光谱学与光谱分析 |
|
|
|
|
|
Geometric Distortion Correction for Hyperspectral Image Using a Rotating Scan Reflector |
KE Gang-yang1, AN Ning1, TIAN Yang-chao1, MA Zhi-hong2, HUANG Wen-jiang2, WANG Qiu-ping1* |
1. National Synchrotron Radiation Laboratory, University of Science and Technology of China,Hefei 230029, China 2. National Engineering Research Center for Information Technology in Agriculture, Beijing Academy of Agricultural and Forestry Sciences, Beijing 100097, China |
|
|
Abstract Offner imaging spectrometer is a kind of pushbroom imaging system. Hyperspectral images acquired by Offner imaging spectrometers require relative motion of sensor and scene that is translation or rotation. Via rotating scan with a reflector at the front of sensor’s len, large objects can be entirely captured. But for the changes in object distances, geometric distortion occurs. A formula of space projection from an object point to an image point by one capture was derived. According to the projection relation and slit’s motion curve, the object points’ coordinates on a reference plan were obtained with rotation angle for a variable. A rotating scan device using a reflector was designed and installed on an Offner imaging spectrometer. Clear images were achieved from the processing of correction algorithm.
|
Received: 2012-02-14
Accepted: 2012-04-10
|
|
Corresponding Authors:
WANG Qiu-ping
E-mail: qiuping@mail.ustc.edu.cn
|
|
[1] Marcus W A, Legleiter C J, Aspinall R J, et al. Geomorphology, 2003, 55(1-4): 363. [2] Qin J W, Burks T F, Ritenour M A, et al. Journal of Food Engineering, 2009, 93(2): 183. [3] Hinnrichs M, Piatek B. Proc. SPIE, 2004, (10):5270. [4] Lee Z P, Carder K L, Chen R F. Journal of Geophysical Research, 2001, 106(C6): 11639. [5] Johnson W R, Wilson D W, Fink W, et al. Journal of Biomedical Optics, 2007, 12(1): 114036. [6] Oertel D, Zhukov B, Thamm H P, et al. International Journal of Remote Sensing, 2004, 25(11): 2209. [7] ZHOU Quan, WU Gang, WANG Qiu-ping, et al(周 全,吴 刚,王秋平,等). Proceedings of the 29th Chinese Control Conference(第29届中国控制会议), 2010. [8] ZHOU Quan, ZHU Da-zhou, WANG Cheng,et al(周 全,朱大洲,王 成,等). Food Science(食品科学),2010, 31(23): 423. [9] HUANG Wen-jiang, ZHANG Dong-yan, MA Zhi-hong, et al(黄文江,张东彦,马智宏,等). Proceedings of the 8th Technology and Application of Imaging Spectroscopy(第八届成像光谱技术与应用研讨会暨交叉学科论坛文集),2010. [10] HUANG Wen-jiang, WANG Qiu-ping, MA Zhi-hong, et al(黄文江,王秋平,马智宏,等). Proceedings of the 8th Technology and Application of Imaging Spectroscopy(第七届成像光谱技术与应用研讨会论文集),2009. [11] DING Na, GAO Jiao-bo, WANG Jun, et al(丁 娜,高教波,王 军,等). Journal of Applied Optics(应用光学),2010,31(1): 65. [12] FAN Shi-fu, XIAO Song-shan, ZHAO You-quan, et al(范世福,肖松山,赵友全,等). Modern Scientific Instruments(现代科学仪器),2005,(1): 60. [13] TONG Ya-jun, WU Gang, ZHOU Quan, et al(佟亚军,吴 刚,周 全,等). Acta Optica Sinica(光学学报),2010,30(4): 1148. [14] WU Zhen-zhou, DU Xue-wei, LI Chao-yang, et al(吴振洲, 杜学维, 李朝阳,等). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2011, 31(10): 2647. [15] Scheibe K, Korsitzky H, Reulke R, et al. Int. Workshop Robot Vision, Auckland,2001. 77.
|
[1] |
LI Xin-quan1, 2,ZHANG Jun-qiang1, 3*,WU Cong-jun1,MA Jian1, 2,LU Tian-jiao1, 2,YANG Bin3. Optical Design of Airborne Large Field of View Wide Band Polarization Spectral Imaging System Based on PSIM[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 250-257. |
[2] |
LI Ming, QIN Kai*, ZHAO Ning-bo, TIAN Feng, ZHAO Ying-jun. Study on the Relationship Between Black Soil Emissivity Spectrum and Total Potassium Content Based on TASI Thermal Infrared Data[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2862-2868. |
[3] |
LIU Jia-nan1, 2*, CUI Ji-cheng1, YIN Lu1, 2, SUN Ci1, CHEN Jian-jun1, 2, ZHANG Rui1, 2, LIU Jian-li1, 2. Analysis and Design of Pre-Imaging System of Integral Field Imaging Spectrometer Based on Lenslet Array[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3269-3272. |
[4] |
ZHAO Shou-jiang1, YANG Bin1, JIAO Jian-nan2, YANG Peng1, WU Tai-xia3*, WANG Xue-qi1, YAN Lei1*. Using a Polarization Method to Reduce the Vegetation Inversion Error Caused by Strong or Weak Reflection Intensity[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3315-3320. |
[5] |
ZHANG Quan1, 2, HUANG Shu-hua1*, TIAN Yu-ze1, 2, LU Yue-lin1, 2, ZHAO Min-jie1, ZHOU Hai-jin1, ZHAO Xin1, WANG Yu1, SI Fu-qi1. Noise Analysis and Processing Method of Environment Monitoring Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(09): 2976-2981. |
[6] |
LIU Xiang-lei1,2, LIU Yang-yang1*, FANG Yu1, PEI Lin-lin1, Lü Qun-bo1. Optical Design of Large Relief Large Relative Apertureand High Resolution Modified Dyson Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3908-3912. |
[7] |
GAO Jian-hua1,2, LIANG Jing-qiu1, Lü Jin-guang1*, LIANG Zhong-zhu1, QIN Yu-xin1, WANG Wei-biao1. A Stepped Mirror Based Temporally and Spatially Modulated Imaging Fourier Transform Spectrometer: Principle and Data Processing[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3932-3939. |
[8] |
LI Shi-wei1,2, WANG Zhao-ba1,2, ZHANG Rui1,2,WANG Zhi-bin1,2,3. Spectral Measurements Based on Difference Frequency Modulation of Two PEMs Modulators[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2966-2973. |
[9] |
ZHENG Zhi-zhong1,2, YANG Zhong1*, XIU Lian-cun2, DONG Jin-xin2, CHEN Chun-xia2, GAO Yang2, YU Zheng-kui2. Design of a SWIR Offner Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2267-2272. |
[10] |
MAO Jing-hua1, 2, WANG Yong-mei1,2*, SHI En-tao1, ZHANG Zhong-mou1, JIANG Fang1. Study on the Slitfunction Test Method Based on Hyperspectral Imaging Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(04): 1286-1290. |
[11] |
PEI Lin-lin1, XIANGLI Bin1, 2, LIU Yang-yang2*, Lü Qun-bo2, SHAO Xiao-peng1 . The Snapshot Imaging Spectrometer with Image Replication Based on Wallaston Prism[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4105-4112. |
[12] |
LIU Yu-juan1, WANG Cheng-ming1, LIN Jun1*, CUI Ji-cheng2, ZHANG Tian-yu1*, ZHONG Zhi-cheng1* . Optimal Design of Light Folding Imaging Spectrometer Based on Dyson Concentric System [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2287-2290. |
[13] |
LIU Bing1, 2, LIU Ying1, ZHANG Xiao-long3, LI Can1, WANG Jian1, LI Chun1*, SUN Qiang1. Study on Coaxial Linear Dispersion Triplet Prisms of Wide Spectral Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1543-1548. |
[14] |
Lü Jin-guang1, LIANG Jing-qiu1, LIANG Zhong-zhu1*, TIAN Chao1, 2, QIN Yu-xin1. Analysis and Design of Interference Imaging System in Fourier Transform Imaging Spectrometer Based on Multi-Micro-Mirror[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1554-1559. |
[15] |
XIE Pei-yue1, 2, YANG Jian-feng1, XUE Bin1*, Lü Juan1, HE Ying-hong1, LI Ting1, MA Xiao-long1 . Research on an Equal Wavelength Spectrum Reconstruction Method of Interference Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 848-852. |
|
|
|
|