光谱学与光谱分析 |
|
|
|
|
|
Study on the Characteristics of the Imaging Spectrometer Calibration Using Diffuser Method |
ZHANG Chun-lei1,2,XIANG Yang1* |
1. State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China 2. Graduate University of Chinese Academy of Sciences, Beijing 100049, China |
|
|
Abstract Using a white diffuser to calibrate the imaging spectrometer has been a new technology developed to calibrate the imaging spectrometer recently. It has characteristics of easy realization and higher calibration accuracy. The expression of the collected signal electron number in each spectral channel of the imaging spectrometer detector pixels was deduced with the slit parallel and perpendicular to the meridional plane according to the principal of the calibration of imaging spectrometer using diffuser method in the present paper. The spectral radiometric calibration characteristics of the imaging spectrometer was numerically analyzed under the two special slit directions. The results indicate that the slit direction has significant effect on the spectral radiometric calibration of the imaging spectrometer. The signal electron number of the same spectral channel collected by the different scene pixels is different when the slit parallels to the meridional plane, and when the pixel is closer to the standard lamp, it collects more signal electrons;the signal electron number of the same spectral channel collected by the different scene pixels doesn’t change with the scene pixel position when the slit is perpendicular to the meridional plane.
|
Received: 2010-03-29
Accepted: 2010-06-20
|
|
Corresponding Authors:
XIANG Yang
E-mail: xiangy@sklao.ac.cn
|
|
[1] CUI Dun-jie(崔敦杰). Remote Sensing Technology and Application(遥感技术与应用),1996,11(3): 56. [2] LI Zhao-zhou, ZHENG Xiao-bing, TANG Ling-li(李照洲,郑晓兵,唐伶俐). Journal of Remote Sensing(遥感学报), 2007,11(4): 581. [3] Chrien T G, Green R O, Eastwood M L. SPIE, 1990, 1298: 37. [4] Zadnika J, Guerina D, Moss R, et al. SPIE, 2001,5425: 182. [5] Barnes R A, Eplee R E, Schmidt M, et al. Applied Optics, 2001, 40(36): 6682. [6] Davis C O, Kappus M, Bowles J, et al. SPIE, 1999, 3753: 160. [7] Davis C O, Bowles J, Leathers R A, et al. Optics Express, 2002, 10(4): 210. [8] Zhou Jiankang, JI Yiqun, Chen Yuheng, et al. SPIE, 2009, 7506: M1. [9] YANG Hua-yuan, CUI Dun-jie, REN Jian-wei(杨华元,崔敦杰, 任建伟). Acta Metrologica Sinica(计量学报),1998, 19(2): 123. [10] Folkman M, Peariman J, Liao L et al. SPIE, 2001, 4151: 40. [11] LI Tong-ji, CHEN Qing-lian(李铜基,陈清莲). Ocean Technology(海洋技术),2001,20(4): 26. [12] Jarecke P, Yokoyama K. SPIE, 2004, 4135: 254.
|
[1] |
LI Xin-quan1, 2,ZHANG Jun-qiang1, 3*,WU Cong-jun1,MA Jian1, 2,LU Tian-jiao1, 2,YANG Bin3. Optical Design of Airborne Large Field of View Wide Band Polarization Spectral Imaging System Based on PSIM[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44(01): 250-257. |
[2] |
LI Ming, QIN Kai*, ZHAO Ning-bo, TIAN Feng, ZHAO Ying-jun. Study on the Relationship Between Black Soil Emissivity Spectrum and Total Potassium Content Based on TASI Thermal Infrared Data[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(09): 2862-2868. |
[3] |
LIU Jia-nan1, 2*, CUI Ji-cheng1, YIN Lu1, 2, SUN Ci1, CHEN Jian-jun1, 2, ZHANG Rui1, 2, LIU Jian-li1, 2. Analysis and Design of Pre-Imaging System of Integral Field Imaging Spectrometer Based on Lenslet Array[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3269-3272. |
[4] |
ZHAO Shou-jiang1, YANG Bin1, JIAO Jian-nan2, YANG Peng1, WU Tai-xia3*, WANG Xue-qi1, YAN Lei1*. Using a Polarization Method to Reduce the Vegetation Inversion Error Caused by Strong or Weak Reflection Intensity[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(10): 3315-3320. |
[5] |
ZHANG Quan1, 2, HUANG Shu-hua1*, TIAN Yu-ze1, 2, LU Yue-lin1, 2, ZHAO Min-jie1, ZHOU Hai-jin1, ZHAO Xin1, WANG Yu1, SI Fu-qi1. Noise Analysis and Processing Method of Environment Monitoring Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(09): 2976-2981. |
[6] |
CHANG Zhen1, 2, ZHAO Min-jie1*, WANG Yu1, SI Fu-qi1, ZHOU Hai-jin1, LIU Wen-qing1. Study on the Spectral Features of Space-Borne Aluminum Diffuser[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38(04): 997-1000. |
[7] |
LIU Xiang-lei1,2, LIU Yang-yang1*, FANG Yu1, PEI Lin-lin1, Lü Qun-bo1. Optical Design of Large Relief Large Relative Apertureand High Resolution Modified Dyson Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3908-3912. |
[8] |
GAO Jian-hua1,2, LIANG Jing-qiu1, Lü Jin-guang1*, LIANG Zhong-zhu1, QIN Yu-xin1, WANG Wei-biao1. A Stepped Mirror Based Temporally and Spatially Modulated Imaging Fourier Transform Spectrometer: Principle and Data Processing[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(12): 3932-3939. |
[9] |
LI Shi-wei1,2, WANG Zhao-ba1,2, ZHANG Rui1,2,WANG Zhi-bin1,2,3. Spectral Measurements Based on Difference Frequency Modulation of Two PEMs Modulators[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(09): 2966-2973. |
[10] |
ZHENG Zhi-zhong1,2, YANG Zhong1*, XIU Lian-cun2, DONG Jin-xin2, CHEN Chun-xia2, GAO Yang2, YU Zheng-kui2. Design of a SWIR Offner Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(07): 2267-2272. |
[11] |
MAO Jing-hua1, 2, WANG Yong-mei1,2*, SHI En-tao1, ZHANG Zhong-mou1, JIANG Fang1. Study on the Slitfunction Test Method Based on Hyperspectral Imaging Instrument[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(04): 1286-1290. |
[12] |
PEI Lin-lin1, XIANGLI Bin1, 2, LIU Yang-yang2*, Lü Qun-bo2, SHAO Xiao-peng1 . The Snapshot Imaging Spectrometer with Image Replication Based on Wallaston Prism[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4105-4112. |
[13] |
LIU Yu-juan1, WANG Cheng-ming1, LIN Jun1*, CUI Ji-cheng2, ZHANG Tian-yu1*, ZHONG Zhi-cheng1* . Optimal Design of Light Folding Imaging Spectrometer Based on Dyson Concentric System [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(07): 2287-2290. |
[14] |
LIU Bing1, 2, LIU Ying1, ZHANG Xiao-long3, LI Can1, WANG Jian1, LI Chun1*, SUN Qiang1. Study on Coaxial Linear Dispersion Triplet Prisms of Wide Spectral Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1543-1548. |
[15] |
Lü Jin-guang1, LIANG Jing-qiu1, LIANG Zhong-zhu1*, TIAN Chao1, 2, QIN Yu-xin1. Analysis and Design of Interference Imaging System in Fourier Transform Imaging Spectrometer Based on Multi-Micro-Mirror[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(05): 1554-1559. |
|
|
|
|