光谱学与光谱分析 |
|
|
|
|
|
Speciation Analysis of Selenium by Flow-Injection Catalytic Spectrophotometry |
FAN Jing, Lü Hui-xiong, YE Cun-ling,CUI Feng-ling |
School of Chemical and Environmental Sciences, Key Laboratory of Environmental Science and Engineering of Henan Education Department, Henan Normal University, Xinxiang 453002,China |
|
|
Abstract A new flow-injection catalytic spectrophotometric method was proposed for the determination of Se(Ⅳ) based on its catalytic effect on the reduction reaction of azure I by Na2S in pH 7.0 citric-acid sodium-hydrogen-phosphate buffer solution. Some different schematic diagrams of FIA were compared. Effects of the flow rates of reagents and sample, the medium and its acidity, the temperature, and coexistent substances were studied respectively. The amount of used reagents and the experimental conditions for sampling volume and coil length were optimized by using the controlled and weighed centroid simplex method. The Linear range of the determination is 0.1-2.0 mg·L-1, the detection limit is 0.015 mg·L-1, the relative standard deviation is less than 3.1%, and the sampling frequency is 120 samples per hour. The method has been applied to the determination of organic selenium and inorganic selenium in garlic and selenium-yeast. It was found that garlic had a strong enriching effect for selenium, and the conversion ratio of organic selenium decreased with increasing the concentration of selenium in the environment. The recovery of this method is 97.1%-104.3%.
|
Received: 2003-06-18
Accepted: 2003-10-26
|
|
Corresponding Authors:
FAN Jing
|
|
Cite this article: |
FAN Jing,Lü Hui-xiong,YE Cun-ling, et al. Speciation Analysis of Selenium by Flow-Injection Catalytic Spectrophotometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(02): 263-265.
|
|
|
|
URL: |
https://www.gpxygpfx.com/EN/Y2005/V25/I02/263 |
[1] QIU Pei-hong, LIN Li, YANG Xiao-feng(仇佩红, 林 丽, 杨小凤). Chinese J. of Anal. Chem.(分析化学), 2002, 30(8): 935. [2] LIU Chang-jiu, YANG Xi-qun, LIU Ji-sheng(刘长久, 杨细群, 刘继声). Chinese J. of Anal. Chem.(分析化学), 2001, 29(9): 1030. [3] Garifzyanov A R, Budnikov G K, Toropova V F et al. J. Anal. Chem., 2000, 55(7): 673. [4] CHEN Tian-yu,WANG Zheng(陈天裕, 汪 正). Chinese J. of Analysis Laboratory(分析试验室),2001,20(2):14. [5] QI Wen-bin,CHEN Xiao-mei(戚文彬, 陈笑梅). Chinese J. of Anal. Chem.(分析化学), 1991, 19(4): 433. [6] Lozano C M, Perez-Ruiz T, Tomas V et al. Analyst, 1989, 114(6): 715.
|
[1] |
ZHENG Pei-chao, ZHONG Chao, WANG Jin-mei*, LUO Yuan-jiang, LAI Chun-hong, WANG Xiao-fa, MAO Xue-feng. Evaluation of Flow Injection-Solution Cathode Glow Discharge With an Interference Filter Wheel for Spectral Discrimination[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(03): 842-847. |
[2] |
AN Xue-jing, LUO Yun-jing*, ZHANG Chen-yang. Research on the Reaction Dynamics between Peroxynitrite and Tyrosine Catalyzed with Mimic Enzyme through Flow Injection Analyzer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(12): 4052-4057. |
[3] |
LIU Bing-zhi1, LUO Zhi-yong2*, ZHENG Huai-li1, JIANG Lei2 . Study on the Catalytic Kinetic Spectrophotometric Determination of Trace Amounts of Iron(Ⅲ) and Its Reaction Mechanism [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36(04): 1139-1144. |
[4] |
LUO Zhi-yong1, ZHENG Huai-li2 . Determination of Trace Amounts of Nitrite and Its Chemical Reaction Kinetics[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34(06): 1619-1623. |
[5] |
HAN Bin1, CAO Lei1, 2, ZHENG Li1, ZANG Jia-ye1, WANG Xiao-ru1 . Flow Injection-Spectrophotometric Determination of Total Dissolved Nitrogen in Seawater Based on Quantificational Solenoid Valves[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32(01): 219-222. |
[6] |
ZHAO Zhen-yi,HAN Guang-xi,SONG Xi-ming,LUO Zhi-xiong. Determination of Aluminum in Sediments by Atomic Absorption Spectrophotometer without FIA Spectrophotometric Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28(06): 1413-1415. |
[7] |
MI Jian-ping1,LI Yuan-qian1*,ZOU Xiao-li1,ZHENG Bo1,YANG Jing-guo2 . Simultaneous Determination of Iron, Copper and Cobalt in Food Samples by Diode Array Detection-Flow Injection Analysis Using Partial Least Squares Calibration Model [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(06): 1188-1191. |
[8] |
LI Hua1, 2,ZHANG Xin-shen3*,ZOU Yu-quan3,XIE Yong-hong3. Study on a New Method for Determining Trace Amounts of Manganese(Ⅱ) in Water by Flow-Injection Catalytic Kinetic Spectrophotometry [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27(04): 785-788. |
[9] |
SONG Gui-lan, REN Hao, LI Guo-bao, YANG Lin. Determination of Trace Manganese by Catalytic Kinetic Spectrophotometry Method with CTMAB as the Sensitizer[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(08): 1536-1539. |
[10] |
ZI Yan-qin, LU Hao-miao. Study on Determination of Trace Nitrite and Reaction Mechanism by Two-Wavelength Negative Absorption-Catalytic Spectrophotometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(01): 137-139. |
[11] |
GUO Liang-qia, LIN Xu-cong, XIE Zeng-hong*, FU Yan-bin. Study on β-Cyclodexdrin Sensitizing Catalytic Kinetic Spectrophotometric Determination of Mn(Ⅱ) [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(10): 1662-1666. |
[12] |
YU Ping, GAO Jun-jie, SONG En-jun. Kinetic Spectrophotometric Determination of Trace Chromium(Ⅵ) with Sensitized Function of Microemulsion [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(10): 1674-1676. |
[13] |
LI Yuan-qian1, Lü Xing1, ZOU Xiao-li1, MI Jian-ping1, YANG Jing-guo2 . CCD-Array Detection-Flow Injection Analysis of Oligomeric Proanthocyanidins in Health Food[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(10): 1724-1726. |
[14] |
MA Hong-yan. Determination of Genyamicin Sulfate in Injections by Flow-Injection Electrogenerated Chemiluminescence [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(08): 1210-1212. |
[15] |
SUN Deng-ming,FANG Hua-cai. Determination of Trace Manganese by Non-Organic Solvents Extraction Catalytic Spectrophotometry in Mn(Ⅱ)-H2O2-EBT-PEG-2000 System [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25(08): 1315-1317. |
|
|
|
|