光谱学与光谱分析 |
|
|
|
|
|
The Analysis for Improving the SNR of Blood Components Noninvasive Measurement with DS Method |
LI Gang1, WANG Hui-quan1, ZHAO Zhe1, LIN Ling1, ZHANG Bao-ju2, WU Xiao-rong2* |
1. State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China 2. College of Physics & Electronic Information, Tianjin Normal University, Tianjin 300387, China |
|
|
Abstract In order to increase the accuracy of blood components measurement and enhance the stability of prediction model, the quantitative signal-noise-ratio (SNR) analysis of measuring instruments based on dynamic spectrum (DS) and preprocessing method was conducted. The SNR of DS is increased after adding boxcar integrator, decreasing wavelength revolution, balancing the DS’s SNR and excluding gross errors in preprocessing according to experiment results. Two volunteers were tested continuously for many times using the DS data acquiring system. The correlation coefficients of the each volunteer’s DS data was increased from 0.934 and 0.953 to 0.991 and 0.987, respectively. Moreover, the gap between the correlation coefficient of the same volunteer’s DS and different volunteers’ DS is increased too, which shows that the SNR can be improved by these methods. The quantitative SNR analysis can guide the way of choosing preprocessing method efficiently, which will create the condition for clinical application of the blood components noninvasive measurement.
|
Received: 2011-11-05
Accepted: 2012-02-21
|
|
Corresponding Authors:
WU Xiao-rong
E-mail: wu.xiaorong@sohu.com
|
|
[1] John W M, Gregory D J, Selim S, et al. Clinical Chemistry, 2008, 54: 264. [2] CHEN Xing-dan(陈星旦). Optics and Precision Engineering(光学精密工程), 2008, 16(5): 759. [3] CHU Xiao-li, YUAN Hong-fu, LU Wan-zhen(褚小立, 袁洪福, 陆婉珍). Progress in Chemistry(化学进展), 2004, 16(4): 528. [4] Khanmohammadi M, Garmarudi A B, Ghasemi K, et al. Microchemical Journal, 2009, 9: 47. [5] Wang Y, Li G, Lin L. Proceeding of the 2005 IEEE Engineering in Medicine and Biology 27th Annual International Conference, Shanghai, 2005. 6679. [6] Yamakoshi K, Yamakoshi Y. Journal of Biomedical Optics, 2006, 11(5): 1. [7] LUO Yun-han, CHEN Zhe, CHEN Xing-dan(罗云瀚,陈 哲,陈星旦). Optics and Precision Engineering(光学精密工程), 2008, 16(5): 784. [8] RUAN Si-xu, ZHUANG Qi-ren, YU Bai-ying(阮思旭, 庄其仁, 于百英). Transducer and Microsystem Technologies(传感器与微系统), 2006, 25(12): 35. [9] Hamoui A A, Maloberti F. ICECS, 2006, Nice, December 12: 123. [10] Wang Huiquan, Li Gang, Zhao Zhe, et al. Lecture Notes in Computer Science, 2010, 6330: 67. [11] Matthew E, Eames, Hamid Dehghani. Optical Express, 2008, 16: 17780.
|
[1] |
LIU Wen-bo, LIU Jin, HAN Tong-shuai*, GE Qing, LIU Rong. Simulation of the Effect of Dermal Thickness on Non-Invasive Blood Glucose Measurement by Near-Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(09): 2699-2704. |
[2] |
GUO Yuan1, 2, HUANG Yi-xiang3, 4, HUANG Chang-ping3, 4, SUN Xue-jian3, 5, LUAN Qing-xian1*, ZHANG Li-fu3, 5*. Analysis of Blood Oxygen Content in Gingival Tissue of Patients With
Periodontitis Based on Visible and Near-Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(08): 2563-2567. |
[3] |
PAN Ke-yu1, 2, ZHU Ming-yao1, 2, WANG Yi-meng1, 2, XU Yang1, CHI Ming-bo1, 2*, WU Yi-hui1, 2*. Research on the Influence of Modulation Depth of Phase Sensitive
Detection on Stimulated Raman Signal Intensity and
Signal-to-Noise Ratio[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1068-1074. |
[4] |
LIU Jin, FU Run-juan, HAN Tong-shuai*, LIU Rong, SUN Di. Spectral Analysis of Human Tissues Based on a Direct Effective
Attenuation Coefficient Measurement[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(09): 2746-2751. |
[5] |
LIU Ye-kun, HAO Xiao-jian*, YANG Yan-wei, HAO Wen-yuan, SUN Peng, PAN Bao-wu. Quantitative Analysis of Soil Heavy Metal Elements Based on Cavity
Confinement LIBS Combined With Machine Learning[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(08): 2387-2391. |
[6] |
WANG Yue1, 3, 4, CHEN Nan1, 2, 3, 4, WANG Bo-yu1, 5, LIU Tao1, 3, 4*, XIA Yang1, 2, 3, 4*. Fourier Transform Near-Infrared Spectral System Based on Laser-Driven Plasma Light Source[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(06): 1666-1673. |
[7] |
YANG Yu-qing1, CAI Jiang-hui1, 2*, YANG Hai-feng1*, ZHAO Xu-jun1, YIN Xiao-na1. LAMOST Unknown Spectral Analysis Based on Influence Space and Data Field[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1186-1191. |
[8] |
HU Li-hong1, ZHANG Jin-tong1, WANG Li-yun2, ZHOU Gang3, WANG Jiang-yong1*, XU Cong-kang1*. Optimization of Working Parameters of Glow Discharge Optical Emission Spectrometry of High Barrier Aluminum Plastic Film[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(03): 954-960. |
[9] |
CUI Fang-xiao1, ZHAO Yue2, MA Feng-xiang2, WU Jun1*, WANG An-jing1, LI Da-cheng1, LI Yang-yu1. Optimization of FTIR Passive Remote Sensing Signal-to-Noise Ratio and Its Application in SF6 Leak Detection in Transform Substation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1436-1440. |
[10] |
XIE Xue-wei2, ZHONG Hao-chen2, CHEN Zhen-cheng2, HE Min2, ZHU Jian-ming1*. Detection of Advanced Glycosylation End Products by Fluorescence Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(04): 1055-1059. |
[11] |
WANG Jing-jing1, 2, TAN Tu1*, WANG Gui-shi1, ZHU Gong-dong1, XUE Zheng-yue1, 2, LI Jun1, 2, LIU Xiao-hai1, 2, GAO Xiao-ming1, 2. Research on All-Fiber Dual-Channel Atmospheric Greenhouse Gases Laser Heterodyne Detection Technology[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(02): 354-359. |
[12] |
SUN Ran, HAO Xiao-jian*, YANG Yan-wei, REN Long. Effect of Cavity Confinement Materials on Laser-Induced Breakdown Cu Plasma Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3801-3805. |
[13] |
KONG Dan-dan, HAN Tong-shuai, GE Qing, CHEN Wen-liang, LIU Rong, LI Chen-xi, XU Ke-xin*. Verification of Signal Extraction Capability of Near-Infrared Non-Invasive Blood Glucose Detection System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3438-3442. |
[14] |
GE Qing, HAN Tong-shuai*, LIU Rong, LI Chen-xi, XU Ke-xin. Temperature Correction of NIR Reflectance Spectrum of Noninvasive Blood Glucose Measurement Based on EPO[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(05): 1483-1488. |
[15] |
ZHENG Guo-liang, ZHU Hong-qiu*, LI Yong-gang. Spectral Signal Denoising Algorithm Based on Improved LMS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(02): 643-649. |
|
|
|
|