光谱学与光谱分析 |
|
|
|
|
|
Application of Immunomagnetic Separation to E.coli O157∶H7 Detection |
TANG Qian-qian, WANG Jian-ping*, YE Zun-zhong, GAI Ling, YING Yi-bin |
College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310029, China |
|
|
Abstract In the present paper, the capture efficiencies of four different proportions of E.coli O157∶H7 and immunomagnetic beads (IMB) (1∶6.34, 1∶12.69, 1∶25.38 and 1∶30.07) and three different proportions of E.coli O157∶H7 and Bacillus subtilis(0.3 mL∶0.1 mL, 0.2 mL∶0.2 mL and 0.1 mL∶0.3 mL)were compared, with the total volume and capacity of IMB remaining constant. It was revealed that the capture efficiency could reach 100% when the proportion of E.coli O157∶H7 and IMB was 1∶30, meaning that almost all targets E.coli O157∶H7 could be captured at 1∶30, and that the capture efficiency decreased and then increased with the number of Bacillus subtilis increasing. Moreover, the combination of ATP bioluminescence and IMS was correlated well with conventional culture methods, R2=0.988 2, and the detection limit was as low as 102 CFU·mL-1.
|
Received: 2008-06-12
Accepted: 2008-09-16
|
|
Corresponding Authors:
WANG Jian-ping
E-mail: jpwang@zju.edu.cn
|
|
[1] Peter T Kissinger. Biosensors and Bioelectronics, 2005, 20: 2512. [2] Tokarskyy O, Marshall D L. J. Food Microbial., 2007, 7:005. [3] Lazcka O, Campo F J D, Munoz F X. Biosensors and Bioelectronics, 2007, 22: 1205. [4] Su X, Li Y. Anal. Chem., 2004, 76: 4806. [5] Yang L, Li Y, Erf G. Anal. Chem., 2004, 76: 1107. [6] YANG Dong-zhi, XU Shu-kun, CHEN Qi-fan(杨冬芝,徐淑坤,陈启凡). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2007, 27(9): 1807. [7] Olsvik Q, Popovic T, Skjerve E, et al. Clinical Microbiology Reviews, 1994, 7(1): 43. [8] Velasco-Garcia M N, Mottram T. Biosystems Engineering, 2003, 84: 1. [9] Lee Jiyoung, et al. Luminescence, 2004, 19: 31. [10] Watarai M, Yamato Y, Murakata K, et al. Journal of Veterinary Medical Science, 2005, 67: 449. [11] Squirrell D J, Murphy M J, et al. Analytica Chimica Acta,2002, 457: 109. [12] Yu L S L, Reed S A, Golden M H. J. Microbiological Methods, 2002, 49: 63. [13] HUANG Qi-yu(黄其宇). Chinese Journal of Medical Laboratory Technology(中国医学检验杂志),2001,2(3):203. [14] Varshney M, Li Y. Biosensors and Bioelectronics, 2007, 22: 2408. [15] LIU Bing-zhi, ZHU Bei(刘炳智,朱 蓓). J. of Preventive Medicine Information(预防医学情报杂志),1999,15(1): 29. [16] McElroy W D. Methods in Enzymology, 1963, 6: 445. [17] LI Zhi-pei, MIAO Li(李志培,苗 丽). China Food Industry(中国食品工业),2004, 12:58.
|
|
|
|