光谱学与光谱分析 |
|
|
|
|
|
Preconcentration of Ultra-Trace Germanium in Water Samples with Nano-Sized TiO2 Colloid and Determination by HGAFS with Colloid Sampling |
QIAN Sha-hua, LU Min, ZHANG Xu |
School of Resources and Environmental Science, Hubei Biomass-Resource Chemistry and Environmental Biotechnology Key Laboratory, Wuhan University, Wuhan 430079, China |
|
|
Abstract A novel method for preconcentration of ultra-trace germanium and determination by hydride generation atomic fluorescence spectrometry (HGAFS) was presented in this work. When the pH values of solution were 6.0~8.0, the adsorption efficiency of nano-sized TiO2 colloid for germanium was 97.0%~99.0% in a short time. Nano-sized TiO2 colloid was used to concentrate the ultra-trace germanium in water sample due to its high absorption capacity. After centrifugation, the supernatant fluid was removed. The sediment which contained the concentrated Ge(Ⅳ) was inverted to colloid by adding HCl of certain concentration. Ge(Ⅳ) in colloid was directly determined by HGAFS. The proposed method possesses low detection limit (3σ) (0.060 μg·L-1) and good precision (the relative standard deviation (RSD) is 2.0%, n=6). The method is was also quite simple and time saving (without any filtration and desorption process). Satisfactory results were obtained when applying this method to the determination of ultra-trace germanium in water samples.
|
Received: 2011-11-24
Accepted: 2012-02-16
|
|
Corresponding Authors:
QIAN Sha-hua
E-mail: qiansh@whu.edu.cn
|
|
[1] Sutton J, Ellwood M J, Maher W A, et al. Global Biogeochemical Cycles, 2010, 24: GB2017-1-13. [2] Lugolobi F, Kurtz A C, Derry L A. Geochimica et Cosmochimica Acta, 2010, 74: 1294. [3] ZHANG Hong-li, WEI Jian-jun(张洪利,魏建军). Water & Wastewater Engineering(给水排水), 2006, 32(10): 46. [4] LI Xiang-xin, GONG Qi(李向欣,龚 琦). Physical Testing and Chemical Analysis(Part B: Chemical Analysis(理化检验·化学分册), 2008, 44(9): 864. [5] Shi Jianbo, Tang Zhiyong, Tan Chunhua, et al. Talanta, 2002, 56(4): 711. [6] LI Dan, LI Biao(李 丹,李 彪). Metallurgical Analysis(冶金分析), 2010, 30(12): 33. [7] QIAN Sha-hua, WEI Jin-bao(钱沙华,韦进宝). Environmental Instrument Ananlysis, Second Edition.(环境仪器分析,第2版). Beijing: China Environmental Science Press(北京:中国环境科学出版社),2011. [8] Gktürk G, Delzendeh M, Volkan M. Spectrochimica Acta Part B, 2000, 55(7): 1063. [9] Qian Shahua, Huang Zhen, Fu Jiaqi, et al. Analytical Method, 2010, 2(8): 1140. [10] Qian Shahua, Zhang Sijing, Huang Zhen, et al. Microchimica Acta, 2009, 166(3): 251. [11] Afkhami A, Saber-Tehrani M, Bagheri H, et al. Microchimica Acta, 2011, 172: 125. [12] Kalfa O M, Yalcnkaya , Türker A R. Journal of Hazardous Materials, 2009, 166: 455. [13] He Q, Chang X, Huang X, et al. Microchimica Acta, 2008, 160: 147. [14] State Standard of the People’s Republic of China(中华人民共和国国家标准), GB/T8538—2008. Determination of Germanium in Natural Mineral Drinking Water by Hydride Generation Atomic Fluorescence Spectrometry(氢化物发生原子荧光法测定饮用天然矿泉水中锗).
|
[1] |
HUANG Rui1, LI Yu1, HE Wen-xuan1*, LU Xian-yong2, CHEN Wei-jian1, CHEN Ting1, ZHANG Yan-jie1. A Quick and Simple Method for Extracting Unsaponifiables of Vegetable Oil[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(06): 1852-1856. |
[2] |
HUANG Si-si, ZHANG Xu, QIAN Sha-hua* . Preconcentration of Trace Cu(Ⅱ) in Water Samples with Nano-Sized ZnO and Determination by GFAAS [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(09): 2420-2423. |
[3] |
PENG Hong1, ZHANG Xu2* . Preconcentration of Ultra-Trace As(Ⅲ) in Water Samples with Nano-Sized ZnO and Determination by HGAFS with Colloid Sampling[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(03): 822-825. |
[4] |
ZHANG Dong,SU Hui-dong,GAO Hong. Study on the Adsorption Capability of Barium-Strontium Titanate Powder Coated with Dithizone for Cadmium Ion in Water[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(03): 693-696. |
[5] |
XIAO Ming-fa,CHEN Shi-zhong*,LU Deng-bo,ZHAN Xi-lin. Determination of Gold in Geological Sample by Inductively Coupled Plasma Mass Spectrometry after Carbon Nanofibers Separation and Preconcentration [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(02): 444-446. |
[6] |
LIU Zheng-hua1,ZHOU Fang-qin1*,JIANG Fang-ming2,HUANG Rong-hui1,YANG Liu1,ZHOU Le-zhou1 . Determination of Trace Gold by Flame Atomic Absorption Spectrometry after Separation and Preconcentration with Load Nanometer Titanium Dioxide[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(02): 456-459. |
[7] |
MA Ge1,XIE Wen-bing2*,LIU Jing1,LI Xin-yang1,JIN Yan-wei1 . Speciation of Arsenic(Ⅲ) and Arsenic(Ⅴ) in Water by Hydride Generation Atomic Fluorescence Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(04): 807-809. |
[8] |
MA Hong-mei, ZHU Zhi-liang*,ZHANG Rong-hua, ZHAO Jian-fu . Separation of Cr(Ⅵ) and Organic Cr(Ⅲ) in Natural Water by Weak Basic Anion Exchange Resin and Determination by ICP-AES[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(01): 165-168. |
[9] |
SU Yao-dong, ZHU Wen-ying, MA Hong-mei, CHEN Long-wu. Determination of Trace Lead and Iron in Nickel Chloride and Manganese Sulfate by Flame Atomic Absorption Spectrometry after Coprecipitation with Yttrium Phosphate [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(09): 1732-1734. |
[10] |
SU Yao-dong, LI Jing, HUANG Yan, CHEN Long-wu. Application of Internal Standardization to Rapid Coprecipitation Technique Using APDC-Cu(Ⅱ) for FAAS Determination of Lead in Salt[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(03): 564-566. |
[11] |
HANG Yi-ping1,2, QIN Yong-chao1*, JIANG Zu-cheng1, HU Bin1 . Study on the Adsorption Behavior of Ga, In and Tl on Nanometer-Size Titanium Dioxide by ICP-AES [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(07): 1131-1134. |
[12] |
WEI Qin1, DU Bin1, WU Dan1, OU Qing-yu2 . Spectrophotometric Determination of Trace Amount of Copper with Trimethoxyphenylfluorone in Microemulsion after Preconcentration and Separation by Sulphydryl Dextran Gel[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(05): 772-775. |
[13] |
SHI Ta-qing1, LIANG Pei2*, LI Jing2, LU Han-bing2 . Nanometer-Size Titanium Dioxide Separation/Preconcentration and ICP-AES for the Determination of Cd, Co and Zn [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(03): 444-446. |
[14] |
WEI Qin1, DU Bin1, WU Dan1, OU Qing-yu2 . Spectrophotometric Determination of Tace Amount of Lead with Trimethoxyphenylfluorone in Microemulsion after Using Sulphydryl Dextran Gel for Preconcentration and Separation[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24(11): 1400-1403. |
|
|
|
|