光谱学与光谱分析 |
|
|
|
|
|
In-Flight Absolute Radiometric Calibration of UAV Hyperspectral Camera and Its Validation Analysis |
GOU Zhi-yang1,2, YAN Lei1,2*, CHEN Wei1,2, JING Xin1,2, YIN Zhong-yi1,2, DUAN Yi-ni1,2 |
1. Institute of RS & GIS, School of Earth and Space Science, Peking University, Beijing 100871, China 2. Beijing Key Lab of Spatial Information Integration & Its Applications, Peking University, Beijing 100871, China |
|
|
Abstract With the data in Urad Front Banner, Inner Mongolia on November 14th, 2010, hyper-spectral camera on UAV was calibrated adopting reflectance-based method. During the in-flight absolute radiometric calibration, 6 hyper-spectral radiometric gray-scale targets were arranged in the validation field. These targets’ reflectances are 4.5%, 20%, 30%, 40%, 50% and 60% separately. To validate the calibration result, four extra hyper-spectral targets with sharp-edge spectrum were arranged to simulate the reflection and absorption peaks in natural objectives. With these peaks, the apparent radiance calculated by radiation transfer model and that calculated through calibration coefficients are much different. The result shows that in the first 15 bands (blue bands), errors are somewhat huge due to the noises of equipment. In the rest bands with quite even spectrum, the errors are small, most of which are less than 10%. For those bands with sharp changes in spectral curves, the errors are quite considerable, varying from 10% to 25%.
|
Received: 2011-04-29
Accepted: 2011-07-29
|
|
Corresponding Authors:
YAN Lei
E-mail: lyan@pku.edu.cn
|
|
[1] Zhang Y, Li Y, Rong Z G, et al. Journal of Infrared and Millimeter Waves, 2009, 28(3): 188. [2] Kodama S, Ohtake M, Yokota Y, et al. Space Science Reviews, 2010, 154(1-4): 79. [3] Zhang L F, Zhang L P, Yan L, et al. Journal of Imaging Science and Technology, 2007, 51(2): 141. [4] TANG Hong-zhao, YAN Lei, LI Cheng-cai, et al(唐洪钊, 晏 磊, 李成才, 等). Geography and Geo-Information Science(地理与地理信息科学), 2010, 26(4): 12. [5] Chander G, Markham B L, Helder D L. Remote Sensing of Environment, 2009, 113(5): 893. [6] SONG Zong-xi, ZHAO Bao-chang, GAO Wei, et al(宋宗玺, 赵葆常, 高 伟,等). Acta Optica Sinica(光学学报), 2010, 30(12): 3508. [7] Darren T J, Arthur L F, Roger D. Canada Journal of Remote Sensing, 2006, 32(5): 330. [8] Lang J, Brooks D H, Lanzafame A C, et al. Astronomy & Astrophysics, 2007, 463(1): 339. [9] Slater P N, Biggar S F, Holm R G, et al. Remote Sensing of Environment, 1987, 22(1): 11. [10] Biggar S F, Thome K J, Wisniewski W. IEEE Transactions on Geoscience and Remote Sensing, 2003, 41(6): 1174. [11] Gu X F, Guyot G, Verbrugghe M. International Journal of Remote Sensing, 1992, 13(14): 2531. [12] Gu Y, Anderson J M, Monk J G C. International Journal of Remote Sensing, 1999, 20(3): 535. [13] ZHANG Yu-xiang, ZHANG Guang-shun, HUANG Yi-fen, et al(张玉香, 张广顺, 黄意玢,等). Acta Meteorologica Sinica(气象学报), 2002, 60(6): 740. [14] Biggar S F, Slater P N, Gellman D I. Remote Sensing of Environment, 1994, 48(2): 245. [15] Thome K J,Helder D L,Aaron D, et al. IEEE Transactions on Geoscience and Remote Sensing, 2004, 42(12): 2777. [16] Gao H L, Gu X F, Yu T, et al. Science China-Technological Sciences, 2010, 53(11): 3119.
|
[1] |
CUI Zhen-zhen1, 2, MA Chao1, ZHANG Hao2*, ZHANG Hong-wei3, LIANG Hu-jun3, QIU Wen2. Absolute Radiometric Calibration of Aerial Multispectral Camera Based on Multi-Scale Tarps[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3571-3581. |
[2] |
LIU Li-xi, CHEN Lin, CHEN Zhi-li*, TANG Jin, PENG Wu-di, HU Tian-you, WANG Hao-wen. Research on the Radiation Characteristics of Low-Carbon Chemical Flame Infrared Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 62-67. |
[3] |
LIU Jia-qing1, 2, LI Zhi-zeng1, 4, LI Jing3*, LIU Lei1, 4, LIU Lei1, GUO Hong-long1, WANG Jian-guo1. Phase Characterizing and Processing in Fourier Transform Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(11): 3328-3335. |
[4] |
FANG Chen-yan1, 2, 3, LI Qing-ling1, 2, 3, YU Jin-tao1, 2, 3, YIN Da-yi1, 2, 3*. The Measurement Study and Analysis of Ultraviolet Features of High Voltage Arc and Coronaindoors[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(04): 1178-1183. |
[5] |
WANG Jian-wei, PEI Lin-lin, TAN Zheng, HUANG Min*, Lü Qun-bo, LIU Yang-yang, LI Wei-yan. Study on the Relative Radiance Calibration Method of Large Array Filter-Type Multispectral Imaging System[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2615-2618. |
[6] |
CHEN Lin1, 2, XU Na1, 2, HU Xiu-qing1, 2*, LU Feng1, 2, ZHANG Peng1, 2 . Study on Orbit Radiometric Calibration for FY-2 Visible Band based on Deep Convective Cloud [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(08): 2639-2645. |
[7] |
YANG Jin1, 2, CUI Ji-cheng1, Bayanheshig1, QI Xiang-dong1, TANG Yu-guo1*, YAO Xue-feng1. Study on the Design of Prism Hyperspectral Imaging System Based on Off-Axis Two-Mirror Littrow Configuration[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1537-1542. |
[8] |
ZHENG Feng1, LIU Li-ying1, LIU Xiao-xi2, LI Ye1, SHI Xiao-guang1, ZHANG Guo-yu1, HUAN Ke-wei1* . VMTBB-Based Spectral Radiometric Calibration of NIR Fiber Coupled Spectrometer [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(09): 2665-2671. |
[9] |
HAN Jie1, 2, 3, XIE Yong1, 3*, GU Xing-fa1, 3, YU Tao1, 3, LIU Qi-yue1, 3, GAO Rong-jun1, 2, 3 . In-Flight Radiometric Calibration for ZY-3 Satellite Multispectral Sensor by Modified Reflectance-Based Method [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(03): 856-861. |
[10] |
LI Zhi-gang, ZHENG Yu-quan . Laser-Based Radiometric Calibration [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(12): 3424-3428. |
[11] |
XU Na1, 2, HU Xiu-qing1, 2*, CHEN Lin1, 2, ZHANG Yong1, 2 , HU Ju-yang1, 2, SUN Ling1, 2 . On-Orbit Radiometric Calibration Accuracy of FY-3A MERSI Thermal Infrared Channel[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(12): 3429-3434. |
[12] |
WANG Jian-wei1,2 , HUANG Min1, XIANGLI Bin1, TU Xiao-long1,2 . Study on the Characteristics of Radiance Calibration Using Nonuniformity Extended Source[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(07): 2002-2005. |
[13] |
YU Lei, LIN Guan-yu, CHEN Bin . Study on the Absolute Spectral Irradiation Calibration Method for Far Ultraviolet Spectrometer in Remote Sensing[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(01): 246-249. |
[14] |
CHEN Wei1, 2, 3, YAN Lei1, 2, 3*, GOU Zhi-yang1, 2, 3, ZHAO Hong-ying1, 2, 3, LIU Da-ping1, 2, 3, DUAN Yi-ni1, 2, 3 . In-Flight Absolute Radiometric Calibration of UAV Multispectral Sensor [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(12): 3169-3174. |
[15] |
DU Li-li1, 2, YI Wei-ning1, 2, ZHANG Dong-ying1, 2, HUANG Hong-lian1, 2, QIAO Yan-li1, 2, ZHANG Xie3 . Radiometric Calibration of LCTF-Based Multispectral Area CCD Camera [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(01): 272-276. |
|
|
|
|