光谱学与光谱分析 |
|
|
|
|
|
Measurement and Application of CO2 Spectroscopic Parameters near 2.0 μm |
SUN Ming-guo1, 2, MA Hong-liang1, CAO Zhen-song1*, LIU Qiang1, WANG Gui-shi1,2, CHEN Wei-dong2, 3, GAO Xiao-ming1,2* |
1. Key Laboratory of Atmospheric Composition and Optical Radiation, Chinese Academy of Sciences, Hefei 230031, China 2. Laboratory of Atmospheric Physico-Chemistry, Anhui Institute of Optics & Fine Mechanics, Chinese Academy of Sciences, Hefei 230031, China 3. Laboratoire de Physicochimiedel’Atmosphère, Université du Littoral Cte d’Opale, 189A, Av, Maurice Schumann, 59140 Dunkerque, France |
|
|
Abstract The accuracy of absorption spectral parameters is very important for the trace gas measurement based on absorption spectroscopy techniques, especially for the isotopic abundance measurement of gas molecules. For some of the applications, spectral parameters listed in HITRAN database were used to retrieve the trace gas concentration. However, these parameters have uncertainty, in order to validate spectroscopic parameters near 2.0 μm of CO2 lines, which are to be used in detecting the CO2 concentration and isotopic abundance, spectra of those lines were recorded at room temperature using a distributed feed-back (DFB) diode laser. The recorded absorption spectra were fitted to Voigt profile. Line position, intensity, self-broadening coefficient and N2-broadening coefficient were deduced from those data. The results show a good consistency in comparison with those listed in HITRAN2012 database. The discrepancy of most line intensities and self-broadening coefficients are less than 2%. The CO2 concentration and δ(13CO2)in real atmosphere inside laboratory are 440 ppm and -9‰ respectively. These results provide a reliable basis for real time and on line detecting the CO2 concentration and δ(13CO2)in the wavelength range.
|
Received: 2013-12-14
Accepted: 2014-05-06
|
|
Corresponding Authors:
CAO Zhen-song,GAO Xiao-ming
E-mail: xmgao@aiofm.ac.cn;zscao@aiofm.ac.cn
|
|
[1] Regalia J L, Zeninari V, Parvitte B, et al. J. Quant. Specstrosc. Rad. Transfer, 2006, 101: 325. [2] Castrillo A, Casa G, Van Burgel M, et al. Optics Express, 2004, 12: 6515. [3] Andreev S N, Mironchuk E S, Nikolaev I V, et al. Appl. Phys. B, 2011, 104: 73. [4] Dufour E, Breon F M. Appl. Opt.,2003, 42: 3595. [5] Tolton B T, Plouffe D. Appl. Opt.,2001, 40: 1305. [6] Durry G, Amarouche N, Zeninari V, et al. Spectrochim. Acta A, 2004, 60: 3371. [7] Tanaka K, Tonolura K. Appl. Phys. B, 2011, 105: 463. [8] Mironchuk E S, Nikolaev I V, Ochkin V N, et al. Quant. Electronics, 2009, 39: 388. [9] Valero F P J,Suarez C B,Boese R W. J. Quant. Spectrosc. Rad. Transfer,1980,23:337. [10] Arcas P, Arie E, Cuisenier M, et al. J. Phys.,1983, 61: 857. [11] Miller C E, Brown L R. J. Mol. Spectrosc., 2004, 228: 329. [12] Toth R A, Brown L R, Miller C E, et al. J. Mol. Spectrosc.,2006, 239: 221. [13] Toth R A, Brown L R, Miller C E, et al. J. Mol. Spectrosc.,2006, 239: 243. [14] Toth R A, Miller C E, Malathy V, et al. J. Mol. Spectrosc.,2007, 133. [15] Brownsword R A, Salh J S, Smith lan W M. J. Chem. Soc. Faraday Trans.,1995, 91: 191. [16] Mihalcea R M, Baer D S, Hanson R K. Appl. Opt., 1998, 37: 8341. [17] Corsi C, Amato F D, De Rosa M, et al. Eur. Phys. J. D, 1999, 6: 327. [18] Matthias Cuntz. Nature, 2011, 477: 547. |
[1] |
LIANG Wen-ke, WEI Guang-fen, WANG Ming-hao. Research on Methane Detection Error Caused by Lorentzian Profile Approximation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(06): 1683-1689. |
[2] |
ZHANG Li-fang1, YANG Yan-xia1, ZHAO Guan-jia1, MA Su-xia1, GUO Xue-mao2. Comparison of Numerical Iterative Algorithms for Two-Dimensional Absorption Spectral Reconstruction[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1367-1375. |
[3] |
ZHANG Le-wen1, 2, WANG Qian-jin1, 3, SUN Peng-shuai1, PANG Tao1, WU Bian1, XIA Hua1, ZHANG Zhi-rong1, 3, 4, 5*. Analysis of Interference Factors and Study of Temperature Correction Method in Gas Detection by Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 767-773. |
[4] |
LONG Jiang-xiong1, 2, ZHANG Yu-jun1*, SHAO Li1*, YE Qing1, 2, HE Ying3, YOU Kun3, SUN Xiao-quan1, 2. Traceable Measurement of Optical Path Length of Gas Cell Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(11): 3461-3466. |
[5] |
JIANG Ya-jing, SONG Jun-ling*, RAO Wei, WANG Kai, LOU Deng-cheng, GUO Jian-yu. Rapid Measurement of Integrated Absorbance of Flow Field Using Extreme Learning Machine[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(05): 1346-1352. |
[6] |
DU Bao-lu, LI Meng, GUO Jin-jia*, ZHANG Zhi-hao, YE Wang-quan, ZHENG Rong-er. The Experimental Research on In-Situ Detection for Dissolved CO2 in
Seawater Based on Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1264-1269. |
[7] |
MA Li1, 2, FAN Xin-li1, 2, ZHANG Shuo1, 2, WANG Wei-feng1, 2, WEI Gao-ming1, 2. Research on CH4 Gas Detection and Temperature Correction Based on TDLAS Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(11): 3632-3638. |
[8] |
SHAO Guo-dong1, LI Zheng-hui1, GUO Song-jie1, ZOU Li-chang1, DENG Yao1, LU Zhi-min1, 2, 3, YAO Shun-chun1, 2, 3*. Research on Gas Concentration Measurement Method Based on Gradient Descent Method to Fit Spectral Absorption Signal Directly[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3256-3261. |
[9] |
WANG Guo-shui1, GUO Ao2, LIU Xiao-nan1, FENG Lei1, CHANG Peng-hao1, ZHANG Li-ming1, LIU Long1, YANG Xiao-tao1*. Simulation and Influencing Factors Analysis of Gas Detection System Based on TDLAS Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3262-3268. |
[10] |
PAN Sun-qiang, HU Peng-bing, CHEN Zhe-min, ZHANG Jian-feng, LIU Su-mei. Measurement of Vapor Hydrogen Peroxide Based on Mid Infrared Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(04): 1102-1106. |
[11] |
ZOU Li-chang1, HUANG Jun4, LI Zheng-hui1, DENG Yao1, SHAO Guo-dong1, RUAN Zhen4, LU Zhi-min1, 2, 3, YAO Shun-chun1, 2, 3*. Research on Correction Method of Background Signal Drift in Mid-Infrared Harmonic Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(02): 408-413. |
[12] |
NA Yi-jun, LI Ning*, HUANG Xiao-long, WENG Chun-sheng. Research of Two-Dimensional Reconstruction of Combustion of Tunable Diode Laser Absorption Spectroscopy Based on Virtual Beam and Re-Projection Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3686-3691. |
[13] |
QUE Hua-li1, 2, YANG Wen-liang1, XIN Xiu-li1, MA Dong-hao1, ZHANG Xian-feng1, ZHU An-ning1*. Ammonia Volatilization from Farmland Measured by Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(03): 885-890. |
[14] |
SHANG Hou-fei1, DU Zhen-hui2, 3, GAO Nan1, 3*, LI Jin-yi4, XIAO Yan-jun1, MENG Zhao-zong1, ZHANG Zong-hua1. Parameter Analysis of Tunable Diode Laser Absorption Spectroscopy Based on Spectral Frequency Characteristics[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(11): 3359-3364. |
[15] |
XIAO Hu-ying1, YANG Fan1, XIANG Liu1, HU Xue-jiao2*. Jet Vacuum Enhanced Tunable Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(10): 2993-2997. |
|
|
|
|