光谱学与光谱分析 |
|
|
|
|
|
Photoionization Ion Mobility Spectrometry (UV-IMS) for the Isomeric Volatile Organic Compounds |
LI Hu1,3, NIU Wen-qi2, WANG Hong-mei1, HUANG Chao-qun1, JIANG Hai-he1, CHU Yan-nan1* |
1. Laboratory of Environmental Spectroscopy, Anhui Institute of Optics and Fine Mechanics, Center of Medical Physics and Technology, Hefei Institutes of Physics, Chinese Academy of Sciences, Hefei 230031, China 2. School of Science, Anhui Agricultural University, Hefei 230036, China 3. Anhui University of Science and Technology, Huainan 232001, China |
|
|
Abstract The construction and performance study is reported for a newly developed ultraviolet photoionization ion mobility spectrometry (UV-IMS). In the present paper, an UV-IMS technique was firstly developed to detect eleven isomeric volatile organic compounds including the differences in the structure of carbon chain, the style of function group and the position of function group. Their reduced mobility values were determined and increased in this order: linears<branches<cycles, primary<secondary<tertiary, para-<meta-<ortho- and alcohols <acetones<aromas. The concentrations of analytes were obtained by means of exponential dilution method, and the experiments show that the limit of detection of the homemade UV-IMS was around ppb-ppm.
|
Received: 2011-03-18
Accepted: 2011-07-05
|
|
Corresponding Authors:
CHU Yan-nan
E-mail: ychu@aiofm.ac.cn
|
|
[1] LI Zi-yao, WEI Jie, ZHANG Bing(李子尧, 魏 杰, 张 冰). Chinese Journal of Quantum Electronics(量子电子学报), 2001, 18(1): 1. [2] Steiner W E, Clowers B H, Matz L M, et al. Analytical Chemistry, 2002, 74(17): 4343. [3] Lawrence A H. Analytical Chemistry, 1989, 61(4): 343. [4] Eiceman G A, Preston D, Tiano G, et al. Talanta, 1997, 45(1): 57. [5] Han H Y, Wang H M, Jiang H H, et al. Chinese Journal of Chemical Physics, 2009, 22(6): 605. [6] Karpas Z, Pollevoy Y, Melloul S. Analytica Chimica Acta, 1991, 249(2): 503. [7] Karpas Z. Analytical Chemistry, 1989, 61(7): 684. [8] Borsdorf H, Neitsch K, Eiceman G A, et al. Talanta, 2009, 78(4-5): 1464. [9] Sielemann S, Baumbach J I, Schmidt H, et al. Analytica Chimica Acta, 2001, 431(2): 293. [10] Revercomb H E, Mason E A. Analytical Chemistry, 1975, 47(7): 970. [11] Bradbury N E, Nielsen R A. Physical Review, 1936, 49: 388. [12] Ritter J J, Adams N K. Analytical Chemistry, 1976, 48(3): 612. |
[1] |
GE Deng-yun, XU Min-min, YUAN Ya-xian*, YAO Jian-lin*. Surface-Enhanced Raman Spectroscopic Investigation on the Effect of
Solution pH on Dehydroxylation of Hydroxythiophenol Isomers[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(07): 2076-2081. |
[2] |
CHEN Geng-yin1, ZHANG Qi-hang1, LIU Yu-zhu1, 2*, ZHANGCHENG Yuan-zhe1, CHEN Yu1, CHEN Guo-qing1, HAN Bo-yuan1, ABULIMITI Bumaliya3*. Online Detection of VOCs Based on LIBS and Raman Spectra[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2729-2733. |
[3] |
ZHU Hai-jiang1, TANG Hao1, SUN Jing-xian1, DU Zhen-xia2. Classification Method of Liquor Quality Based on Time and Frequency Spectrum Characteristics[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2962-2968. |
[4] |
LÜ Xi-juan1, ZHANG Yun-hong2*. Observation of the Repartitioning of Malonic Acid in Levitated Malonic Acid/NaNO3/H2O Droplets by Optical Tweezers[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(10): 3098-3101. |
[5] |
ZHANG Gen-wei1, PENG Si-long2, 3, GUO Teng-xiao1,YANG Jie1, YANG Jun-chao1, ZHANG Xu1, CAO Shu-ya1*, HUANG Qi-bin1*. Ion Mobility Spectrometry Spectrum Reconstruction and Characteristic Peaks Extraction Algorithm Research[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2681-2685. |
[6] |
ZHANG Qiang1, 2, WEI Ru-yi1*, YAN Qiang-qiang1, ZHAO Yu-di1, ZHANG Xue-min1, YU Tao1. Application of Deep Neural Network in Quantitative Analysis of VOCs by Infrared Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(04): 1099-1106. |
[7] |
SHI Hai-xia1, XU Qing1, 2, WANG Han2, 3, LIU You-jiang2, LI Shan2, HU Jun2, 3, LI Yue1, 2*, CHEN Chi-lai2*. Study on the Effect of He-N2 Ratio in Mixed Carrier Gas on Separation of VOC Aliasing Peaks in FAIMS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39(09): 2713-2718. |
[8] |
WU Zhi-yuan1,YU Jian-wen1,2,LIU You-jiang1,CHEN Chi-lai1*. The Solution of Non-Linear Function of Ion Mobility Based on FAIMS Spectrum Peak Position[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(10): 3170-3174. |
[9] |
HUANG Li-juan, ZHANG Xin, WANG Guo, ZHANG Zhuo-yong*. Analysis of Leucine and Isoleucine for Low-Frequency Collective Absorption Spectrum Using Terahertz Time-Domain Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(08): 2462-2466. |
[10] |
YUE Bao-wang, DING Wei-jie . Detection System for VOCs Concentration Based on Improved Photo-Elastic Modulator[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(01): 232-235. |
[11] |
LIU Jian-wei, SHEN Jing-ling*, ZHANG Bo . Identification of Six Isomers of Dimethylbenzoic Acid by Using Terahertz Time-Domain Spectroscopy Technique [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(11): 3041-3045. |
[12] |
XIAO Yuan-fang, HE Miao-hong, ZHANG Shu-di, HANG Wei* . Mass Spectrometric Methods for Colorative Mechanism Analysis of Yaozhou Porcelain Glaze [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35(09): 2444-2449. |
[13] |
YIN Dan-dan1, WU Jing1*, XIE Chao-bo1, CAO Zhi-ping1, Lü Qing2, ZHANG Ren-quan2 . Comparison of Three-Dimensional Fluorescence Characteristics of Two Isomers:Phenanthrene and Anthrancene[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(12): 3263-3268. |
[14] |
LIU Sheng1, 2, HUANG Chao-qun1, 3, SHEN Cheng-yin1, 3, CHU Yan-nan1, 3* . Asymmetric Control Method for Ion Shutter and the Resolution Improvement of Ion Mobility Spectrum[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33(11): 2881-2885. |
[15] |
LI Hu1,3, HAN Hai-yan1, NIU Wen-qi2, WANG Hong-mei1, HUANG Chao-qun1, JIANG Hai-he1, CHU Yan-nan1* . Rapid Detection of Residual Cyclohexanone in Disposable Medical Devices by Ultraviolet Photoionization Ion Mobility Spectrometry (UV-IMS) [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(01): 46-49. |
|
|
|
|