光谱学与光谱分析 |
|
|
|
|
|
A Method of Precise Adjustment and Calibration for High-Resolution Echelle Spectrograph |
CHEN Shao-jie1,2, CUI Ji-cheng1,2, LIU Yu-juan1,2, Bayanheshig1, TANG Yu-guo1 |
1. Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China 2. Graduate University of Chinese Academy of Sciences, Beijing 100049, China |
|
|
Abstract Echelle spectrograph is a new type of high-resolution, high-precise spectrograph, and its resolution can be up to tens of thousands to hundreds of thousands. In this case, a little error of the structure will affect the resolution and precision greatly, so an accurate adjustment is of importance for the echelle spectrograph. According to the design features, the present paper discusses the adjustment method for echelle spectrograph. This is an uncomplicated, quick method, and adapts to mini, airproof structure of echelle spectrograph. Using this method, the actual state is consistent with the design result. The result of wavelength calibration is given out, and the error is less than 0.002 nm, which satisfies the requirement of the system.
|
Received: 2011-12-07
Accepted: 2012-02-28
|
|
Corresponding Authors:
CHEN Shao-jie
E-mail: shaojie.csj@gmail.com
|
|
[1] Xu Lina, Davonport Mark A, et al. SPIE, 2011, 8165:81650E1. [2] Tousey R, Purcell J D, Garrett D L. Applied Opitcs, 1967, 6(3):365. [3] Koch J, Okruss M, Franzke J, et al. Spectrochimica Acta,Part B, 2004, 59:199. [4] Florek S, Haisch C, Okruss M, et al. Spectrochimica Acta,Part B,2001, 56:1027. [5] LI Na-na, AN Zhi-yong, CUI Ji-chang(李娜娜,安志勇,崔继承). Opt. Precision Eng.(光学精密工程), 2009, 17(3):531. [6] Frank Grupp, Shaoming Hu, Liang Wang. Proc. of SPIE,2009, 7440:7440G. [7] Frank Grupp, Thomas Udem, et al. Proc. of SPIE, 2010, 7735: 7735731. [8] TANG Yu-guo, SONG Nan, Bayanheshig, et al(唐玉国,宋 楠,巴音贺希格,等). Opt. Precision Eng.(光学精密工程), 2010, 18(9):1989. [9] LIANG Pei(梁 培). Acta Optica Sinica(光学学报), 2006, 26(6):909. [10] SHI Hong-bin, CHENG Zhao-gu, XU Guo-liang, et al(石鸿斌,程兆谷,许国良,等). Chinese Journal of Lasers(中国激光), 2000, 27(10):880. [11] LIU Jian-feng, LONG Fu-nian, ZHANG Wei(刘剑峰,龙夫年,张 伟). Optical Technique(光学技术), 2004, 30(5):571. [12] Bayanheshig, QI Xiang-dong, TANG Yu-guo(巴音贺希格,齐向东,唐玉国). Acta Physica Sinica(物理学报), 2003,52(5):1157. [13] Bayanheshig(巴音贺希格). Acta Physica Sinica(物理学报),2004,53(7):2118. [14] ZHANG Shan-wen, Bayanheshig(张善文,巴音贺希格). Opt. Precision Eng.(光学精密工程), 2009,17(5):990. [15] TANG Yu-guo, CHEN Shao-jie, Bayanheshig, et al(唐玉国,陈少杰,巴音贺希格,等). Opt. Precision Eng.(光学精密工程), 2010, 18(10):2130. [16] Piskunov N E. Astronomy & Astrophysic, 2002,385:1095. [17] Jean-Francois Lavigne, Michel Doucet, Min Wang, et al. SPIE, 2011, 7735:7735391. |
[1] |
YAO Li-ming1, 2, ZHANG Ling3*, XU Zong4, 5, YANG Xiu-da6, WU Cheng-rui6, ZHANG Rui-rui3, YANG Fei3, WU Zhen-wei3, YAO Jian-ming3, GONG Xian-zu3, HU Li-qun3. In-Situ Wavelength Calibration of Fast-Response Extreme Ultraviolet Spectrometers on Experimental Advanced Superconducting Tokamak and Its Application[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(08): 2645-2650. |
[2] |
ZHANG Rui1,2, ZHU Ji-wei1, LIU Jian-li1,2, CUI Ji-cheng1, LI Xiao-tian1, Bayanheshig1. Study on the Laser-Induced Plasma Spectroscopy Based on the Echelle Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(05): 1605-1609. |
[3] |
SHEN Chun-yang1, 2, CUI Ji-cheng1*, SUN Ci1, WANG Wei1, 2, CHEN Jian-jun1, 2, LI Xiao-tian1. A Detection System Design of Echelle Diffraction Efficiency and Stray Coefficient[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2603-2609. |
[4] |
HUANG Yuan-shen1, 2, DONG Cheng-cheng1, 2*, HUANG Yun-bai1, 2, SHENG Bin1, 2, ZHOU Hong-yan1, 2, SUN Le1, 2, YANG Hai-ma1, 2, ZHANG Da-wei1, 2 . Research on Straightness Error Compensation of Grating Ruling Machine [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(03): 946-951. |
[5] |
YIN Lu1, 2,Bayanheshig1*,YAO Xue-feng1,CUI Ji-cheng1,ZHU Ji-wei1,ZHANG Rui1, 2. Algorithm for Background Removal in Spectral Image of Echelle Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(06): 1925-1929. |
[6] |
YIN Lu1, 2, Bayanheshig1*, CUI Ji-cheng1, YANG Jin1, 2, ZHU Ji-wei1, YAO Xue-feng1 . An Effective Wavelength Detection Method Based on Echelle Spectra Reduction [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(03): 850-855. |
[7] |
ZHANG Yin-xin1, YANG Huai-dong2, DENG Chao1, HUANG Zhan-hua1, JIN Guo-fan2 . Optical Design of High-Resolution Echelle-Prism Cross-Dispersion [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(06): 1706-1710. |
[8] |
GE Xian-ying, CHEN Si-ying*, ZHANG Yin-chao, CHEN He, GUO Pan, BU Zhi-chao, CHEN Sheng-zhe . The Echelle Grating Monochromator’s Design of Pure Rotational Raman Lidar [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(02): 567-570. |
[9] |
NING Chun-li1, 2, QI Xiang-dong1, CHEN Shao-jie1, 2, Bayanheshig1, CUI Ji-cheng1, 2 . Optical Design and Performance Analysis of Light and Small Echelle Spectrograph[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(12): 3406-3410. |
[10] |
HE Miao1,2, TANG Yu-guo1*, CHEN Shao-jie1,2, Bayanheshig1, CUI Ji-cheng1,2 . Position Acquiring of Signal Spots in the Echelle Spectrograph[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(03): 849-853. |
[11] |
LIU Yu, LIU Wen-qing*, KAN Rui-feng, SI Fu-qi, XU Zhen-yu, HU Ren-zhi, XIE Pin-hua . Measurement of OH Radicals in Flame with High Resolution Differential Optical Absorption Spectroscopy [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(10): 2659-2663. |
[12] |
JIANG Jie1,HUAN Yan-fu1,JIN Wei2,FENG Guo-dong1,FEI Qiang1,CAO Yan-bo1,JIN Qin-han1,2* . Development of a High Resolution Simultaneous Microwave Plasma Torch Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(11): 2375-2379. |
|
|
|
|