光谱学与光谱分析 |
|
|
|
|
|
Absorption Spectrum of Quasi-Continuous Laser Modulation Demodulation Method |
SHAO Xin1, 2, LIU Fu-gui1, DU Zhen-hui3*, WANG Wei3 |
1. Province-Ministry Joint Key Lab of Electromagnetic Field and Electrical Apparatus Reliability, Hebei University of Technology,Tianjin 300401,China 2. Electrical and Electronics Technology Application Department, Tianjin Institute of Mechanical and Electronic Technology, Tianjin 300131,China 3. State Key Laboratory of Precision Measuring Technology and Instruments (Tianjin University), Tianjin 300072, China |
|
|
Abstract A software phase-locked amplifier demodulation method is proposed in order to demodulate the second harmonic (2f) signal of quasi-continuous laser wavelength modulation spectroscopy (WMS) properly, based on the analysis of its signal characteristics. By judging the effectiveness of the measurement data, filter, phase-sensitive detection, digital filtering and other processing, the method can achieve the sensitive detection of quasi-continuous signal. The method was verified by using carbon dioxide detection experiments. The WMS-2f signal obtained by the software phase-locked amplifier and the high-performance phase-locked amplifier (SR844) were compared simultaneously. The results show that the Allan variance of WMS-2f signal demodulated by the software phase-locked amplifier is one order of magnitude smaller than that demodulated by SR844, corresponding two order of magnitude lower of detection limit. And it is able to solve the unlocked problem caused by the small duty cycle of quasi-continuous modulation signal, with a small signal waveform distortion.
|
Received: 2013-07-17
Accepted: 2013-10-25
|
|
Corresponding Authors:
DU Zhen-hui
E-mail: duzhenhui@tju.edu.cn
|
|
[1] XIA Hui,LIU Wen-qing,ZHANG Yu-jun,et al(夏 慧, 刘文清, 张玉钧, 等). Acta Optica Sinica(光学学报), 2009, 29(6): 1454. [2] Lackner M. Rev. Chem. Eng., 2007, 23: 65. [3] WANG Jian, HUANG Wei, GU Hai-tao, et al(王 健, 黄 伟, 顾海涛, 等). Acta Optica Sinica(光学学报), 2007, 27(9): 1639. [4] Were P. Spectro. Acta A, 1998, 54(2): 197. [5] Allen M G. Sci. Technol., 1998, 9(4): 545. [6] Namjou K, Cai S, Whittaker E A, et al. Opt. Lett., 1998, 23: 219. [7] Weidmann D, Tittel F K, Aellen T, et al. Appl. Phys. B, 2004, 79(7): 907. [8] Kunsch J. Abstracts of 5th International Conference on Tunable Diode Laser Spectroscopy, Florence, 2005. 22. [9] Taslakov M, Simeonov V, van den Bergh H. Abstracts of 5th International Conference on Tunable Diode Laser Spectroscopy, Florence, 2005. 106. [10] Thorsten F, Thomas W. Frequenz, 2008, 62(3-4): 84. [11] Tittel F K, Bakhirkin Y, Kosterev A A, et al. Rev. Laser. Eng., 2006, 34: 275. [12] DU Zhen-hui, ZHAI Ya-qiong, HU Bo, et al(杜振辉,翟雅琼,胡 波,等). Nanotechn. Precis. Eng.(纳米技术与精密工程), 2010, 8(2): 24. [13] Kosterev A A, Curl R F, Tittel F K, et al. Appl. Phys. B: Lasers and Optics, 2002, 75(2-3): 351. |
[1] |
ZHANG Li-fang1, YANG Yan-xia1, ZHAO Guan-jia1, MA Su-xia1, GUO Xue-mao2. Comparison of Numerical Iterative Algorithms for Two-Dimensional Absorption Spectral Reconstruction[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1367-1375. |
[2] |
WANG Yi-hong, ZHOU Bin*, ZHAO Rong, WANG Bu-bin. Calibration-Free Wavelength Modulation Spectroscopy for Gas Properties Measuring Basedon 2nd and 4th Harmonics[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(02): 368-373. |
[3] |
WANG Guo-shui1, GUO Ao2, LIU Xiao-nan1, FENG Lei1, CHANG Peng-hao1, ZHANG Li-ming1, LIU Long1, YANG Xiao-tao1*. Simulation and Influencing Factors Analysis of Gas Detection System Based on TDLAS Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3262-3268. |
[4] |
PAN Sun-qiang, HU Peng-bing, CHEN Zhe-min, ZHANG Jian-feng, LIU Su-mei. Measurement of Vapor Hydrogen Peroxide Based on Mid Infrared Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(04): 1102-1106. |
[5] |
ZOU Li-chang1, HUANG Jun4, LI Zheng-hui1, DENG Yao1, SHAO Guo-dong1, RUAN Zhen4, LU Zhi-min1, 2, 3, YAO Shun-chun1, 2, 3*. Research on Correction Method of Background Signal Drift in Mid-Infrared Harmonic Detection[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(02): 408-413. |
[6] |
WAN Liu-jie1, 2, ZHEN Chao3, QIU Zong-jia1, LI Kang1, MA Feng-xiang3, HAN Dong1, 2, ZHANG Guo-qiang1, 2*. Research of High Precision Photoacoustic Second Harmonic Detection Technology Based on FFT Filter[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 2996-3001. |
[7] |
XIE Ying-chao1,2, WANG Rui-feng1,2, CAO Yuan1,2, LIU Kun1*, GAO Xiao-ming1,2. Research on Detecting CO2 With Off-Beam Quartz-Enhanced Photoacoustic Spectroscopy at 2.004 μm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2664-2669. |
[8] |
CHEN Shu-wang1, WANG Zhao-zhao1, TANG Dong-lin2. Research on Low Cost Hydrogen Sulfide Sensor Based on Spectral Absorption[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(02): 611-615. |
[9] |
LIU Yong-sheng, HE Jian-jun*, ZHU Gao-feng, YANG Chun-hua, GUI Wei-hua. A New Method for Second Harmonic Baseline Correction and Noise Elimination on Residual Oxygen Detection in Packaged Xilin Bottle[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2598-2602. |
[10] |
ZHAO Ying1, ZHAO Xue-hong1,2*, WANG Zhe1, ZHANG Rui1,3, WANG Yan1 . A New Method for Eliminating Background Signal Drift to Improve the Detection Precision in Continuous Harmonic Detection [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(11): 3224-3229. |
[11] |
XIA Hui-hui, LIU Jian-guo, XU Zhen-yu, KAN Rui-feng, HE Ya-bai, ZHANG Guang-le, CHEN Jiu-ying . Reconstruction Research for Gas Concentration and Temperature of Flame Based on Algebraic Reconstruction Technique[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(10): 2697-2702. |
[12] |
ZHANG Li-fang, WANG Fei*, YU Li-bin, YAN Jian-hua, CEN Ke-fa . The Research for Trace Ammonia Escape Monitoring System Based on Tunable Diode Laser Absorption Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(06): 1639-1642. |
[13] |
GAO Guang-zhen1, 2, CAI Ting-dong2*, HU Bo1, JIA Tian-jun1 . Measurement of Oxygen Concentration Using Multimode Diode Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(01): 34-37. |
[14] |
SHAO Jie1, HAN Ye-xing1, GUO Jie1, WANG Li-ming1, HAN Ying1, YING Chao-fu1, WANG Yao2 . Research on Spectrum Technology Based on SG-DBR Laser [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(07): 1774-1779. |
[15] |
FAN Jie, CHEN Xiao*, HUANG Qi-feng, ZHOU Yu, CHEN Gang . Study on High Accuracy Detection of Multi-Component Gas in Oil-Immerse Power Transformer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(12): 3326-3329. |
|
|
|
|