光谱学与光谱分析 |
|
|
|
|
|
Virtual Design of X-Ray Multi-Spectrum CT Imaging Based on Variable Voltage |
CHEN Ping, HAN Yan, PAN Jin-xiao |
National Key Laboratory for Electronic Measurement Technology, North University of China, Taiyuan 030051, China |
|
|
Abstract In the conventional X-ray imaging, the ray image of the complicated structural component (shape, structure complex and multi-materials) easily exhibits the overexposed and underexposed phenomenon. This is because of the bigger variations in the effective thickness in the orientation of X-ray penetration and the limit of the dynamic range of X-ray imaging system. The complete structure information can’t be obtained, and it will impact the quality of X-ray CT image. So the present paper has improved the theory and method of variable voltage X-ray multi-spectrum CT imaging. The new method changes the distribution of X-ray spectrum by changing the voltage, and can realize the matching between the X-ray spectrum and the effective thickness of workpieces. This can expand the dynamic range and ensure the integrity of projection about the workpieces. At the same time, based on the idea of virtual design, the paper has built the variable voltage virtual CT mode based on single-energy and multi-energy, and realized virtual simulation of the variable voltage X-ray CT. At last, the virtual experiment has proved that the theory and method of variable voltage CT imaging is feasible, and the variable voltage CT imaging is the effective method for the complicated structural component.
|
Received: 2012-01-15
Accepted: 2012-05-12
|
|
Corresponding Authors:
CHEN Ping
E-mail: pc0912@163.com
|
|
[1] Hamideen M S, Sharaf J, Al-Saleh K A, et al. Radiation Physics and Chemistry, 2011, 80: 1162. [2] Francis Zarb, Louise Rainford, Mark F McEntee. Radiography,2010, 16: 147. [3] Lee Ting-Yim, Chhem Rethy K. European Journal of Radiology,2010, 76: 28. [4] Anthony P H Butler, Jochen Butzer, Nanette Schleich, et al. Nuclear Instruments and Methods in Physcis Research A,2011, 633: 140. [5] George X Ding, Peter Munro, Jason Pawlowski,et al. Radiotherapy and Oncology, 2010, 97: 585. [6] Minami Y, Imamura R, Minami Y, et al. Journal of Nuclear Science and Technology, 2011, 48: 108. [7] Ferreira C C, Vieira J W, Maia A F. Nuclear Instruments and Methods in Physcis Research A,2009, 267: 3447. |
[1] |
LIU Hong-yuan1, WU Bin1, 2, JIANG Tao3, YANG Yan-zhao1, WANG Hong-chao1, LI Jing-song1. Study on the Measurement of Absolute Spectral Responsivity of Terahertz Detector[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1017-1022. |
[2] |
ZHU Yu-xuan1,2, LU Jing-bin1, ZHAO Xiao-fan2, LIU Xiao-yan4, CUI Wei-wei2, LI Wei2, WANG Yu-sa2, LÜ Zhong-hua2, 3, CHEN Yong2*. An Application of Lucy Richardson Iterative in X-Ray Fluorescence Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2823-2828. |
[3] |
REN Xue-zhi1, HE Peng1, 2*, LONG Zou-rong1, GUO Xiao-dong1, AN Kang2, LÜ Xiao-jie1, WEI Biao1, 2, FENG Peng1, 2*. Research on Spectral CT Image Denoising Via Fully Convolution Pyramid Residual Network[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2950-2955. |
[4] |
TANG Lin1, 2, ZHAO Wei-dong4, YU Song-ke3*, LIU Ze1*, YU Xiao-dong4, MENG Yuan4, HUANG Xing-lu4. Optimization Design of X-Ray Spectrum Data Processing Platform[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(03): 763-767. |
[5] |
LIU Hong-bo1, SHI Xue-shun1,XU Wen-bin2, LIU Chang-ming1, LIU Hong-yuan1, WANG Heng-fei1. Long-Wave Infrared Absolute Spectral Responsivity Scale by Using an Absolute Cryogenic Radiometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3680-3685. |
[6] |
DAI Li-juan1, DING Le-ming1, LI Wei-tao2, QIAN Zhi-yu2. Study on the Application of Scattering Spectrum With Small Source-Detector Separation in Pain Measurement[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3743-3747. |
[7] |
TANG Lin1,2,3, LIAO Xian-li1*, LIU Xing-yue1, ZHAO Yong-xin1, LI Yue-peng1, YU Song-ke1,3. Study on Correction Algorithms of Characteristic Peak Drift in X-Ray Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3633-3638. |
[8] |
ZHAO Yao-xia, HAN Yan, CHEN Ping*. Blind Separation of Multi-Voltage Projection Sequence Based on Fundamental Effect Decomposition[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(09): 2763-2768. |
[9] |
HE Peng1,2, WU Xiao-chuan1, AN Kang2, DENG Gang3, WANG Xing3, ZHOU Zhong-xing4, WEI Biao1,2, FENG Peng1,2*. Experimental Study of Material K-Edge Characteristics Identification Based on X-ray Photon-Counting Detection Technique[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(12): 3929-3933. |
[10] |
ZHOU Wei, LIU Ze-wei*, ZHOU Hang, LIANG Fei-xi, ZHANG Rong-zhou. Study of the False Peak Eliminating Algorithm in Fine EDXRF[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(11): 3593-3597. |
[11] |
WU Ming-lei, LIU Rong*, XU Ke-xin. Simulation Study of Measurement Method Based on Temperature Insensitive Source-Detector Separation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3163-3168. |
[12] |
CAO Can1, 2, ZHANG Zhao-hui1, 2*, ZHAO Xiao-yan1, 2, ZHANG Han2, 3, ZHANG Tian-yao1, 2, YU Yang1, 2. Review of Terahertz Time Domain and Frequency Domain Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(09): 2688-2699. |
[13] |
ZHAO Dan,CHEN Ping,HAN Yan,LI Yi-hong*. Multi-Spectral CT Sequence DCM Fusion Algorithm Based on Priori Components[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(03): 968-972. |
[14] |
ZHANG Hai-wei1,2, WANG Lei1,2*, LENG Feng-qing1,2*, TUO Xian-guo3, LIU Ming-zhe1,2, CHENG Yi2, YAO Fu-liang2, LI San-gang2, ZHAO Bai-jun2, LU Wei2. Properties and Application Studies of LaBr3(Ce) Scintillation Detector[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2298-2304. |
[15] |
WANG Li, TAN Lin-qiu, CHANG Bo, LU Geng-geng, GAO Fei, HUA Deng-xin* . Doppler Lidar with High Sensitivity and Large Dynamic Range for Atmospheric Wind Measurement[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(03): 958-963. |
|
|
|
|