ATR in situ measuring probe with simple structure, large-flux, economical and practical character was designed in this article. The transmission of incident light and the light output utilized the infrared pipe with large diameter and innerplanted-high plating membrane, which conducted for the infrared transmission media of ATR probe. It greatly reduced the energy loss of infrared light after multiple reflection on the inner wall of the light pipe. Therefore, the ATR probe obtained high flux, improved the signal strength, which make the signal detected easily. Finally, the high sensitivity of MCT (Mercury Cadmium Telluride) detector was utilized to realize infrared interference signal collection, and improved the data quality of detection. The test results showed that the system yields the advantages of perfect moisture-proof performance, luminous flux, online measurement, etc. The designed online Fourier infrared spectrometer can real-time measured common reactant substrates such as glycerin in the bioreactor under high quality. There is a large potential market, such as online analysis in biological, chemical testing and material analysis.
|
Received: 2014-07-16
Accepted: 2014-10-25
|
|
Corresponding Authors:
WU Qiong-shui, ZENG Li-bo
E-mail: qswu@whu.edu.cn;lbzeng@whu.edu.cn
|
|
[1] John Dahlbacka, Kristiina Kiviharju, Tero Eerikinen, et al. Biotechnol. Lett., 2013, 35: 337. [2] Mazarevica Gunta, Diewok Josef, Baena Josefa R, et al. Applied Spectroscopy, 2004, 58(7):804. [3] Jakob J Müller, Markus Neumann, Paul Scholl, et al. Analytical Chemistry, 2010, 83(14): 6008. [4] Raphal Desbiens, Jérme Genest, Pierre Tremblay. Applied Optics, 2002, 41(7): 1424. [5] Milan Milosevic. Internal Reflection And Atr Spectroscopy: John Wiley&Sons,Inc., Hoboken New Jersoy, USA, 2012. [6] WENG Shi-fu(翁诗甫). Fourier Transform Infrared Spectroscopy Analysis(傅里叶变换红外光谱分析). Beijing: Chemical Industry Press(北京:化学工业出版社),2010. 62. [7] James A Harrington. Fiber and Integrated Optics, 2000, 19(3): 211. [8] Vlikyl T, Kauppinen J. Applied Optics, 2011, 50(36): 6671. [9] Dahlbacka J, Kiviharju K, Eerikinen T. Biotechnol Letters,2013,35(3): 337. [10] Melanie M Beasleya, Eric J Bartelinkb, Lacy Taylor. Journal of Archaeological Science,2014, 46: 16. |
[1] |
DING Fan, ZENG Li-bo, WU Qiong-shui*. Automatic Regulating System Design for Fourier Infrared Spectrometer Beam Splitter[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2937-2942. |
[2] |
SHI Lei1,LIU Jia2,GAO Wu1,ZHANG Qian-xuan1,WANG Wei1. The Design of an ATR Probe for Online Monitoring of Biological Process[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(06): 1954-1958. |
[3] |
LI Dan1, FENG Wei-wei2*, CHEN Ling-xin2, ZHANG Jun1* . An On-Line Monitoring System for Nitrate in Seawater Based on UV Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(02): 442-444. |
[4] |
LIU Peng, LI Kai, ZENG Li-bo*, WU Qiong-shui* . Hadamard Transform NIR Spectrometer for the Biological Processes [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(09): 2654-2659. |
[5] |
XIE Fei, FENG Fei, WANG Fu-bei, WU Qiong-shui*, ZENG Li-bo* . Moving Mirror Scanning System Based on the Flexible Hinge Support [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(08): 2343-2347. |
[6] |
ZHAO An-xin1, 2, TANG Xiao-jun1*, WANG Er-zhen1, ZHANG Zhong-hua1, 3, LIU Jun-hua1 . Quantitative Analysis of Transformer Oil Dissolved Gases Using FTIR [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(09): 2407-2410. |
[7] |
SHI Lei, LI Kai, GAO Zhi-fan, ZENG Li-bo, WU Qiong-shui* . Design of A Compact Structure Interferometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(08): 2294-2298. |
[8] |
HOU Di-bo1, ZHANG Jian1, CHEN Lin2, HUANG Ping-jie1, ZHANG Guang-xin1 . Water Quality Analysis by UV-Vis Spectroscopy: A Review of Methodology and Application[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(07): 1839-1844. |
[9] |
SHI Lei, LIU Jia, ZHENG Xin-wen, ZENG Li-bo, WU Qiong-shui*. An Interferometer Design for Fourier Transform Infrared Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(06): 1712-1716. |
[10] |
ZHANG Min-juan2, ZHANG Ji-long1, 2*, WANG Zhi-bin1, 2, JING Ning2, HAO Jian2 . Phase Correction Technology Research and Improvement Based on Single-Sided Interferograms in FTIR [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(05): 1203-1208. |
[11] |
ZHAO You-quan1, 2, ZOU Rui-jie1, CHEN Yu-bang3, FANG Yan-jun4 . Research on Detection of Oil in Water Based on Near-Infrared Scattering Method [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(05): 1213-1216. |
[12] |
YANG Hui-hua1, GUO Tuo2, MA Jin-fang3, TANG Tian-biao2, LIANG Qiong-lin4, WANG Yi-ming4, LUO Guo-an4 . A Novel Online Process Monitoring Method Based on Near Infrared Spectroscopy and Its Application to the Column Chromatographic Separation for Traditional Chinese Medicine[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(05): 1247-1250. |
[13] |
LI Sheng, GAO Min-guang, ZHANG Yu-jun, LIU Wen-qing, XU Liang, TONG Jing-jing, CHENG Si-yang, JIN Ling,WEI Xiu-li, WANG Ya-ping, CHEN Jun. Monitoring and Analysis of Urban Ozone Using Open Path Fourier Transform Infrared Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(12): 3256-3259. |
[14] |
YU Bo-fan1, 2, WEN Li-li2, SONG Yong-hui2*, LIU Hong-liang1, 2, LI Hai-yang3, CUI Hua-peng3, XIE Bin-yu2, SI Ji-hong2. Realtime Analysis of Volatile Organic Compounds in Source Water by Membrane Inlet/Time-of-Flight Mass Spectrometry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(08): 2259-2262. |
[15] |
FU Jian-guo1,2,LIANG Zhong-zhu1,LIANG Jing-qiu1* . Influence of Extended Light Source on Spectral Reconstruction in a Micro FTIR [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(06): 1723-1726. |
|
|
|
|