光谱学与光谱分析 |
|
|
|
|
|
Techniques for Pixel Response Nonuniformity Correction of CCD in Interferential Imaging Spectrometer |
YAO Tao1,4, YIN Shi-min2, XIANGLI Bin3,Lü Qun-bo4 |
1. Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710068, China 2. First Field of Trial and Training Air Base of the Chinese People’s Liberation Army, Jiuquan 735018, China 3. Academy of Optoelectronics, Chinese Academy of Sciences, Beijing 100190, China 4. Graduate University of Chinese Academy of Sciences, Beijing 100049, China |
|
|
Abstract Based on in-depth analysis of the relative radiation scaling theorem and acquired scaling data of pixel response nonuniformity correction of CCD (charge-coupled device) in spaceborne visible interferential imaging spectrometer, a pixel response nonuniformity correction method of CCD adapted to visible and infrared interferential imaging spectrometer system was studied out, and it availably resolved the engineering technical problem of nonuniformity correction in detector arrays for interferential imaging spectrometer system. The quantitative impact of CCD nonuniformity on interferogram correction and recovery spectrum accuracy was given simultaneously. Furthermore, an improved method with calibration and nonuniformity correction done after the instrument is successfully assembled was proposed. The method can save time and manpower. It can correct nonuniformity caused by other reasons in spectrometer system besides CCD itself’s nonuniformity, can acquire recalibration data when working environment is changed, and can also more effectively improve the nonuniformity calibration accuracy of interferential imaging spectrometer system.
|
Received: 2009-06-01
Accepted: 2009-09-06
|
|
Corresponding Authors:
YAO Tao
E-mail: yinshimin@yahoo.com.cn
|
|
[1] Inoue T, Iltoh K, Jchioka Y. Optics Letters, 1991, 18(12): 934. [2] Breckinridge J B, SPIE, 1996, 2819: 2. [3] XIANGLI Bin, YUAN Yan(相里斌, 袁 艳). Acta Photonica Sinica(光子学报), 2006, 35(12): 1869. [4] YE Song, XIONG Wei, QIAO Yan-li, et al(叶 松, 熊 伟, 乔延利, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2009, 29(3): 848. [5] LIN Ling, ZHANG Tai-shi, REN Zhao, et al(林 凌, 张泰石,任 钊, 等). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2008, 28(10): 2243. [6] Schulz M, Caldwell L. SPIE, 1995, 2470: 200. [7] DONG Zhen-shi,LIU Xiao-bo(董珍时, 刘小波). Laser & Infrared(激光与红外),2003, 33(3): 208. [8] YIN Shi-min, HONG Xin-hua, LIU Shang-qian, et al(殷世民, 洪新华, 刘上乾, 等). Journal of Infrared and Millimeter Waves(红外与毫米波学报), 2004, 23(1): 33. [9] HU Xiao-mei(胡晓梅). Infrared and Laser Engineering(红外与激光工程). 1999, 28(3): 9. [10] DAI Shao-sheng,ZHANG Tian-qi(代少升,张天骐). Optics and Precision Engineering(光学精密工程),2008, 16(4): 714. [11] Mooney J M,Shepherd F D, Ewing W S. Optical Engineering, 1989, 28(11): 1151. [12] Menzel W P, Smith W L, Herman L D. Appl. Opt., 1981, 20: 3641. [13] Gross W,Hierl T,Schuh M. Optical Engineering,1999,38(5):862. [14] XUE Li-jun, LI Zi-tian, LI Chang-le, et al(薛利军, 李自田, 李长乐, 等). Acta Photonica Sinica(光子学报), 2006, 35(6): 693. [15] HUANG Zhan-hua, YANG Ji-chun, ZHAO Tian-hong, et al(黄战华, 杨基春, 赵天虹, 等). Opto-Electronic Engineering(光电工程),2008, 35(3): 35. [16] Horman S R, Hepfer K C, Zurasky M W. Infrared Technology and Applications XXI,1996, 2744: 154. [17] Torres S N, Hayat M M. Journal of Opt. Soc. Am., 2003, 20(3): 470. [18] Harris J G, Chiang Y M. IEEE Transactions on Image Processing,1999, 8(8): 1148. [19] Schlapfer D, Kaiser J W, Brazile J, et al. Proc. SPIE, 2003,5234:22. [20] Roberts D A, Yamaguchi Y. In: Proceedings of the Nineteenth International Symposium on Remote Sensing of Environment, Michigan, 1985. 21.
|
[1] |
WANG Xin-qiang1,3, ZHANG Li-juan1,3, XIONG Wei2, ZHANG Wen-tao1,3, YE Song1,3, WANG Jie-jun1,3*. Study on Inhomogeneous Correction of Interference Pattern of Spatial Heterodyne Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37(04): 1274-1278. |
[2] |
XIE Pei-yue1, 2, YANG Jian-feng1, XUE Bin1*, Lü Juan1, HE Ying-hong1, LI Ting1, MA Xiao-long1 . Research on an Equal Wavelength Spectrum Reconstruction Method of Interference Imaging Spectrometer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(03): 848-852. |
[3] |
WANG Xiang1,2, CHEN Jian-ping1,2*, LI Jian-feng1,2, SHI Rui1,2, WU Zhao1,2 . Information Extraction of the Chang’E-1 Interference Imaging Spectrometer (IIM) 2C Data [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(04): 1145-1150. |
[4] |
TANG Yi, TANG Qiu-yan, WANG Xiao-yan, CAO Wei-liang, WANG Jing . Simulation and Analysis of Interference Imaging Spectrometer Influenced by Satellite Vibration[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(11): 3149-3153. |
[5] |
CHEN Chao, QIN Qi-ming*, ZHANG Ning, WANG Jin-liang, LI Jun, JIANG Hong-bo . Research on Photometric Calibration and Reflectance Calculation of CE-1 IIS Data[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(07): 1985-1990. |
[6] |
ZHANG Xiu-bao1, YUAN Yan1, JING Juan-juan2,3, SUN Cheng-ming1, WANG Qian1 . Spectral Discrimination Method Information Divergence Combined with Gradient Angle [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31(03): 853-857. |
[7] |
XIANGLI Bin1, Lü Qun-bo1, HUANG Min1, 3, YAO Tao2, 3 . Comparison of Two Types of Fourier Transform Imaging Spectrometry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30(05): 1422-1426. |
|
|
|
|