光谱学与光谱分析 |
|
|
|
|
|
Effect of Nebulizer Gas Pressure on the Emission Intensity of ICP |
CHEN Jin-zhong, HA Jing, WEI Yan-hong, GUO Qing-lin, HUAI Su-fang |
College of Physics Science and Technology, Hebei University, Baoding 071002, China |
|
|
Abstract In an attempt to inhance the emission intensity of ICP, a conventional concentric pneumatic nebulizer was used with increased pressure, and the aqueous aerosol was partially let out to modulate the flow velocity of sample solution into the flame of the ICP. In the present work, the emission spectra of elements Ca, Si, Sr and Zn in water samples were measured, and the results showed that corresponding emission intensities are the highest at 0.05 MPa under the conventional condition, and after increasing the nebulizer gas pressure to 0.07 MPa and letting out part of aqueous aerosol, the peak values grew by 38%, 79%, 45% and 70%, respectively. In addition, the stability of the plasma radiation was not affected by the higher nebulizer gas pressure.
|
Received: 2005-05-16
Accepted: 2005-08-26
|
|
Corresponding Authors:
CHEN Jin-zhong
|
|
Cite this article: |
CHEN Jin-zhong,HA Jing,WEI Yan-hong, et al. Effect of Nebulizer Gas Pressure on the Emission Intensity of ICP [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(09): 1707-1709.
|
|
|
|
URL: |
https://www.gpxygpfx.com/EN/Y2006/V26/I09/1707 |
[1] He Zhi Zhuang, Barnes R M. Spectrochim. Acta, 1985, 40B(1/2): 11. [2] Schaldach, G, Berger L, Razilov I. Sperctrchim. Acta, 2002, 57B(10): 1505. [3] Civaldi C J, Vollmer J, Slavin W. Spectrochim. Acta, 1991, 46B(6/7): 1063. [4] Conver T S, Koropckak J A. Sperctrchim. Acta, 1995, 50B(4-7): 341. [5] Ari Vinen, Reijo S, Janne S. Anal. Bioanal. Chem., 2002, 373(3): 93. [6] Mcgeorge S W, Salin E D. Appl. Spectrosc., 1985, 39(6): 989. [7] Cicerone M T, Farnsworth P B. Sperctrchim. Acta, 1989, 44B(9): 897. [8] Lü Jie(吕 杰). Spectroscopy and Spectral Analysis(光谱学与光谱分析),2003,23(4):779. [9] Barnes R M, Schleicher R G. Spectrochim. Acta, 1981, 36B(2): 81. [10] Barnes R M, Genna J L. Spectrochim. Acta, 1981, 36B(4): 299. |
[1] |
ZHANG Yu-hui1, 2, DING Yong-kang3, PEI Jing-cheng1, 2*, GU Yi-lu1, 2, YU Min-da1, 2. Chemical Constituents and Spectra Characterization of Monocrystal
Rhodonite From Brazil[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3504-3508. |
[2] |
SUN Da-wei1, 2, 3, DENG Jun1, 2*, JI Bing-bing4. Study on the Preparation Mechanism of Steel Slag-Based Biomass Activated Carbon by Special Steel Slag-Discard Walnut Shells Based on ICP-MS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(07): 2308-2312. |
[3] |
BI Yan-qi1, 2 , YANG Ying-dong3, DU Jing4, TANG Xiang5, LUO Wu-gan1, 2*. A Study on Mineral Material Sources of Multi-Style Bronzes Collected by Cultural Relic Administration Center of Huili County, Sichuan Province With MC-ICP-MS[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1140-1146. |
[4] |
WANG Zi-min1, MAO Xiao-tian1, YIN Zuo-wei1*, CHEN Chang2, CHENG Tian-jia1. Study on the Spectral Characteristics and the Color-Change Effect of Spinel[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(11): 3541-3545. |
[5] |
JUMAHONG Yilizhati1, 2, TAN Xi-juan1, 2*, LIANG Ting1, 2, ZHOU Yi1, 2. Determination of Heavy Metals and Rare Earth Elements in Bottom Ash of Waste Incineration by ICP-MS With High-Pressure Closed
Digestion Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(10): 3168-3173. |
[6] |
CHEN Xiao-li1, WANG Li-chun1, LI You-li1, GUO Wen-zhong1, 2*. Effects of Alternating Light Spectrum on the Mineral Element Level of Lettuce[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(09): 2813-2817. |
[7] |
LUO Heng, Andy Hsitien Shen*. Based on Color Calculation and In-Situ Element Analyze to Study the Color Origin of Purple Chalcedony[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(06): 1891-1898. |
[8] |
YANG Yan-ling1, Andy Hsitien Shen1, FAN Yu-rong2, HUANG Wei-zhi1, PEI Jing-cheng1*. UV-Vis-NIR Spectroscopic Characteristics of Vanadium-Rich
Hydrothermal Synthetic Emeralds From Russia[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(04): 1199-1203. |
[9] |
ZHONG Yuan, QU Meng-wen, Andy Hsitien Shen*. Comparison of Chemical Composition and Spectroscopy of Purple- Brownish Red Garnet From Zambia, Tanzania and Australia[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(01): 184-190. |
[10] |
DU Jing1,JIN Tao2, HU Feng-dan1, ZHANG Chi1, ZHU Tie-quan3, ZHAN Chang-fa3, LI Nai-sheng1, JIA Zheng1, CHEN Yue1*. Desalination Monitoring of Wooden Shipwreck Components of the Qing Dynasty Marine Shipwreck,Xiaobaijiao No.1[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(10): 3294-3298. |
[11] |
ZHANG Bin-bin1, 2, LI Jing-bin1, 2, WANG Shi-ning1, 2, HE Peng-fei1, 2, ZHA Xiao-qin1, 2, 3. Determination of Lithium, Iron and Phosphorus in Carbon Composite Lithium Iron Phosphate by Perchloric Acid Digestion-Inductively Coupled Plasma Optical Emission Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(09): 2703-2709. |
[12] |
LIAN Xiao-qin1, 2,LIU Yu1, 2,CHEN Yan-ming1, 2,HUANG Jing1, 2,GONG Yong-gang1, 2,HUO Liang-sheng1, 2. Research on Multi-Peak Spectral Line Separation Method Based on Adaptive Particle Swarm Optimization[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(05): 1452-1457. |
[13] |
ZHAO Ting1,2,3, CHI Hai-tao1,2,3*, LIU Yi-ren1,2,3, GAO Xia1,2,3, HUANG Zhao1,2,3, ZHANG Mei1,2,3, LI Qin-mei1,2,3. Determination of Elements in Health Food by X-Ray Fluorescence Microanalysis Combined With Inductively Coupled Plasma Mass Spectrometry[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41(03): 750-754. |
[14] |
LIU Wei-yi, MENG Yuan, JIN Bai-chuan, JIANG Meng-yun, LIN Zu-hong, HU Li-yang, ZHANG Ting-ting*. Distribution Characteristics and Ecological Risk Assessment of Heavy Metals in Surface Sediments of the North Canal Using ICP-OES[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(12): 3912-3918. |
[15] |
WANG Nian1,2, SHEN Hua1,2*, ZHU Ri-hong1,2. Spectral Radiation Transmission Model of Plasma in Laser Welding[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40(05): 1362-1366. |
|
|
|
|