光谱学与光谱分析 |
|
|
|
|
|
A Solar Blind Light Source with Long Dynamic Range |
ZHOU Yue1, YAN Feng1*, ZHANG Ming-chao1, GAO Song-tao1, 2 |
1. State Key Lab of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China 2. Graduate University of Chinese Academy of Sciences, Beijing 100049, China |
|
|
Abstract In order to realize the irradiance calibration of SBUV-ICCD (solar blind ultraviolent Intensified change-coupled device) with dynamic range reaching 120 dB, a light source with long dynamic range was designed and realized. Firstly, the irradiance dynamic range was estimated. Then using deuterium lamp, integrating sphere, precise stop and rail, an ultraviolent light source was developed, which has fixed structure of spectrum, but the irradiance can change continuously in long range. At last the light source’s performance was tested. The result shows that the irradiance between 0.278 and 2.8×10-7 μW·cm-2 was covered, and the stability was 0.93%/3 h. So the demand of calibration of irradiance was satisfied. It will help for measuring the surface uniformity of detector and the calibration of imaging systems.
|
Received: 2011-12-23
Accepted: 2012-03-18
|
|
Corresponding Authors:
YAN Feng
E-mail: yan.feng@126.com
|
|
[1] Paul Schreiber, Tuoc Dang, Thad Pickenpaugh, et al. SPIE, 1999, 3629: 230. [2] Malka Lindner, Shimon Elstein, Joseph Wallace. SPIE, 1998, 3302: 176. [3] Filip Neele, Ric Schleijpen. SPIE, 2003, 5075: 270. [4] LAN Tian, NI Guo-qiang(蓝 天,倪国强). Transactions of Beijing Institute of Technology(北京理工大学学报),2003, 23(8):419. [5] YAN Feng, YU Zi-jiang, YU Xiao, et al(闫 丰,于子江,于 晓,等). Optics and Precision Engineering(光学精密工程),2006, 14(4):709. [6] ZHANG Jian-yong, ZHONG Sheng-dong(张建勇,钟生东). Optical Technique(光学技术),2000, 26(4): 308. [7] David Dussault and Paul Hoess. SPIE 2004, 5563: 195. [8] Malka Lindner, Shimon Elstein, Pinhas Lindner. SPIE, 1998, 3434: 22. [9] ZHAO Yu-huan, YAN Feng, ZHOU Yue, et al(赵玉环,闫 丰,周 跃,等). Optics and Precision Engineering(光学精密工程),2008, 16(9):1572. [10] Kim Fowler. IEEE Transactions on Instrumentation and Measurement, 2004, 53(4): 1057. [11] ZHOU Yue, YAN Feng, GU Yong-qiang, et al(周 跃,闫 丰,谷勇强,等). Optics and Precision Engineering(光学精密工程),2009, 17(11):2712. [12] JIN Wei-qi, HE Yu-qing, WANG Ling-xue, et al(金伟其,何玉清,王岭雪,等). Acta Aamamentraii(兵工学报),2001,22(1): 48. [13] Tania Konry, Mounic Bouhifd, Serge Cosnier, et al. Biosensors and Bioelectronics, 2007, 22(9):2230. [14] Privalova A I, Morozova Ju P, Kashapova E R, et al. Journal of Applied Spectroscopy, 2011, 78(3):309. [15] David G Goebel. Applied Optics, 1967, 6(1):125. [16] CHE Nian-zeng, YAN Da-yuan(车念曾,阎达远). Radiometry and Photometry(辐射度学和光度学). Beijing: Beijing Institute of Technology Press(北京:北京理工大学出版社),1990.
|
|
|
|