光谱学与光谱分析 |
|
|
|
|
|
Measurement of Oxygen Concentration Using Multimode Diode Laser Absorption Spectroscopy |
GAO Guang-zhen1, 2, CAI Ting-dong2*, HU Bo1, JIA Tian-jun1 |
1. Department of Optical Engineering, Binzhou University, Binzhou 256603, China 2. College of Physics and Electronic Engineering, Jiangsu Normal University, Xuzhou 221116, China |
|
|
Abstract Tunable diode laser absorption spectroscopy (TDLAS) is a widely used technique for high sensitivity, good selectivity and fast response. It is widely used in environment monitoring, industrial process control and biomedical sensing. In order to overcome the drawbacks of TDLAS including high cost, poor stability and center wavelength shift problem. A multi-mode diode laser system based on correlation spectroscopy and wavelength modulation spectroscopy (TMDL-COSPEC-WMS) was used to measure O2 concentration near 760nm at the 1%~30% range of near room temperature. During the experiment, the light is splitter into two beams, respectively through the sample and measuring cell, two receiving optical signal collection containing gas concentration information sent back stage treatment, invert the oxygen concentration through correlation and ratio between measured signal and reference signal, the correlation spectroscopy harmonic detection technique is used to improve the stability of the system and the signal to noise ratio. The result showed that, there was a good linear relationship between the measured oxygen concentration and the actual concentration value. A detection limit of 280 pmm﹒m in the 1 atmospheric which approved of the same sample. A continuous measurement for oxygen with the standard deviation of 0.056% in ambient air during approximately 30minutes confirms the stability and the capability of the system. The design of the system includes soft and hardware can meet the needs of oxygen online monitoring. The experimental device is simple and easy to use, easy to complex environment application.
|
Received: 2013-12-30
Accepted: 2014-05-24
|
|
Corresponding Authors:
CAI Ting-dong
E-mail: caitingdong@126.com
|
|
[1] Sandstrom L, Malmberg D. Spectrochim. Acta A, 2002, 58(11): 2449. [2] Burke C S, Moore J P, Wencel D A, et al. Journal of Biomedical Optics, 2008, 13(1): 014027. [3] Moos R, Menesklou W, Schreiner H J, et al. Sensors and Actuators B, 2000, 67(1-2): 178. [4] Lee J H. Journal of Materials Science, 2003, 38(21): 4247. [5] Shao J, Gao X, Deng L, et al. Chinese Physics Letter, 2004, 21(10): 1908. [6] LIU Wen-qing, CUI Zhi-cheng, LIU Jian-guo, et al(刘文清, 崔志成, 刘建国, 等). Chinese Journal of Quantum Electronics(量子电子学报), 2004, 21(4): 202. [7] Lou X, Somesfalean G, Chen B, et al. Applied Optics, 2009, 48(5): 990. [8] Lou X, Somesfalean G, Xu F, et al. Applied Physics B, 2008, 93(2): 671. [9] Lou X, Somesfalean G, Chen B, et al. Optics Letters, 2010, 35(11): 1749. [10] Cai T, Wang G, Jia H, et al. Sensor and Actuator A: Physics,2009, 152(1): 5. [11] Li H, Farooq A, Rieker G B, et al. Applied Physics B, 2007, 89(2-3): 407. |
[1] |
WANG Yi-hong, ZHOU Bin*, ZHAO Rong, WANG Bu-bin. Calibration-Free Wavelength Modulation Spectroscopy for Gas Properties Measuring Basedon 2nd and 4th Harmonics[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(02): 368-373. |
[2] |
ZHANG Xiao-teng, LIU Wei, LIU Hai-feng*, ZHENG Zun-qing, MING Zhen-yang, CUI Yan-qing, WEN Ming-sheng, YAO Ming-fa. Intensity Distribution and Inversion Reconstruction of Spectrum of
Hydroxyl Radicals in Spray Combustion of PODE Under Different
Environmental Oxygen Concentrations[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(08): 2587-2594. |
[3] |
WANG Guo-shui1, GUO Ao2, LIU Xiao-nan1, FENG Lei1, CHANG Peng-hao1, ZHANG Li-ming1, LIU Long1, YANG Xiao-tao1*. Simulation and Influencing Factors Analysis of Gas Detection System Based on TDLAS Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3262-3268. |
[4] |
ZOU Li-chang1, HUANG Jun4, LI Zheng-hui1, DENG Yao1, SHAO Guo-dong1, RUAN Zhen4, LU Zhi-min1, 2, 3, YAO Shun-chun1, 2, 3*. Research on Correction Method of Background Signal Drift in Mid-Infrared Harmonic Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(02): 408-413. |
[5] |
WAN Liu-jie1, 2, ZHEN Chao3, QIU Zong-jia1, LI Kang1, MA Feng-xiang3, HAN Dong1, 2, ZHANG Guo-qiang1, 2*. Research of High Precision Photoacoustic Second Harmonic Detection Technology Based on FFT Filter[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 2996-3001. |
[6] |
XIE Ying-chao1,2, WANG Rui-feng1,2, CAO Yuan1,2, LIU Kun1*, GAO Xiao-ming1,2. Research on Detecting CO2 With Off-Beam Quartz-Enhanced Photoacoustic Spectroscopy at 2.004 μm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2664-2669. |
[7] |
CHEN Shu-wang1, WANG Zhao-zhao1, TANG Dong-lin2. Research on Low Cost Hydrogen Sulfide Sensor Based on Spectral Absorption[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 611-615. |
[8] |
ZHU Gao-feng1, 2, HU Xin1, ZHU Hong-qiu1*, HU En-ze1, ZHU Jian-ping3. The Multi-Beam Interference Suppression for Measuring Penicillin Vial’s Oxygen Concentration Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 372-376. |
[9] |
ZHU Gao-feng1,2, YANG Chun-hua1, ZHU Hong-qiu1*, GUI Wei-hua1. Oxygen Concentration Detection and Calibration Method Improvement in Pharmaceutical Vial Based on Wavelength Modulation Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3133-3137. |
[10] |
ZHAO Ying1, ZHAO Xue-hong1,2*, WANG Zhe1, ZHANG Rui1,3, WANG Yan1 . A New Method for Eliminating Background Signal Drift to Improve the Detection Precision in Continuous Harmonic Detection [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(11): 3224-3229. |
[11] |
YAN Jie, ZHAI Chang, WANG Xiao-niu, HUANG Wen-ping . The Research of Oxygen Measurement by TDLAS Based on Levenberg-Marquardt Nonlinear Fitting[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(06): 1497-1500. |
[12] |
SHAO Jie1, HAN Ye-xing1, GUO Jie1, WANG Li-ming1, HAN Ying1, YING Chao-fu1, WANG Yao2 . Research on Spectrum Technology Based on SG-DBR Laser [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(07): 1774-1779. |
[13] |
SHAO Xin1, 2, LIU Fu-gui1, DU Zhen-hui3*, WANG Wei3 . Absorption Spectrum of Quasi-Continuous Laser Modulation Demodulation Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(05): 1186-1190. |
[14] |
GAO Guang-zhen1, 2, CHEN Bao-xue1, 3*, HU Bo2, LONG Xiu-hui2, LI Ai-ping2,LI Rong2 . Study on CO2 Measurement Using Tunable Multi-Mode Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(12): 3269-3272. |
[15] |
FAN Jie, CHEN Xiao*, HUANG Qi-feng, ZHOU Yu, CHEN Gang . Study on High Accuracy Detection of Multi-Component Gas in Oil-Immerse Power Transformer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(12): 3326-3329. |
|
|
|
|