光谱学与光谱分析 |
|
|
|
|
|
Test Equipment for Relative Spectral Response of CCD |
YAN Feng, ZHOU Yue*, ZHANG Ming-chao, CHEN Xue |
State Key Lab of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China |
|
|
Abstract The auto-test equipment for relative spectral response of charge coupled devices (CCD) was designed and realized. The equipment covered the range of 400 to 950 nm. Firstly, testing theory of relative spectral response for detectors was introduced. Secondly, taking the high sensitive and broad spectral scientific spectrometer-QE65000 as reference, auto-test equipment for relative spectral response was built up by direct comparison method in the same radiation field. Uncertainty analysis showed that the maximum uncertainty of the equipment was less than 6.21%. This auto-test equipment can be used in the CCD assessment and its photoelectrical parameters testing.
|
Received: 2013-01-31
Accepted: 2013-04-08
|
|
Corresponding Authors:
ZHOU Yue
E-mail: zhouy385@ciomp.ac.cn
|
|
[1] YUE Jun-hua, LI Yan, WU Xue-ying et al(岳俊华,李 岩,武学颍,等). Optics and Precision Engineering(光学精密工程),2009, 17(12): [2] Mazurenka M, Jelzow A, Ebert B,et al. SPIE Proceedings,2011, 8088: 340. [3] Greer F, Hamden E, Jacquot B C, et al. Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films,2013, 31(1): 01A103. [4] Valeriano F P, Sandy P N, Karsten F,et al. Light: Science & Applications. (2012) 1, e36; doi:10.1038/lsa.2012.36. [5] MIAO Jian-yu, ZHANG Li-ping, ZHAI Yan,et al(苗健宇,张立平,翟 岩,等). Chinese Optics(中国光学),2012, 5(4): 367. [6] Stern A, Aloni D, Javidi B. Photonics Jouranl, IEEE,2012, 4(4): 1188. [7] Muller K, Ryll H, Ordavo I. Applied Physics Letters,2012, 101(21): 212110. [8] Joseph J T, Anand S G, Ryan P S. Light: Science & Applications,(2012) 1, e24; doi:10.1038/lsa.2012.24. [9] LU Zhen-hua, GUO Yong-fei, LI Yun-fei, et al(卢振华,郭永飞,李云飞,等). Optics and Precision Engineering(光学精密工程),2012, 20(7): [10] ZHANG Hui, LIU Jian-wei, YANG Liang, et al(张 辉,刘建伟,杨 良,等). Laser and Infrared(激光与红外), 2003, 33(5): 371. [11] WANG Zhen-chang, YI Qing-xiang, WANG Jie(王振常,易庆祥,王 捷). ACTA Metrologica Sinica(计量学报), 1990, 11(1): 1. [12] Budde R, Zaaiman W, Ossenbrink H A. Photovoltatic Energy Conversion, 1994, 1: 874. [13] Ken Suk Hong, Dong-Hoon Led, Seongchonge Park,et al. Precision Electromagnetic Measurements(CPEM), 2012 Conferences. 2012, 668. [14] Bakumenko V L, Beguchev V P, Beguchev A S,et al. SPIE Proceedings,2005, 5834: 355. [15] Laurence J Cox,Peter J Key. SPIE Proceedings,1983, 369: 46. |
[1] |
YAN Hua1, LIU Xing-hua2, DING Yong3, ZHAO Zhi1, LUO Yong-feng1, WU Yu-hong1, YAN Peng1, DONG Lu1, WANG Da-xi4. Instantaneous Emission Spectra and Mechanism Study on the Reaction of ClF3O and n-Decane[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(05): 1522-1528. |
[2] |
ZHU Yu-xuan1,2, LU Jing-bin1, ZHAO Xiao-fan2, LIU Xiao-yan4, CUI Wei-wei2, LI Wei2, WANG Yu-sa2, LÜ Zhong-hua2, 3, CHEN Yong2*. An Application of Lucy Richardson Iterative in X-Ray Fluorescence Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2823-2828. |
[3] |
GUO Jun-jie1,2,3,4, YAO Zhi-gang1,4,5*, HAN Zhi-gang1,4, ZHAO Zeng-liang1,4, YAN Wei3, JIANG Jun1,4. On-Orbit Analysis and Correction of the Inconsistency in the Response Characteristics of TG-2/MAI CCD Pixels[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(12): 3953-3962. |
[4] |
DAI Cai-hong, WU Zhi-feng, WANG Yan-fei, LI Ling. Realization of National Primary Standard Apparatus of Spectral Irradiance from 200 to 400 nm[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(08): 2640-2644. |
[5] |
DONG Hai-long, WANG Jia-chun*, ZHAO Da-peng, CHEN Zong-sheng, LIU Rui-huang, SHI Jia-ming. Analysis of Measurement Uncertainty in THz-TDS Carried by Delay-Line Position Deviation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(11): 3379-3384. |
[6] |
ZHANG Quan1, 2, HUANG Shu-hua1*, TIAN Yu-ze1, 2, LU Yue-lin1, 2, ZHAO Min-jie1, ZHOU Hai-jin1, ZHAO Xin1, WANG Yu1, SI Fu-qi1. Noise Analysis and Processing Method of Environment Monitoring Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(09): 2976-2981. |
[7] |
LIU Yuan-yuan1, CHEN Jian-jun2, QIU Bo1*, FAN Xiao-dong1, WEI Shi-ya1, SONG Tao1, DUAN Fu-qing3*. A Processing Method for Low SNR Repetitive Observation Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(07): 2311-2314. |
[8] |
ZHANG Fu-cai1, 2, SUN Xiao-gang1*, XING Jian3. Research of Multi Points and Multi Spectral Calibration in Two-Dimensional Temperature Field Reconstruction Based on CCD[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2283-2287. |
[9] |
WANG Zi-xuan, WU Jian, DAI Chang-jian*. Effect of Environment and Medium on Temperature Measurement[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2128-2132. |
[10] |
LIU Xiao, YANG Xiao-tao, ZHAN Xiu-chun*, YUAN Ji-hai, FAN Xing-tao, JIAO Ju . Solution Cathode Glow Discharge Based on Charge Coupled Device Detector[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(03): 971-977. |
[11] |
GAO Rui-feng1, 2, GAO Meng-chao3, LING Rui3, ZHANG Ning1* . Improving Analytical Methods by Uncertainty Evaluation with the Case of Determination of Aluminum in Starch Products by ICP-MS [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(04): 1211-1216. |
[12] |
LI Yao, DAI Chang-jian* . Precise Temperature Measurement with Imaged Spectral Technique [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(01): 38-41. |
[13] |
DING Zhi-jun, WANG Pu-hong, LI Zhi-jun, DU Bin, GUO Lei, YU Jian-hua* . Analysis of H2S/ PH3/ NH3/ AsH3/ Cl2 by Full-Spectral Flame Photometric Detector[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(07): 2025-2028. |
[14] |
ZHAO Zhi-qiang1, 2, LI Ai-nong1*, BIAN Jin-hu1, 2, HUANG Cheng-quan3 . An Improved DDV Method to Retrieve AOT for HJ CCD Image in Typical Mountainous Areas[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(06): 1479-1487. |
[15] |
XUE Zhong1, XU Bing1*, LIU Qian1, SHI Xin-yuan1, 2, LI Jian-yu1, WU Zhi-sheng1, QIAO Yan-jiang1, 2* . Application of Uncertainty Assessment in NIR Quantitative Analysis of Traditional Chinese Medicine [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(10): 2657-2661. |
|
|
|
|