光谱学与光谱分析 |
|
|
|
|
|
The Calibration of Instrument Response Function during Passive FTIR Measurement |
ZHANG Li-ming1, ZHANG Lin1, LI Yan1*, WANG Xiao-fei1,2, LIU Bing-ping1,3, REN Yi-bo1, WANG Jun-de1 |
1. Laboratory of Advanced Spectroscopy, Nanjing University of Science and Technology, Nanjing 210014, China 2. Department of Chemistry, Nanjing University, Nanjing 210093, China 3. Department of Chemistry, Qufu Normal University, Qufu 273165, China |
|
|
Abstract In order to obtain infrared spectral radiance distribution of some infrared sources, such as spectral radiant flux density, spectral radiant intensity, spectral radiance and spectral irradiance, the instrument response function under different conditions must be known. In the present paper, the calibration of instrument response function during passive FTIR measurement has been discussed. The experimental results illustrate that under different experimental conditions, the instrument response function varies not only with the temperature of the blackbody but also with the signal amplitude received by the infrared instrument. So, during passive FTIR measurement, the temperature and the emission signal amplitude of the source must be observed carefully in order to get satisfactory instrument response function.
|
Received: 2004-10-09
Accepted: 2005-02-24
|
|
Corresponding Authors:
LI Yan
|
|
Cite this article: |
ZHANG Li-ming,ZHANG Lin,LI Yan, et al. The Calibration of Instrument Response Function during Passive FTIR Measurement[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2006, 26(01): 45-46.
|
|
|
|
URL: |
https://www.gpxygpfx.com/EN/Y2006/V26/I01/45 |
[1] Hilton M, Lettington A H, Mills I M. SPIE, 1994, 2089: 314. [2] Harig R, Matz G. Field Anal. Chem. Technol., 2001, 5(1-2): 75. [3] HUANG Zhong-hua(黄中华). The Application of Remote Sensing FTIR in Toxic Organic Compounds Measurement[PhD. Thesis]. Nanjing:Nanjing University of Sci & Tech(南京:南京理工大学),2003. [4] Tilotta D C, Busch K W, Busch M A. Appl. Spectrosc., 1989, 43(4): 704. [5] HUANG Zhong-hua, LI Yan, WANG Jun-de, CHEN Zuo-ru(黄中华,李 燕,王俊德,陈作如). Spectroscopy and Spectral Analysis(光谱学与光谱分析), 2002, 22(3): 399. [6] Wang Junde, Wang Tianshu, Chen Zouru, et al. Spectrosc. Lett., 1997, 30(4): 783.
|
[1] |
LIN Hong-jian1, ZHAI Juan1*, LAI Wan-chang1, ZENG Chen-hao1, 2, ZHAO Zi-qi1, SHI Jie1, ZHOU Jin-ge1. Determination of Mn, Co, Ni in Ternary Cathode Materials With
Homologous Correction EDXRF Analysis[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3436-3444. |
[2] |
HUANG Meng-qiang1, KUANG Wen-jian2, 3*, LIU Xiang1, HE Liang4. Quantitative Analysis of Cotton/Polyester/Wool Blended Fiber Content by Near-Infrared Spectroscopy Based on 1D-CNN[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(11): 3565-3570. |
[3] |
CHAI Shu1, PENG Hai-meng1, WU Wen-dong1, 2*. Acoustic-Based Spectral Correction Method for Laser-Induced Breakdown Spectroscopy in High Temperature Environment[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(05): 1401-1407. |
[4] |
JIANG Jun1, 2, YAO Zhi-gang1, 2*. Dynamic Detection and Correction for Abnormal Response of CCD Pixels in Spaceborne Low-Light Imager[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(04): 1175-1182. |
[5] |
ZHANG Le-wen1, 2, WANG Qian-jin1, 3, SUN Peng-shuai1, PANG Tao1, WU Bian1, XIA Hua1, ZHANG Zhi-rong1, 3, 4, 5*. Analysis of Interference Factors and Study of Temperature Correction Method in Gas Detection by Laser Absorption Spectroscopy[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(03): 767-773. |
[6] |
HU Xiao-yun1, BIAN Xi-hui1, 2, 3*, XIANG Yang2, ZHANG Huan1, WEI Jun-fu1. Quantitative Analysis of Single Component Oils in Quinary Blend Oil by Near-Infrared Spectroscopy Combined With Chemometrics[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(01): 78-84. |
[7] |
ZHU Chen-guang1, LIU Ya-jun2, LI Xin-xing1, 3, GONG Wei-wei4*, GUO Wei1. Detection Method of Freshness of Penaeus Vannamei Based on
Hyperspectral[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(01): 107-110. |
[8] |
CHEN Yong1, 2, GUO Yun-zhu1, WANG Wei3*, WU Xiao-hong1, 2*, JIA Hong-wen4, WU Bin4. Clustering Analysis of FTIR Spectra Using Fuzzy K-Harmonic-Kohonen Clustering Network[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(01): 268-272. |
[9] |
LIAN Xiao-qin1, 2, CHEN Yan-ming1, 2, WANG Yu-qiao1, 2, LIU Yu1, 2. Research on ICP-AES Spectral Baseline Correction Method Based on DE Algorithm and NURBS Curve[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43(01): 260-267. |
[10] |
CHEN Su-yi, LI Hao-ran, DAI Ji-sheng*. Baseline Correction Method Based on Block Sparse Signal Recovery[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(12): 3730-3735. |
[11] |
HE Nian, SHAN Peng*, HE Zhong-hai, WANG Qiao-yun, LI Zhi-gang, WU Zhui. Study on the Fractional Baseline Correction Method of ATR-FTIR
Spectral Signal in the Fermentation Process of Sodium Glutamate[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(06): 1848-1854. |
[12] |
SUN Hua-sheng1, ZHANG Yuan2*, SHI Yun-fei1, ZHAO Min1. A New Method for Direct Measurement of Land Surface Reflectance With UAV-Based Multispectral Cameras[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(05): 1581-1587. |
[13] |
CHENG Jie-hong1, CHEN Zheng-guang1, 2*, YI Shu-juan2. Wavelength Selection Algorithm Based on Minimum Correlation Coefficient for Multivariate Calibration[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(03): 719-725. |
[14] |
SUN Zhi-xing, ZHAO Zhong-gai*, LIU Fei. Near-Infrared Spectral Modeling Based on Stacked Supervised Auto-Encoder[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(03): 749-756. |
[15] |
XIE Lin-jiang, HONG Ming-jian*, YU Zhi-rong. A Wavelength Selection Method Combining Direct Orthogonal Signal Correction and Monte Carlo[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42(02): 440-445. |
|
|
|
|